8.3. X501 (Base Unit), X201 (Handset) Check
Equipment: Frequency counter
Check Point for measurement: BCK
Checking tolerance: 13.824MHz ± 100Hz (Base Unit)/13.824MHz ± 100Hz (Handset)
8.3.1. Check and Adjust X501 (Base Unit) Frequency
1. Set up Base Unit in TEST mode.
2. Press following keys in order to Adjust Crystal mode. [LOCATOR], [LOCATOR], [LOCATOR], [Button 1] (*1), [Button 2] (*1),
[Button 2] (*1), [Button 1] (*1). Check BCK frequency.
3. If the BCK frequency is out of the checking tolerance (± 100Hz), adjust to Adjustment tolelance (± 30Hz) by pressing [Button
1] (*1) or [Button 2] (*1) key.
Adjustment Tolerance: 13.824MHz ± 30Hz
4. Press [LOCATOR] key to write the new frequency factor in Memory.
5. Turn the power off. Then this value is available.
Note:
(*1) When you check test mode, connect to the external Buttons because Base Unit has only LOCATOR key. Refer to “For Test
Mode” in
Base Unit Reference Drawing
(P.40). -Insert AC adaptor during checking.
Cross Reference:
Adjustment Mode
(P.34)
8.3.2. Check and Adjust X201 (Handset) Frequency
1. Set DC power supply to 2.6V.
2. Set up Handset in TEST mode (Adjustment flow).
3. Press [1] key to Adjust Crystal mode. (“Clock Adj.” is displayed on LCD). Check BCK frequency.
4. If the BCK frequency is out of the checking tolerance (± 100Hz), adjust to Adjustment tolelance (± 30Hz) by pressing [ ] or [ ]
key.
Adjustment Tolerance: 13.824MHz ± 30Hz
5. Press [TALK] key to write the new frequency factor in EEPROM.
6. Turn the power off. Then this value is available.
Cross Reference:
Adjustment Mode
(P.38)
8.4. Adjust Battery Low Detector Voltage (Handset)
After Handset´s DSP (IC201) or EEPROM (IC241) replacement, Re-writing Battery Low voltage to EEPROM is required.
With following Handset Adjustment Flow, adjust DC power supply and DC voltmeter by the procedure below.
1. Set DC power supply to 2.6V.
2. Set up Handset in TEST mode (Adjustment flow).
3. Press [1] key and [OFF] key to Adjust Batt Low mode. (“Bat Adj.” is displayed on LCD)
4. Change the voltage of the DC power supply to 2.33V accurately. Check the voltage at P.C. board pads because some voltage
drops occur due to the usage of long or thin cables.
5. Press [TALK] key to write voltage value in EEPROM.
6. Turn the power off. Then this value is available.
Note:
Refer to
Handset Reference Drawing
(P.41) for connection of DC power supply and voltmeter.
Cross Reference:
Adjustment Mode
(P.38)
39
KX-TG2448BXF / KX-TG2448B XS / KX-TGA254BXF / KX-TGA254BXS
Содержание KX-TG2448BXF
Страница 10: ...4 4 Settings 4 4 1 Connections 10 KX TG2448BXF KX TG2448BXS KX TGA254BXF KX TGA254BXS ...
Страница 11: ...4 4 2 Guide to Handset Programming 11 KX TG2448BXF KX TG2448BXS KX TGA254BXF KX TGA254BXS ...
Страница 13: ...4 4 4 Direct Commands 13 KX TG2448BXF KX TG2448BXS KX TGA254BXF KX TGA254BXS ...
Страница 15: ...15 KX TG2448BXF KX TG2448BXS KX TGA254BXF KX TGA254BXS ...
Страница 16: ...16 KX TG2448BXF KX TG2448BXS KX TGA254BXF KX TGA254BXS ...
Страница 19: ...6 HOW TO REPLACE THE HANDSET LCD 19 KX TG2448BXF KX TG2448BXS KX TGA254BXF KX TGA254BXS ...
Страница 22: ...Note DSP is IC501 7 2 Check Battery Charge 22 KX TG2448BXF KX TG2448BXS KX TGA254BXF KX TGA254BXS ...
Страница 28: ...7 4 5 RF DSP Interface Signal Wave Form Test Burst Mode 28 KX TG2448BXF KX TG2448BXS KX TGA254BXF KX TGA254BXS ...
Страница 29: ... Test Burst Mode 29 KX TG2448BXF KX TG2448BXS KX TGA254BXF KX TGA254BXS ...
Страница 68: ...20 EXPLANATION OF IC TERMINALS RF PART 20 1 IC901 68 KX TG2448BXF KX TG2448BXS KX TGA254BXF KX TGA254BXS ...
Страница 71: ...22 CABINET AND ELECTRICAL PARTS BASE UNIT 71 KX TG2448BXF KX TG2448BXS KX TGA254BXF KX TGA254BXS ...
Страница 80: ...Memo 80 KX TG2448BXF KX TG2448BXS KX TGA254BXF KX TGA254BXS ...
Страница 94: ...Memo KX TG2448BXF KX TG2448BXS KX TGA254BXF KX TGA254BXS 94 ...
Страница 98: ...98 KX TG2448BXF KX TG2448BXS KX TGA254BXF KX TGA254BXS G N KXTG2448BXF KXTG2448BXS KXTGA254BXF KXTGA254BXS ...