2.6 Connection of Extensions
Installation Manual
89
2.6.3
Digital EXtra Device Port (Digital XDP) Connection
A DPT can be connected to another DPT on the Digital XDP connection. In addition, a DPT connected to a
Super Hybrid Port can also have an SLT connected in Parallel mode or XDP mode.
Notes
•
Both DPTs must be KX-T7600 series DPTs (except KX-T7640). Note that the KX-T7667 can only
be connected as a slave DPT.
•
Parallel mode or XDP mode can be selected through system programming.
•
If XDP mode is enabled through system programming, parallel connection is not possible. Refer to
"1.10.9 Parallelled Telephone" and "2.1.1 Extension Port Configuration" in the Feature Guide for
further information.
With KX-T7600 Series DPT (except KX-T7600E Series)
Using a Modular T-Adaptor
To a Super Hybrid Port
4-conductor wiring cord
Connect pins "D1" and "D2".
Slave DPT
SLT
Master DPT
Modular
T-Adaptor
4-conductor wiring cord
Connect pins "D1" and
"D2".
2-conductor wiring cord
Connect pins "T" and "R".
Slave DPT
Master DPT
TO MAIN UNIT
/ PABX
TO TEL
TO MAIN UNIT
/ PABX
Cable
Maximum Distance
ø 0.4 mm:
30 m
ø 0.5 mm:
50 m
ø 0.6 mm:
60 m
CAT 5:
50 m
Back View of DPTs
To a Super Hybrid Port