4.4.4.
Battery Low/Power Down Detector
Circuit Operation:
“Battery Low” and “Power Down” are detected by BBIC which check the voltage from battery.
The detected voltage is as follows;
• Battery Low
Battery voltage: V(Batt) 2.25 V ± 50 mV
The BBIC detects this level and "
" starts flashing.
• Power Down
Battery voltage: V(Batt) 2.0 V ± 50 mV
The BBIC detects this level and power down.
4.4.5.
Speakerphone
The hands-free loudspeaker at SP+ and SP- is used to generate the ring alarm.
4.5.
Block Diagram (Charger Unit)
Charger Terminal
AC Adaptor