Installation
62
Installation Manual
CAUTION
Be sure to turn the power switch "OFF" before you change the jumpers.
Note
a.
To use an ISDN extension line, an external or internal power supply is required. If you use
an internal power supply, set the power supply jumper cover to the "ON" position as below.
b.
To use the ISDN port as the CO line port, set the power supply jumper cover to the "OFF
position.
For CO line use
Jumper Cover
EXT
S0
1
3
1
3
1
3
1
3
For ISDN extension line use
EXT
S0
1
3
1
3
1
3
1
3
SW701
SW700
SW702
SW703
SW701
SW700
SW702
SW703
OR
b. View of Power supply jumper
OFF
ON
1
3
1
3
SW705
SW704
a. View of Power supply jumper
OFF
ON
1
3
1
3
SW705
SW704