7.3.3.
Check Table for RF part
No.
Item
BU checking
HS checking
1a Link confirmation Normal
1. Re-resister HS Regular Unit (working) to BU.
2. Press [Talk] key ofthe HS Regular Unit to
establish link.
1. Re-resister HS to BU ofRegular Unit (working).
2. Press [Talk] key ofthe HS to establish link.
1b Link confirmation TX Test
1. Re-resister HS Regular Unit (working) to BU.
2. Set BU to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:High)
3. Set HS Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:Low)
4. Press [1] key ofHS Regular Unit to establish link
about 5m away from BU.
5. Press [1] key ofHS Regular Unit to set RSSI
mode, and press [2] key to set RX Gain Low.
6. Confirm the value of RSSI in LCD of HS Regular
Unit is more than “e0(hex)”.
1. Re-resister HS to BU Regular Unit (working).
2. Set BU Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:Low)
3. Set HS to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:High)
4. Press [1] key ofHS to establish link about 5m
away from BU of Regular Unit.
5. Press [1] key ofBU Regular Unit to set RSSI
mode, and press [2] key to set RX Gain Low.
6. Confirm the value of RSSI in LCD of BU Regular
Unit is more than “e0(hex)”.
1c Link confirmation RX Test 1. Re-resister HS Regular Unit (working) to BU.
2. Set BU to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:Low)
3. Set HS Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:High)
4. Press [1] key ofHS Regular Unit to establish link
about 5m away from BU.
5. Press [1] key ofBU to set RSSI mode, and press
[2] key to set RX Gain Low.
6. Confirm the value of RSSI in LCD of BU is more
than “e0(hex)”.
1. Re-resister HS to BU ofRegular Unit (working).
2. Set BU Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:High)
3. Set HS to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:Low)
4. Press [1] key ofHS to establish link about 5m
away from BU Regular Unit.
5. Press [1] key ofHS to set RSSI mode, and press
[2] key to set RX Gain Low.
6. Confirm the value of RSSI in LCD of HS is more
than “e0(hex)”.
2
Control signal confirmation 1. Set TX Burst mode.(*1)
2. Check DSP interface.(*2)
1. Set TX Burst mode.(*1)
2. Check DSP interface.(*2)
3
X’tal Frequency
confirmation (*5)
1. Adjust X’tal mode.(*1)
2. Check X’tal Frequency.
(13.824000MHz±100Hz)
1. Adjust X’tal mode.(*1)
2. Check X’tal Frequency.
(13.824000MHz±100Hz)
4
TX Power confirmation
1. Set BU to TX Burst mode at 45ch. (*1)
(TX Power:High)
2. Set HS Regular Unit to RX-CW TEST mode at
45ch (RX Gain is fixed Low Gain). (*1)
3. Place HS Regular Unit about 5m away from BU.
4. Confirm RSSI of HS Regular Unit is more than
1.75V by Oscilloscope.(*4)
1. Set HS to TX Burst mode at 45ch. (*1)
(TX Power:High)
2. Set BU Regular Unit to RX-CW TEST mode at
45ch (RX Gain is fixed Low Gain). (*1)
3. Place HS about 5m away from BU Regular Unit.
4. Confirm RSSI of BU Regular Unit is more than
1.75V by Oscilloscope.(*3)
5
RX Sensitivity confirmation 1. Set BU to RX-CW TEST mode at 45ch (RX Gain
is fixed Low Gain). (*1)
2. Set HS Regular Unit to TX Burst mode at 45ch.
(*1) (TX Power:High)
3. Place HS Regular Unit about 5m away from BU.
4. Confirm RSSI of BU is more than 1.75V by
Oscilloscope.(*3)
1. Set HS to RX-CW TEST mode at 45ch (RX Gain
is fixed Low Gain). (*1)
2. Set BU Regular Unit to TX Burst mode at 45ch.
(*1) (TX Power:High)
3. Place HS about 5m away from BU Regular Unit.
4. Confirm RSSI of HS is more than 1.75V by
Oscilloscope.(*4)
Note:
(*1)
ADJUSTMENT AND TEST MODE
(P.29)
(*2)
RF-DSP interface signal wave form
(P.27)
(*3)
CIRCUIT BOARD (BASE UNIT) Component View
(P.89)
(*4)
CIRCUIT BOARD (HANDSET) Component View
(P.91)
(*5)
X801 (Base Unit), X201 (Handset) Check
(P.37)
26
KX-TG2480BXS / KX-TGA248BXS
Содержание KX-TG2480BXS
Страница 7: ...4 1 5 Battery Replacement 4 1 6 Battery Performance 7 KX TG2480BXS KX TGA248BXS ...
Страница 8: ...4 2 Location of Controls 4 2 1 Base unit 4 2 2 Handset 8 KX TG2480BXS KX TGA248BXS ...
Страница 10: ...4 4 Settings 4 4 1 Connections 4 4 1 1 Connecting the AC Adaptor 10 KX TG2480BXS KX TGA248BXS ...
Страница 11: ...4 4 1 2 Connecting the Telephone Line Cord 11 KX TG2480BXS KX TGA248BXS ...
Страница 12: ...12 KX TG2480BXS KX TGA248BXS ...
Страница 13: ...4 4 2 Guide to Handset Programming 13 KX TG2480BXS KX TGA248BXS ...
Страница 15: ...4 4 4 Direct Commands 15 KX TG2480BXS KX TGA248BXS ...
Страница 17: ...17 KX TG2480BXS KX TGA248BXS ...
Страница 18: ...18 KX TG2480BXS KX TGA248BXS ...
Страница 21: ...6 ASSEMBLY INSTRUCTIONS 6 1 Fix the LCD to P C Board Handset 21 KX TG2480BXS KX TGA248BXS ...
Страница 27: ...7 3 4 RF DSP interface signal wave form 27 KX TG2480BXS KX TGA248BXS ...
Страница 66: ...17 SIGNAL ROUTE Each signal route is as follows 66 KX TG2480BXS KX TGA248BXS ...
Страница 69: ...20 EXPLANATION OF IC TERMINALS RF UNIT 20 1 IC901 69 KX TG2480BXS KX TGA248BXS ...
Страница 72: ...22 CABINET AND ELECTRICAL PARTS BASE UNIT 72 KX TG2480BXS KX TGA248BXS ...
Страница 73: ...23 CABINET AND ELECTRICAL PARTS HANDSET 73 KX TG2480BXS KX TGA248BXS ...
Страница 74: ...24 ACCESSORIES AND PACKING MATERIALS 74 KX TG2480BXS KX TGA248BXS ...
Страница 75: ...25 TERMINAL GUIDE OF THE ICs TRANSISTORS AND DIODES 25 1 Base Unit 25 2 Handset 75 KX TG2480BXS KX TGA248BXS ...
Страница 82: ...Memo 82 KX TG2480BXS KX TGA248BXS ...
Страница 94: ...94 KX TG2480BXS KX TGA248BXS H M N KXTG2480BXS KXTGA248BXS ...