32
KX-TG6511TRB/KX-TG6511TRM/KX-TGA650EXB/KX-TGA650EXM/KX-TGA651EXB/KX-TGA651EXM
9.1.4.3.
Check Table for RF part
Note:
(*1) Refer to
Adjustment Standard (Base Unit)
(*2) Refer to
No.
Item
BU (Base Unit) Check
HS (Handset) Check
1
Link Confirmation Normal
HS, BU Mode: [Normal mode]
1. Register Regular HS to BU (to be
checked).
2. Press [Talk] key of the Regular HS to
establish link.
1. Register HS (to be checked) to Regular
BU.
2. Press [Talk] key of the HS to establish link.
2
X’tal Frequency confirmation
1. Check X’tal Frequency. (*1)
(10.368 MHz ± 100 Hz)
1. Check X’tal Frequency. (*2)
(10.368 MHz ±100Hz)
3
Range Confirmation Normal
HS, BU Mode: [Normal mode]
1. Register Regular HS to BU (to be
checked).
2. Press [Talk] key of the Regular HS to
establish link.
3. Compare the range of the BU (being
checked) with that of the Regular BU.
1. Register HS (to be checked) to Regular
BU.
2. Press [Talk] key of the HS to establish link.
3. Compare the range of the HS (being
checked) with that of the Regular HS.
Содержание KX-TG6511TRB
Страница 2: ...2 KX TG6511TRB KX TG6511TRM KX TGA650EXB KX TGA650EXM KX TGA651EXB KX TGA651EXM ...
Страница 14: ...14 KX TG6511TRB KX TG6511TRM KX TGA650EXB KX TGA650EXM KX TGA651EXB KX TGA651EXM 4 6 Signal Route ...
Страница 18: ...18 KX TG6511TRB KX TG6511TRM KX TGA650EXB KX TGA650EXM KX TGA651EXB KX TGA651EXM 8 1 2 Handset ...
Страница 44: ...44 KX TG6511TRB KX TG6511TRM KX TGA650EXB KX TGA650EXM KX TGA651EXB KX TGA651EXM 10 1 2 Handset ...
Страница 45: ...45 KX TG6511TRB KX TG6511TRM KX TGA650EXB KX TGA650EXM KX TGA651EXB KX TGA651EXM 10 1 3 Charger Unit ...
Страница 77: ...77 KX TG6511TRB KX TG6511TRM KX TGA650EXB KX TGA650EXM KX TGA651EXB KX TGA651EXM 15 4 Accessories ...