![Panasonic KX-TCD410AXM Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/panasonic/kx-tcd410axm/kx-tcd410axm_service-manual_3745387043.webp)
Items
Adjustment
Point
Procedure
Check
Replac
Parts
(O)
*
Transmit Audio
Check and
Adjustment
ANT
J1
1. Configure the DECT tester (CMD60) as follows;
<Setting>
-Test mode: FP
-Mode: Normal
-PMID: 0000
2. Execute the command "testmode".
3. Initiate connection from DECT tester.
4. Execute the command "hookoff".
5. Execute the command "openau".
6. Connect J1 (Telephone Socket) to Tel-simulator which is connected with 600 .
7. Set line voltage to 48V and line current to 40mA.
8. Input audio signal (30mVrms/1kHz tone) to DECT tester.
<DECT tester setting>
-Scramble: On
-AF Gen to ADPCM: On
-AF Meter Input: AF Voltm
-AF Gen Frequency: 1000Hz
-AF Gen Level: 30mVrms
9. Confirm hearing tone: 330mVrms ± 100mVrms.
10. Adjust audio level if required. (Make sure current value using "getspkrgain". And
then execute the command "setspkrgain xx", where xx is the value.)
11. Confirm that the audio distortion at 600R of Tel-simulator is < 5 %.
IC2, R3
C22,
R23, C8
C14,
C13, R2
R21,
Q6, R1
R19,
R20, C1
D2,
C1, C2
R77,
R16, D
R12,
Q2, R7,
R9, R1
Q3,
IC3, L
C43,
C78, C7
C69,
C48, C7
C66,
C67, C7
C57,
C73, L
DA1,
R66, R6
C55,
C56, R7
R79,
C54, C5
C86,
R38
(P
)
Charging Check
-
1. Connect Charge Contact 12 /2W register between and charge-.
2. Measure and confirm voltage across the regigster is 2.3V ± 0.2V.
D4, R4
R44
Note:
After the measuring, sock up the solder of TP.
* :
PC Setting
() is required beforehand.
The connection of adjustment equipment are as shown in
Adjustment Standard (Base Unit)
().
14.2. Adjustment Standard (Base Unit)
43
www.freeservicemanuals.info
11/8/2014
Digitized in Heiloo, Holland
Содержание KX-TCD410AXM
Страница 23: ... To exit the operation press any time 23 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 51: ...18 FREQUENCY TABLE MHz 51 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 58: ...25 CPU DATA BASE UNIT 25 1 IC2 BBIC 58 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 74: ...74 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 76: ...76 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 82: ...82 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Страница 104: ...PbF R1 R2 TP4 TP1 TP2 TP3 Digital Volt Meter 12Ω 2W A www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...