LED Indications
Indication
Colour
Description
CARD STATUS
Green/Red
Card status indication
•
OFF: Power Off
•
Green ON: Normal (all ports are idle)
•
Green Flashing (60 times per minute): Normal (a port is in use)
•
Red ON: Fault (includes reset)
•
Red Flashing (60 times per minute): Out of Service
SYNC-ERR
Red
Non-synchronisation status indication
•
OFF: Normal
•
ON: Out of synchronisation
RAI
Red
RAI signal status indication
•
OFF: Normal
•
ON: Alarm (Clock Slave)
•
Flashing (60 times per minute): Alarm (Clock Master)
AIS
Red
AIS status indication
•
OFF: Normal
•
ON: Alarm
SYNC
Green
Synchronisation status indication
•
OFF: Not synchronised
•
ON: Synchronised
•
Flashing (60 times per minute): Synchronised (Clock Master)
D-LINK
Green
Data link status indication
•
OFF: Not established
•
ON: Established
Maximum Cabling Distance of Extension Connection
The maximum length of the extension cable that connects the PRI30 cards is shown below:
Diameter Maximum
Distance
0.5 mm:
200 m
84
Installation Manual
2.4.10 PRI30 Card (KX-TDA0290CE/KX-TDA0290CJ)
Содержание KX-TDA150
Страница 23: ...Weight when fully mounted Under 12 kg Installation Manual 23 1 3 1 General Description ...
Страница 36: ...C Power Switch D Earth Terminal E AC Inlet 36 Installation Manual 2 2 2 Names and Locations ...
Страница 136: ...136 Installation Manual 2 11 1 Starting the PBX ...
Страница 153: ...Index Installation Manual 153 ...
Страница 157: ...Installation Manual 157 Notes ...