Items
Adjustment
Point
Procedure*
Check
(M)
*
RSSI Level
Confirmation
-
Follow steps 1 to 3 of (H) above.
4. Set DECT tester power to -88dBm.
5. Execute the command "readrssi".
6. Confirm: 29 < returned value < 3E (hex)
IC2,IC3,L1,
C43,C78,C75,
C69,C48,C72,
C66,C67,C76,
C57,C73,L3,
DA1,R66,R67,
C55,C56,R78,
R79,C54,C58,