2.9 Power Failure Connections
Installation Manual
59
2.9
Power Failure Connections
2.9.1
Power Failure Connections
When the power supply to the PBX fails, power failure transfer will switch from the current connection
to the Power Failure Connections.
Power Failure Connections connect a specific extension and an outside (CO) line in the event of
power failure as follows:
Outside (CO) line 1—extension (T, R) jack 01
Notes
•
In the event of a power failure, system memory is protected by a factory-provided lithium
battery. No system data will be lost, except for the Camp-on, Saved Number Redial, Last
Number Redial, and Call Park data.
•
The current connection automatically switches to the Power Failure Connection when the
power supply stops.
•
Proprietary telephones (PTs) cannot be used during a power failure. Therefore, we
recommend connecting a single line telephone (SLT) in parallel with a PT to extension jack
01.
•
As long as DC power is provided by the backup batteries, the PBX will remain fully
operational and the connection will not switch to the Power Failure Connections.