2.2 Programming
36
Programming Guide
5.
Click
OK
.
You will see a confirmation screen.
Note
If your entry contains an invalid value, you will be prompted to correct your input. Enter
correct values for the parameters shown in red and try again.
6.
Confirm your entry and click
OK
.
To return to the previous screen, click
CANCEL
.
Parameter Descriptions
The parameters indicated with "
*
" must be changed while the VoIP Gateway Card is in the "STOP" status (see
"2.3.1 Status Control"). The changes do not have to be followed by a reboot to become effective.
DN2IP Entry
The parameters below are used to create DN2IP entries based on the gateway entries created previously (see
"2.2.6 Address Translation Table—GW Entry"). The DN2IP entries associate dialed numbers and IP address
of the destination; therefore, a caller can reach the destination by dialing the number without knowing the
destination IP address.
Note
If you are using a gatekeeper, create the DN2IP entries only for the local card. In this case, you can
create up to 4 DN2IP entries per card.
Note that if you are not using a gatekeeper, there is no maximum number of DN2IP entries.
Parameter & Description
Default
Value Range
*
Leading Number
Specifies the leading digits in dialed numbers by which to
associate calls with the appropriate destination.
For example, to associate calls with dialed numbers "950-
xxxx" and "951-xxxx" with separate destinations, it is
necessary to make 2 DN2IP entries with respective numbers,
"950" and "951".
No default
Max. 30 digits
*
Remaining Number of Digits
Specifies the number of digits to be dialed following the
leading number to access the destination.
For example, if the dialed numbers are either "950-xxxx" or
"951-xxxx" and the numbers "950" and "951" are specified for
the parameter
respectively, specify the
number "4" in this parameter.
0
0 to 29
*
GW No/Group No. Selection
Specifies the type of destination when making calls: a
gateway or a gateway group.
GW
GW,
Group
*
GW No/Group No.
Specifies the number of the destination gateway or gateway
group.
GW No: 0,
Group No.: 1
GW No: 0 to 511,
Group No.: 1 to 256
Содержание KX-TDA0484
Страница 6: ...1 1 Starting the IP GW4 Maintenance Utility 6 Programming Guide ...
Страница 52: ...2 5 Others 52 Programming Guide 2 5 2 Log Out 1 Click LOGOUT in the main menu 2 Click OK to log out ...
Страница 64: ...3 4 Others 64 Programming Guide 3 4 2 Log Out 1 Click LOGOUT in the main menu 2 Click OK to log out ...
Страница 65: ...Programming Guide 65 Index ...