8.4. Check Point (Charger Unit)
Items
Adjustment
Point
Procedure
Check or
Replace Parts
(A)
Charging Check
-
1.
Connect Charge Contact 12
Ω
/2W resistor between and charge-.
2.
Measure and confirm voltage across the resistor is 2.7V ± 0.2V.
D1,R1,R2
Note:
After the measuring, sock up the solder of TP.
The connection of adjustment equipment are as shown in Adjustment Standard (Charger Unit) (P.30).
8.5. Adjustment Standard (Charger Unit)
When connecting the Simulator Equipments for checking, please refer to below.
8.5.1. Flow Solder Side View
PbF
R1
R2
TP4
B
TP1
TP2
TP3
Digital Volt Meter
12
Ω
/2W
(A)
PQUP11205Z
Note:
(A) is referred to Check Point (Charger Unit) (P.30)
30
KX-TCD150FXB / KX-TCD150FXC / KX-TCD152FXB / KX-TCA115EXB / KX-TCA115EXC
Содержание KX-TCD150FXB
Страница 10: ...4 5 For Service Hint 10 KX TCD150FXB KX TCD150FXC KX TCD152FXB KX TCA115EXB KX TCA115EXC ...
Страница 15: ...6 2 How to Replace the Handset LCD 15 KX TCD150FXB KX TCD150FXC KX TCD152FXB KX TCA115EXB KX TCA115EXC ...
Страница 46: ...19 SIGNAL ROUTE 46 KX TCD150FXB KX TCD150FXC KX TCD152FXB KX TCA115EXB KX TCA115EXC ...
Страница 50: ...22 ENGINEERING MODE 22 1 Base Unit 50 KX TCD150FXB KX TCD150FXC KX TCD152FXB KX TCA115EXB KX TCA115EXC ...
Страница 52: ...22 2 Handset 52 KX TCD150FXB KX TCD150FXC KX TCD152FXB KX TCA115EXB KX TCA115EXC ...
Страница 56: ...24 CABINET AND ELECTRICAL PARTS BASE UNIT 56 KX TCD150FXB KX TCD150FXC KX TCD152FXB KX TCA115EXB KX TCA115EXC ...
Страница 60: ...27 2 KX TCD152FXB 60 KX TCD150FXB KX TCD150FXC KX TCD152FXB KX TCA115EXB KX TCA115EXC ...
Страница 66: ...Memo 66 KX TCD150FXB KX TCD150FXC KX TCD152FXB KX TCA115EXB KX TCA115EXC ...