41
KX-TG1034B/KX-TG1035S/KX-TGA101B/KX-TGA101S
9.1.4.4.
TEST RANGE Check
Circuit block which range is defective can be found by the following check.
CHART1: Setting of TX Power and RX Sensitivity in Range Confirmation TX TEST, RX TEST
Note:
(*1) Refer to
Commands
(P.57) for Base unit, and refer to
Commands
(P.62) for Handset.
Item
BU (Base Unit) Check
HS (Handset) Check
Range Confirmation TX TEST
(TX Power check)
HS, BU setting
Checked unit: Low TX power (*1)
Regular unit: High TX power (*1)
1. Register Regular HS to BU (to be checked).
2. Set TX Power of the BU and the Regular HS
according to CHART1.
3. At distance of about 20m between HS and BU,
Link OK = TX Power of the BU is OK.
No Link = TX Power of the BU is NG.
1. Register HS (to be checked) to Regular BU.
2. Set TX Power of the HS and the Regular BU
according to CHART1.
3. At distance of about 20m between HS and BU,
Link OK = TX Power of the HS is OK.
No Link = TX Power of the HS is NG.
Range Confirmation RX TEST
(RX sensitivity check)
HS, BU setting
Checked unit: High TX power (*1)
Regular unit: Low TX power (*1)
1. Register Regular HS to BU (to be checked).
2. Set TX Power of the BU and the Regular HS
according to CHART1.
3. At distance of about 20m between HS and BU,
Link OK= RX Sensitivity of the BU is OK.
No Link = RX Sensitivity of the BU is NG.
1. Register HS (to be checked) to Regular BU.
2. Set TX Power of the Checking HS and the Reg-
ular BU according to CHART1.
3. At distance of about 20m between HS and BU,
Link OK= RX Sensitivity of the HS is OK.
No Link = RX Sensitivity of the HS is NG
BU (to be checked)
Regular_HS
TX Power
TX Power
BU (Base Unit) TX Power Check
Low
High
BU (Base Unit) RX Sensitivity Check
High
Low
HS (to be checked)
Regular_BU
TX Power
TX Power
HS (Handset) TX Power Check
Low
High
HS (Handset) RX Sensitivity Check
High
Low
Содержание KX-TG1034B
Страница 2: ...2 KX TG1034B KX TG1035S KX TGA101B KX TGA101S ...
Страница 13: ...13 KX TG1034B KX TG1035S KX TGA101B KX TGA101S 4 6 Signal Route ...
Страница 14: ...14 KX TG1034B KX TG1035S KX TGA101B KX TGA101S ...
Страница 18: ...18 KX TG1034B KX TG1035S KX TGA101B KX TGA101S 7 Operation Instructions 7 1 Programmable Settings ...
Страница 19: ...19 KX TG1034B KX TG1035S KX TGA101B KX TGA101S ...
Страница 21: ...21 KX TG1034B KX TG1035S KX TGA101B KX TGA101S 7 4 Error Messages ...
Страница 22: ...22 KX TG1034B KX TG1035S KX TGA101B KX TGA101S 7 5 Troubleshooting ...
Страница 23: ...23 KX TG1034B KX TG1035S KX TGA101B KX TGA101S ...
Страница 24: ...24 KX TG1034B KX TG1035S KX TGA101B KX TGA101S ...
Страница 25: ...25 KX TG1034B KX TG1035S KX TGA101B KX TGA101S ...
Страница 26: ...26 KX TG1034B KX TG1035S KX TGA101B KX TGA101S 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Страница 28: ...28 KX TG1034B KX TG1035S KX TGA101B KX TGA101S 8 1 2 Handset ...
Страница 42: ...42 KX TG1034B KX TG1035S KX TGA101B KX TGA101S 9 1 4 5 RF BBIC Interface Signal Wave Form SYCL SYEN SYDA ...
Страница 51: ...51 KX TG1034B KX TG1035S KX TGA101B KX TGA101S ...
Страница 52: ...52 KX TG1034B KX TG1035S KX TGA101B KX TGA101S 10 1 2 Handset ...
Страница 53: ...53 KX TG1034B KX TG1035S KX TGA101B KX TGA101S 10 1 3 Charger Unit ...
Страница 54: ...54 KX TG1034B KX TG1035S KX TGA101B KX TGA101S ...
Страница 55: ...55 KX TG1034B KX TG1035S KX TGA101B KX TGA101S 10 2 How to Replace the Handset LCD ...
Страница 67: ...67 KX TG1034B KX TG1035S KX TGA101B KX TGA101S Memo ...
Страница 71: ...71 KX TG1034B KX TG1035S KX TGA101B KX TGA101S Memo ...
Страница 78: ...78 KX TG1034B KX TG1035S KX TGA101B KX TGA101S Memo ...
Страница 89: ...89 KX TG1034B KX TG1035S KX TGA101B KX TGA101S 15 3 Cabinet and Electric Parts Charger Unit ...