* : Refer to
Adjustment (Base Unit)
()
16.2. Handset
Item
Value
Refer to -. **
Remarks
TX Power
More than 20 dBm ~ 25
dBm
Adjustment (Base Unit)
(I)
Modulation
340 kHz/div ~ 402 kHz/div
Adjustment (Base Unit)
(J)
Data type: Fig31
Frequency Offset
-50 kHz ~ +50 kHz
Adjustment (Base Unit)
(K)
RX Sensitivity
< 1000 ppm
Adjustment (Base Unit)
(L)
Timing Accuracy
< ± 10 ppm
Adjustment (Base Unit)
(M)
RSSI Level
0x34 hex ± A hex
Adjustment (Base Unit)
(N)
** : Refer to
Adjustment
()
17. HOW TO CHECK THE HANDSET SPEAKER
1. Prepare the digital voltmeter, and set the selector knob to ohm
meter.
2. Put the probes at the speaker terminals as shown below.
53
www.freeservicemanuals.info
1/2/2015
Digitized in Heiloo, Holland
Содержание KX-TCD420BXM
Страница 21: ...21 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 54: ...18 FREQUENCY TABLE MHz 54 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 82: ...82 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 84: ...33 ACCESSORIES AND PACKING MATERIALS 84 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 85: ...33 1 KX TCD420BXM BXS 33 2 KX A142EXM EXS 85 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 114: ...PbF R1 R2 TP4 TP1 TP2 TP3 Digital Volt Meter 12Ω 2W A www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...