58
KX-TG5521RUB/KX-TGA551RUB
11.8. RF Specification
11.8.1. Base Unit
*: Refer to
Check Point (Base Unit)
(P.36)
11.8.2. Handset
**: Refer to
Check Point (Handset)
(P.40)
Item
Value
Refer to -. *
TX Power
19 dBm ~ 25 dBm
Check Point (Base Unit) (J)
Modulation
-370±30/+370±30 kHz/div & Modulated
width
690
kHz
Check Point (Base Unit) (K)
Frequency Offset
-50 kHz ~ +50 kHz
Check Point (Base Unit) (L)
Frequency Drift
< ± 35 kHz / ms
Check Point (Base Unit) (M)
RX Sensitivity
< 1000 ppm
Check Point (Base Unit) (N)
Timing Accuracy
< ± 5.0 ppm/<±15.0ppm
Check Point (Base Unit) (O)
Power RAMP
Power RAMP is matching
Check Point (Base Unit) (P)
Item
Value
Refer to -. **
TX Power
19 dBm ~ 25 dBm
Check Point (Handset) (I)
Modulation
-370±30/+370±30 kHz/div & Modulated
width
690
kHz
Check Point (Handset) (J)
Frequency Offset
-50 kHz ~ +50 kHz
Check Point (Handset) (K)
Frequency Drift
< ± 35 kHz / ms
Check Point (Handset) (L)
RX Sensitivity
< 1000 ppm
Check Point (Handset) (M)
Power RAMP
Power RAMP is matching
Check Point (Handset) (N)