background image

3.2 Data Reset After Upgrade

14

SD Memory Card Installation/Upgrade Guide

3.2

Data Reset After Upgrade

Data that is stored in the SRAM of the Hybrid IP-PBX (not on the SD Memory Card), among other 
data, is cleared during the upgrade process.
The data items listed below are all cleared by upgrade.

Outgoing Messages (OGMs)

Incoming Call Log

Outgoing Call Log (including Last Number Redial)

Message Waiting

SMDR

ICD Group monitor log for supervisor

PBX date and time

Timed Reminder

LPR Timed Update time

Daily test start time

PT handset/headset volume

PT SP-PHONE volume

PT  ring  volume

PT display contrast

ICD Group login status

(All extensions are set to Login by default.)

ICD Group Ready/Not Ready status

(All extensions are set to Ready by default.)

Live Call Screening (LCS) On/Off

Hands-free Answerback status

Absent Message status of extensions

(Absent Message data itself is not cleared.)

FWD/DND status

(FWD destinations are not cleared.)

Extension Lock/Remote Extension Lock

Extension PIN Lock/Extension PIN Lock counter

Verified Code PIN Lock/Verified Code PIN Lock counter

Password Lock counter for Remote System Programming

PBX Error Log

Содержание KX-TDA0920

Страница 1: ...d IP PBX 5 Upgrading a Hybrid IP PBX from a Previous Version of System Software KX TDA50 KX TDA100 KX TDA200 only 8 Restoring a Hybrid IP PBX to a Previous System Version KX TDA50 KX TDA100 KX TDA200 only 15 KX TDA5920 PSMPR Software File Version 3 0000 or later KX TDA0920 PMPR Software File Version 3 0000 or later KX TDA6920 PLMPR Software File Version 3 0000 or later Document Version 2006 02 ...

Страница 2: ...aintenance Console for the KX TDA600 At any point during a procedure you can use the SD Card File View and Load option from Maintenance Console s Utility menu to view the header information of files on the SD Memory Card This allows you to confirm that the correct versions of relevant files have been copied to the SD Memory Card The procedures described in this leaflet use the following files cont...

Страница 3: ... touching ground or wearing an earthing strap 1 1 1 KX TDA5920 KX TDA0920 KX TDA6920 Features The KX TDA5920 KX TDA0920 allow access to the following enhanced features For details on these features see the Feature Manual Enhanced CTI functions Network Direct Station Selection NDSS Automatic Call Distribution ACD Cellular Phone Features Call Transfer from Outside Destination DISA Automatic Walking ...

Страница 4: ...SD file stored on the SD Memory Card contains data necessary to use the new features If this file is damaged or accidentally deleted these new features will not function Using an SD Memory Card Reader back up all of the files and folders on the SD Memory Card including this file to a PC The contents of this file are different for every SD Memory Card so you must back up each SD Memory Card separat...

Страница 5: ...e the correct system data files using a connected PC 2 1 Procedure Before beginning the install procedure make sure that power is not supplied to the Hybrid IP PBX and the latest version of Maintenance Console is installed to the PC 1 Install the SD Memory Card in the SD Memory Card slot of the PBX KX TDA50 KX TDA100 KX TDA200 KX TDA600 SD CARD SD CARD SD CARD SD CARD SD CARD SD CARD ...

Страница 6: ...h back to the NORMAL position Initialization may take about 1 min to 3 min When initialization is complete the RUN indicator will stop flashing and turn on 5 Connect to the PBX using Maintenance Console Quick Setup will start automatically 6 Set the data items as prompted Quick Setup will finish Reset Button System Initialize Switch System Initialize Switch Reset Button SYSTEM INITIALIZE RESET NOR...

Страница 7: ...lity menu select File Transfer PBX SD Card to PC Note The screenshot shown here is for reference only and may differ from the display on your PC 2 Select DSKEYSD KX TDA50 DKEYSD KX TDA100 KX TDA200 or DLKEYSD KX TDA600 from the list of files 3 Click Transfer The Save dialog box will be displayed 4 Navigate to the folder in which you want to save the file 5 Enter a file name 6 Click Save A window s...

Страница 8: ...ared during the upgrade process including Outgoing Messages OGMs Before upgrading the PBX be sure to back up OGMs to a PC using Maintenance Console For a list of all items cleared during upgrade see 3 2 Data Reset After Upgrade The screenshots shown here are for reference only and may differ from the displays on your PC 1 Back up the current user data 1a Back up the current DSSYS DSYS system data ...

Страница 9: ...hen the transfer is complete 7 Click OK 8 From the File menu select eXit 9 Click OK The Maintenance Console software will close This step is necessary to switch to the current version of Maintenance Console 2 Upgrade the current user data 2a Convert the current DSSYS DSYS file for use with the new version 1 Start Maintenance Console Do not connect to the PBX The appropriate version of Maintenance ...

Страница 10: ...new version of Maintenance Console saved and opened 8 From the File menu select Close to close the currently open system file 3 Set up the new system version 3a Install the new SD Memory Card 1 Turn off the power to the PBX 2 Remove the current SD Memory Card from the SD Memory Card slot 3 Install the new SD Memory Card KX TDA50 KX TDA100 KX TDA200 SD CARD SD CARD SD CARD ...

Страница 11: ...ot been previously backed up to the PC using an SD Memory Card Reader it is strongly recommended to back up the DSKEYSD DKEYSD file after Quick Setup is complete Follow the procedure below a From the Utility menu select File Transfer PBX SD Card to PC b Select DSKEYSD KX TDA50 or DKEYSD KX TDA100 KX TDA200 from the list of files c Click Transfer The Save dialog box will be displayed d Navigate to ...

Страница 12: ...layed 2 Select the converted DSSYS DSYS file that was saved in Step 2 The file will be uploaded to the SD Memory Card as the backup DSSYS DSYS file KX TDA5920 DSSYS_S KX TDA0920 DSYS_SUB and a message displayed when the transfer is complete 3 Click OK 4b Set the transferred DSSYS DSYS file to be the active DSSYS DSYS file 1 From the Utility menu point to System Reset and then click Reset by the Co...

Страница 13: ... File for DSSYS DSYS and Keep Present File for PSMPR PMPR 4 Click OK A confirmation screen will be displayed 5 Click OK Another confirmation screen will be displayed 6 Click OK The active and backup DSSYS DSYS files will be swapped and the PBX reset The upgrade process is complete ...

Страница 14: ...Reminder LPR Timed Update time Daily test start time PT handset headset volume PT SP PHONE volume PT ring volume PT display contrast ICD Group login status All extensions are set to Login by default ICD Group Ready Not Ready status All extensions are set to Ready by default Live Call Screening LCS On Off Hands free Answerback status Absent Message status of extensions Absent Message data itself is...

Страница 15: ...turn to the previous version of system software and data Use this procedure if the upgrade process did not complete successfully 4 1 Procedure 1 Turn off the power to the PBX 2 Remove the new SD Memory Card that is currently installed in the PBX 3 Set the lock switch of the previous SD Memory Card for read only access 4 Install the previous SD Memory Card in the SD Memory Card slot of the PBX LOCK...

Страница 16: ...n Initialization may take about 1 min to 3 min When initialization is complete the RUN indicator will stop flashing and turn on 8 Turn off the power to the PBX again 9 Remove the SD Memory Card from the PBX and set the lock switch for read write access 10 Turn on the power to the PBX The previous version s DSSYS DSYS file will be copied from the SD Memory Card to the PBX Reset Button System Initia...

Страница 17: ...Procedure SD Memory Card Installation Upgrade Guide 17 The Hybrid IP PBX has been restored to the previous version Please note that the data listed in Section 3 2 Data Reset After Upgrade cannot be restored ...

Страница 18: ...65 de Infantería Km 9 5 Carolina Puerto Rico 00985 http www panasonic com csd Copyright This material is copyrighted by Panasonic Communications Co Ltd and may be reproduced for internal use only All other reproduction in whole or in part is prohibited without the written consent of Panasonic Communications Co Ltd 2006 Panasonic Communications Co Ltd All Rights Reserved PSQX3653ZA KK0206TK0 ...