15.2. Power Supply Circuit
The power is supplied to the DECT BBIC, RF Module, EEPROM and Charge Contact from AC Adaptor (+6V) as shown in
Fig.101. The power supply is as follows;
•
•
•
•
DECT BBIC (IC8):
CN1 (+6V)
→
D1
→
IC1
→
Q2
→
IC8
CN1 (+6V)
→
D1
→
IC1
→
Q3
→
IC8
•
•
•
•
RF Module (IC2):
CN1 (+6V)
→
D1
→
IC1
→
Q2
→
IC2 (PLL)
CN1 (+6V)
→
D1
→
IC1
→
Q6
→
IC2 (Power AMP)
•
•
•
•
EEPROM (IC3):
CN1 (+6V)
→
D1
→
IC1
→
Q2
→
IC3
•
•
•
•
Charge Contact (TP16):
CN1 (+6V)
→
D1
→
R4, R5
→
TP16
<Fig.101>
47
KX-TCD815RUS / KX-TCD815R UT / KX-TCA181RUS / KX-TCA181RUT
Содержание KX-TCA181RUT
Страница 11: ...4 5 For Service Hint 11 KX TCD815RUS KX TCD815RUT KX TCA181RUS KX TCA181RUT ...
Страница 21: ...Cross Reference Check Point Base Unit P 26 21 KX TCD815RUS KX TCD815RUT KX TCA181RUS KX TCA181RUT ...
Страница 23: ...Cross Reference Check Point Handset P 35 23 KX TCD815RUS KX TCD815RUT KX TCA181RUS KX TCA181RUT ...
Страница 53: ...19 SIGNAL ROUTE 53 KX TCD815RUS KX TCD815RUT KX TCA181RUS KX TCA181RUT ...
Страница 59: ...22 ENGINEERING MODE 22 1 Base Unit 59 KX TCD815RUS KX TCD815RUT KX TCA181RUS KX TCA181RUT ...
Страница 62: ...22 2 Handset 62 KX TCD815RUS KX TCD815RUT KX TCA181RUS KX TCA181RUT ...
Страница 74: ...26 CABINET AND ELECTRICAL PARTS BASE UNIT 74 KX TCD815RUS KX TCD815RUT KX TCA181RUS KX TCA181RUT ...
Страница 76: ...28 CABINET AND ELECTRICAL PARTS CHARGER UNIT 76 KX TCD815RUS KX TCD815RUT KX TCA181RUS KX TCA181RUT ...
Страница 78: ...29 2 KX TCA181RUS RUT 78 KX TCD815RUS KX TCD815RUT KX TCA181RUS KX TCA181RUT ...
Страница 80: ...30 3 Charger Unit 80 KX TCD815RUS KX TCD815RUT KX TCA181RUS KX TCA181RUT ...
Страница 94: ...Memo 94 KX TCD815RUS KX TCD815RUT KX TCA181RUS KX TCA181RUT ...