11.5. The Setting Method of JIG (Handset)
This section explains the PC setting to use command required in
Check Point (Handset)(
P.39).
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
•
Batch file CD-ROM
for setting: PNZZTG2511CA
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
11.5.1. Connections
Connect the DC Power or Battery to BATT+ and BATT-.
Connect the JIG cable GND (black) to GND.
Connect the JIG cable UTX (yellow) to UTX and URX (red) to URX.
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
Ω
)
New value (k
Ω
)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
Содержание KX-TG2511CAM
Страница 2: ...2 KX TG2511CA KX TG2512CA KX TGA250RU ...
Страница 14: ...14 KX TG2511CA KX TG2512CA KX TGA250RU 4 6 Signal Route ...
Страница 16: ...16 KX TG2511CA KX TG2512CA KX TGA250RU 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Страница 18: ...18 KX TG2511CA KX TG2512CA KX TGA250RU 8 1 2 Handset ...
Страница 27: ...27 KX TG2511CA KX TG2512CA KX TGA250RU Cross Reference Check Point Base Unit P 35 ...
Страница 29: ...29 KX TG2511CA KX TG2512CA KX TGA250RU Cross Reference Check Point Handset P 39 ...
Страница 44: ...44 KX TG2511CA KX TG2512CA KX TGA250RU 10 1 2 Handset ...
Страница 45: ...45 KX TG2511CA KX TG2512CA KX TGA250RU 10 1 3 Charger Unit ...
Страница 77: ...77 KX TG2511CA KX TG2512CA KX TGA250RU 15 4 Accessories A2 A1 ...