background image

Feature Guide References

None

Extension Name

Specifies the name of the PS.

Value Range

Max. 20 characters

Maintenance Console Location

6.10  [4-2-1] Portable Station—Extension Settings

Programming Manual References

3.61  [1-2] Portable Station—

Extension Name

Feature Guide References

None

Group CW w/o Tone (Ring after Call)

Enables an incoming call to an incoming call distribution group to arrive at a previously busy extension at the
moment that the extension goes on-hook for the previous call.

Value Range

Disable, Enable

Maintenance Console Location

6.10  [4-2-1] Portable Station—Extension Settings

Programming Manual References

None

Feature Guide References

None

Wrap-up Timer

Specifies the length of time that must pass after completing a call before a PS will accept another call when
logged in as a member of an Incoming Call Distribution Group.
This timer is used when "

Options—Wrap-up Timer based on

" is set to "

Extension

" in 

5.16  [3-5-3]

Incoming Call Distribution Group—Miscellaneous

.

Value Range

0–3000 s

764

PC Programming Manual

6.10 [4-2-1] Portable Station—Extension Settings

Содержание KX-NCP500

Страница 1: ...fully before using this product and save this manual for future use KX NCP500 KX NCP1000 PBMPR Software File Version 4 1000 or later KX TDE100 KX TDE200 PMMPR Software File Version 4 1000 or later KX...

Страница 2: ...elated sections of the PC Programming Manual are listed for your reference Feature Guide References The Feature Guide explains what the PBX can do as well as how to obtain the most of its many feature...

Страница 3: ...or enter the power saving system standby mode while the Maintenance Console is connected to the PBX To perform either of the operations above first close the connection to the PBX Trademarks Microsof...

Страница 4: ...ed Services Digital Network ISDN using ISDN primary rate access ONP 2048 kbit s digital structured leased lines D2048S The KX TDE600UK KX TDE600NE and KX TDE600GR are designed to interwork with the An...

Страница 5: ...auncher Connect Profile Setup 44 2 3 File 45 2 3 1 File Close 45 2 3 2 File Save 46 2 3 3 File Save As 47 2 3 4 File Exit 48 2 4 Disconnect 49 2 4 1 Disconnect Disconnect 49 2 5 Tool 50 2 5 1 Tool SD...

Страница 6: ...Virtual IP Gateway GK Settings 175 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings 176 3 12 1 1 Slot Shelf Property Virtual IP Gateway DN2IP 183 3 13 1 1 Slot Shelf Property Virtual IP Gat...

Страница 7: ...54 1 1 Slot Port Property IP GW Port Connection Command KX TDE series only 431 3 55 1 1 Slot Card Property IP Extension KX TDE series only 432 3 56 1 1 Slot Card Property IP Extension Common Settings...

Страница 8: ...23 3 8 2 VM DTMF Group Group Settings 664 5 24 3 8 2 VM DTMF Group Group Settings Member List 666 5 25 3 9 PS Ring Group 667 5 26 3 9 PS Ring Group Member List 669 5 27 3 10 Conference Group 670 5 28...

Страница 9: ...lan Time Time Setting 872 10 5 8 4 Routing Plan Priority 873 10 6 8 5 Carrier 874 10 7 8 6 Leading Number Exception 877 10 8 8 7 Authorisation Code for TRG 878 11 9 Private Network 879 11 1 9 1 TIE Ta...

Страница 10: ...re File Version 2 0xxx 966 14 1 4 KX TDE100 KX TDE200 PMMPR Software File Version 2 01xx 967 14 1 5 KX TDE100 KX TDE200 PMMPR Software File Version 3 0xxx 968 14 1 6 KX TDE100 KX TDE200 PMMPR Software...

Страница 11: ...Section 1 Overview This section provides an overview of programming the PBX PC Programming Manual 11...

Страница 12: ...enter programming mode will be denied access Ways to Programme There are two programming methods PC Personal Computer Programming All features and settings of the PBX can be programmed through PC pro...

Страница 13: ...on a white background below can be used when storing a name message password or other text entry data using a PC The available characters vary according to the model of PBX Table 1 Standard PC Program...

Страница 14: ...Table 2 For CE model 14 PC Programming Manual 1 1 2 Entering Characters...

Страница 15: ...Table 3 For RU model PC Programming Manual 15 1 1 2 Entering Characters...

Страница 16: ...Table 4 For GR model 16 PC Programming Manual 1 1 2 Entering Characters...

Страница 17: ...or Windows 7 Professional you must be logged in as a user in the Administrators group 1 Copy the setup file of the Maintenance Console to your PC 2 Double click the setup file to run the installer 3...

Страница 18: ...area data of the PBX Replacement may take several minutes to complete b Follow the procedure described in 3 13 1 Starting the PBX for KX NCP500 KX NCP1000 3 13 1 Starting the PBX for KX TDE100 KX TDE...

Страница 19: ...e properly if these IP addresses are changed A DHCP server must be able to use a client identifier option specified by RFC 2131 The PBX will not start properly if the IP addresses cannot be assigned a...

Страница 20: ...e installation of the Maintenance Console It can also be enabled in Options Note When starting the Maintenance Console if there is less than 80 MB of available memory this feature is automatically dis...

Страница 21: ...be automatically displayed for easy access to your PBX 3 Click Connect PBX Web Manager Main Menu After successful login the main menu will appear where settings can be changed Note While logged in if...

Страница 22: ...mer code to access installer level PC programming All system programming settings are available The three programmer codes used for PC programming can be set through Maintenance Console For more infor...

Страница 23: ...Section 2 Introduction of Maintenance Console This section serves as reference operating instructions when using the Maintenance Console software to programme the PBX PC Programming Manual 23...

Страница 24: ...mer code 2 Click OK The programme launcher will appear 3 Click Connect Connection options will be displayed Select a Profile Name if you want to use a pre saved profile This option is only available w...

Страница 25: ...on Modem Initialise Enter the modem initialise command and click Initialise to send the command to the modem For more details refer to your modem s instruction manual Connection Settings for LAN Setti...

Страница 26: ...N Remote Setting Values Explanation Dial Number 30 digits consisting of 1 9 0 and comma Enter the telephone number to be dialled to access the PBX 26 PC Programming Manual 2 1 1 Starting Maintenance C...

Страница 27: ...levels this is noted in this manual in the initial description of that menu option for example This option is only available at Installer level If a sentence like this does not appear under the headi...

Страница 28: ...All OUS Simplified Voice Message Delete All Recording Simplified Voice Message Check Current Usage Call Pickup for My Group Extension List View Import Feature Speed Dial and Caller ID Import Incoming...

Страница 29: ...ansion Export SIP Extension Export V IPGW16 GW Settings Export V IPGW16 DN2IP Screen Customize User Level Screen Customize Administrator Level Utility Menu Option Batch Interactive U A I U A I Diagnos...

Страница 30: ...er FTP to IP Equipment NT400 File Transfer FTP to IP Equipment NT3xx Card Software Timed Update System Reset Reset by the Command View Menu Option Batch Interactive U A I U A I Toolbar Statusbar Syste...

Страница 31: ...ed into several areas as shown below 1 2 3 4 5 6 1 Menu Bar Provides access to file management and connection options as well as tools and utilities used in programming the PBX For details see Section...

Страница 32: ...xpanded sub topic will hide the names of individual screens Double click on a screen name to open that screen in 6 Main Screen below This menu can be positioned freely Click and drag the title bar of...

Страница 33: ...standard buttons that are displayed on many screens within the Maintenance Console The standard buttons are as follows Button Function OK Implements changes and closes the current screen Cancel Aband...

Страница 34: ...s that the card is installed correctly in the PBX and is capable of being used normally Out of service means that the card is installed correctly in the PBX but has been temporarily removed from use T...

Страница 35: ...he bottom of the Maintenance Console window System Menu Displays or hides the menu of PBX setting screens Window Cascade When multiple data screens are open displays all open screens overlapped with t...

Страница 36: ...ge Wired Extension Portable Station VM Group DPT VM Group DTMF ICD Group PS Ring Group OGM DISA External Pager Analogue MODEM ISDN Remote Extension Numbers Names List Displays all available extensions...

Страница 37: ...created here to the SD memory card installed in the PBX see 2 6 2 Utility File Transfer PC to PBX SD Card Note Since selecting this option creates a blank system data file uploading this file to the...

Страница 38: ...that were created by the Maintenance Console for a supported PBX To upload a file opened here to the SD memory card installed in the PBX see 2 6 2 Utility File Transfer PC to PBX SD Card To open a sy...

Страница 39: ...file This option is only available when one or more profiles have been previously stored a Select the profile to use from the drop down list b If the system password for the PBX has not been stored wi...

Страница 40: ...a Profile Name if you want to use a pre saved profile a Select the profile to use from the drop down list b If the system password for the PBX has not been stored with the profile enter it If the syst...

Страница 41: ...red with the selected profile it does not need to be entered To enter the parameters manually select the PBX Model and confirm that the LAN radio button is selected a Specify the settings as required...

Страница 42: ...assword has been stored with the selected profile it does not need to be entered To enter the parameters manually select the PBX Model and confirm that the Modem radio button is selected a Specify the...

Страница 43: ...SDN Remote 1 From the programme launcher select Connect The Login window will be displayed 2 Select a connection option Select a Profile Name if you want to use a pre saved profile a Select the profil...

Страница 44: ...kup of all profiles This allows you to use the original connection settings with the new Maintenance Console The functions of the buttons on this screen are as follows Button Function Profile File Ope...

Страница 45: ...the programme launcher To close a system data file From the File menu select Close If the system data file has not been saved a warning message will be displayed giving you the option to save the file...

Страница 46: ...pload a file saved here to the SD memory card installed in the PBX see 2 6 2 Utility File Transfer PC to PBX SD Card To save a system data file From the File menu select Save If the data has never bee...

Страница 47: ...fer PC to PBX SD Card To save a system data file with a new name 1 From the File menu select Save As 2 Navigate to the folder in which you want to save the file 3 Enter a file name or select a file to...

Страница 48: ...Console From the File menu select Exit If the system data file being modified has not been saved a warning message will be displayed giving you the option to save the file Click Yes to save the file C...

Страница 49: ...e PBX When this option is chosen system data is automatically backed up from the PBX to the SD memory card see 2 5 1 Tool SD memory backup To disconnect 1 From the Disconnect menu select Disconnect A...

Страница 50: ...y backup Saves system data from the PBX to the SD memory card Backup begins as soon as this option is chosen To back up system data From the Tool menu select SD memory backup 50 PC Programming Manual...

Страница 51: ...us At any time on this screen you can click Close to return to the previous screen without saving To configure the BRI card 1 From the Tool menu select BRI Automatic Configuration 2 Select the BRI car...

Страница 52: ...s it at the connected PBX To clear this data at other PBXs in the network it is necessary to run this tool at those PBXs To clear the NDSS Link Data From the Tool menu select NDSS Link Data Clear A co...

Страница 53: ...P All OUS Sets the status of all DXDP XDP extension ports to OUS simultaneously To set all DXDP XDP ports to OUS 1 From the Tool menu select DXDP All OUS 2 Click OK PC Programming Manual 53 2 5 4 Tool...

Страница 54: ...s recorded by the SVM feature To delete voice messages 1 From the Tool menu point to Simplified Voice Message and select Delete All Recording 2 Select the card from which to delete messages 3 Click OK...

Страница 55: ...stored by the SVM feature For each message the type of message and the associated extension are displayed To view SVM message status From the Tool menu point to Simplified Voice Message and select Ch...

Страница 56: ...Group The Group Call Pickup feature number default 40 the extension user group number of the extension is assigned to first personal speed dial Note This tool can only be activated if all of the follo...

Страница 57: ...ype Detail Intercom Wired Extension VM Voice Mail Portable Station Wireless Extension Portable Station ICDG Incoming Call Distribution Group WG PS Ring Group VM DPT VM DPT Group VM DTMF VM DTMF Group...

Страница 58: ...al and Caller ID Data Type Import Destination System Speed Dialling Number Location Name Name CO Line Access Number Telephone Number Dial CLI Destination CLI Destination Related programming 8 1 6 1 Sy...

Страница 59: ...Related programming 10 3 8 3 Routing Plan Time Wired Extension Data Type Import Destination No Location selected automatically Extension Number Extension Number selected automatically Extension Name...

Страница 60: ...word Related programming 3 18 1 1 Slot Port Property Virtual SIP Extension Port V IPGW16 GW Settings Data Type Import Destination No Location GW Name GW Name GW IP Address GW IP Address GW Group GW Gr...

Страница 61: ...5 For the Feature Speed Dial and Caller ID table select the Speed Dial table to which to import the data system or tenant from the drop down list 6 If required select import fields When import fields...

Страница 62: ...anel To export system data 1 From the Tool menu point to Export and then click the type of data to export 2 Navigate to the folder in which you want to save the file 3 Enter a file name 4 Click Save W...

Страница 63: ...e Console and in the menu bar to users with the level of access being edited To modify displayed screens 1 From the Tool menu point to Screen Customize and then click the access level to modify 2 Sele...

Страница 64: ...6 ESLC16 EMSLC16 CSLC16 ECSLC24 CSIF LCOT ELCOT T1 E1 BRI PRI OPB E M DID IP EXT Card CT Bus diagnosis KX NCP500 KX NCP1000 KX TDE100 KX TDE200 only DHLC DLC SLC8 SLC16 MSLC16 CSLC16 CSIF LCOT T1 E1 B...

Страница 65: ...d for the pair port tests must be installed within the same shelf The tests that are performed are as follows Line current OFF Ext CO Line current from extension to trunk turns off Line current ON Ext...

Страница 66: ...The version of the PRI23 card must be 2 000 or later To perform a network loopback test 1 From the Utility menu select Diagnosis 2 Click on the Status cell of the PRI23 card and set it to OUS 3 Click...

Страница 67: ...d LIC files Use the Activation Key button see 3 3 1 1 Slot Activation Key for other LIC files and the SD Card File View and Load utility see 2 6 4 Utility SD Card File View and Load for all other file...

Страница 68: ...EMSLC16 PEESLC ECSLC24 PELCOT ELCOT PEECHO EECHO PBUSS BUS S CS Programme Name on SD Memory Card Corresponding Unit PCSDECT CS using a CSIF card for DECT Portable Station PDCSDECT CS using a DHLC DLC...

Страница 69: ...SD Memory Card Corresponding Card DGSYS IPCEMPR DGSYS_S IPCEMPR 1 1 DGSYS file format data that is transferred to the PBX from the PC is saved as DGSYS_S Language Data Name on SD Memory Card Correspon...

Страница 70: ...PGW16 DBIVIPEX V IPEXT32 DBIVSPEX V SIPEXT32 KX TDE100 KX TDE200 Name on SD Memory Card Corresponding Card DMINI IPCMPR DMIDHLC DHLC8 DMISLC SLC8 CSLC16 DMIDLC DLC8 DLC16 DMIBRI BRI DMICSINF CSIF DMIL...

Страница 71: ...NI IPCEMPR DGIDHLC DHLC8 DGISLC SLC8 EMSLC16 ESLC16 CSLC16 ECSLC24 DGIDLC DLC8 DLC16 DGIBRI BRI DGICSINF CSIF DGILCOT ELCOT16 DGIT1 T1 DGIE1 E1 DGIEM E M DGIOPB3 OPB3 DGIEIO EIO DGIIPGW2 IP GW4 DGIIPG...

Страница 72: ...Select the file to upload A window showing the upload progress will be displayed While transferring files to the SD memory card the PBX automatically renames them according to the header information...

Страница 73: ...analysed by your dealer to identify the source of a problem If there is only one error data file its name will be SYSERR If there is more than one file the files will be numbered in chronological orde...

Страница 74: ...the Utility menu select SD Card File View and Load 2 Click on the name of the desired file Only files containing programme data whose filenames start with P can be selected 3 Click Detail The Detail...

Страница 75: ...lity KX NCP500 KX NCP1000 PBMPR DBSYS KX TDE100 KX TDE200 PMMPR DMSYS KX TDE600 PGMPR DGSYS To delete files from the SD memory card 1 From the Utility menu select SD Card File Delete 2 Click on the fi...

Страница 76: ...he file s header information Uploaded files are automatically renamed as necessary If this location already contains an OGM it will be overwritten by the newly uploaded message To transfer OGMs to an...

Страница 77: ...Message File Transfer PBX to PC 2 From the upper drop down list select the target MSG ESVM card block 3 From the lower drop down list select the messages to transfer To transfer a certain message sele...

Страница 78: ...ext file Minor Displays minor errors which affect only a certain part of system operation Major Displays major errors which affect operation of the whole system or result in system failure Clear Erase...

Страница 79: ...lt in ESVM card 01 to 11 Free Slots KX TDE600 Physical slot Basic Shelf 00 to 10 00 IPCEMPR Card Slot Built in ESVM card 01 to 10 Free Slots Expansion Shelf 01 to 12 01 to 11 Free Slots 12 BUS S Card...

Страница 80: ...To view the error log From the Utility menu select Error Log 80 PC Programming Manual 2 6 8 Utility Error Log...

Страница 81: ...versa will be highlighted in red until the next screen refresh is performed To view signalling bit information 1 From the Utility menu select T1 E1 Signalling Bit Monitor 2 From the Slot No drop down...

Страница 82: ...lity menu select T1 E1 Line Trace 2 From the Slot No drop down list select the target slot 3 From the CH No drop down list select the target channel 4 Click Start Trace information will be displayed T...

Страница 83: ...ton is clicked Accumulation Trace Previously accumulated data is retrieved and displayed Error Accumulation Trace Previously accumulated error data is retrieved and displayed This trace shows the data...

Страница 84: ...16 Protocol Trace When the progress bar disappears the protocol trace is complete The trace data has been saved to the SD Memory Card file name PRTH323 To transfer trace data to the PC 1 From the Util...

Страница 85: ...s of Signal RAI 301 Digital trunk RAI signal reception AIS 302 Digital trunk Alarm Indication Signal reception Frame Failure 300 Digital trunk frame failure Loss of Frame Counter of minor communicatio...

Страница 86: ...to arrive To view IP extension information 1 From the Utility menu select IP Extension Statistical Information 2 From the Card Selection drop down list select the slot number for the card IPCMPR VoIP...

Страница 87: ...the display shows OFF The number of paths that can be used varies for each CS model For more details see the documentation for your CS Group Call Number of PSs registered to the attached CS that are m...

Страница 88: ...llows Item Description PS No PS location number Only registered PSs will be displayed Extension Number Extension number of the PS Location Slot Slot number of the CS that the PS is registered with Loc...

Страница 89: ...ed with CS ID 12 digit ID number of the CS that each CS is currently synchronised with Monitored Value Monitored value dBm of the CS that each CS is currently synchronised with Monitored Level Monitor...

Страница 90: ...vailable when the Maintenance Console is in Interactive mode To perform a Ping test 1 Enter a specific IP address in the IP Address box 2 Click Test to perform the test The result will be displayed 3...

Страница 91: ...lity menu select File Transfer FTP to IP Equipment and then either IP CS or NT400 2 Input the FTP Server Address and File Name 3 Put a check in the Select check boxes of the items to be updated 4 Clic...

Страница 92: ...FTP Server Address and File Name 3 Click Execute Note This utility is not available when the PBX is connected to the Maintenance Console via a LAN connection Ports cannot be selected All registered p...

Страница 93: ...e list of these commands is as follows Card status change INS OUS Diagnosis commands Card installation Card deletion Remote reset LPR programme download requests ISDN automatic setup requests BRI card...

Страница 94: ...e to run the IPCMPR board of the PBX PMMPR_S Backup PBX programme file KX TDE600 File Name Description DGSYS Main system data file Contains all of the current configuration data for the PBX DGSYS_S Ba...

Страница 95: ...the corresponding options are not available 4 Click OK A confirmation screen will be displayed 5 Select an option Click OK to reset the PBX If OK is clicked a final confirmation screen will be display...

Страница 96: ...ied Is the baud rate correct The default setting and a safe rate is 19 200 bps Is the password correct Is the Maintenance Console not connected to the PBX by another connection method Q The Maintenanc...

Страница 97: ...fer PC to PBX SD Card Maintenance Console Software Q How do I confirm the software version of the PBX or installed cards A From 3 1 1 1 Slot click Summary Summary information including software versio...

Страница 98: ...ation within transmission range of the CS Has the Portable Station previously been registered at another location It is not possible to register a Portable Station at 2 locations so use the Forced De...

Страница 99: ...s and then back to INS status Q How do I change the extension numbering plan from 3 digit numbers to 4 digit numbers A Perform the following steps 1 Open the 4 9 2 6 1 Numbering Plan Main screen 2 Ent...

Страница 100: ...ibly overlap with another Leading Number So for example if 2 is already set as a Leading Number it is not possible to set 21 as another Leading Number because of the possible overlap of extension numb...

Страница 101: ...An extension A Dial setting see 11 1 9 1 TIE Table Quick Dialling see 4 10 2 6 2 Numbering Plan Quick Dial In any of these cases choose another number Q I cannot change a feature number on the B NA DN...

Страница 102: ...PBX s battery backup memory Incoming Call Log Outgoing Call Log including Last Number Redial Message Waiting SMDR Advice of Charge AOC Pay Tone Hospitality guest billing data ICD Group monitor log fo...

Страница 103: ...rt Type of the port you want to use to either QSIG Slave or QSIG Master Q How do I change the type of an extension port A Set the port to OUS status Then change DPT Type Type in the 3 24 1 1 Slot Port...

Страница 104: ...extensions associated with a COS from making trunk calls set all trunk groups for that COS to Block blue Q How do I modify the hold operation for SLTs A It is possible to choose how to hold a line and...

Страница 105: ...to add in a blank cell of the Extension Number column 3 Set Delayed Ring as necessary 4 Click Apply Note that it is necessary to set the extension number of the ICD group in advance Q I cannot set sys...

Страница 106: ...106 PC Programming Manual 2 7 1 Frequently Asked Questions FAQ...

Страница 107: ...Section 3 1 Configuration PC Programming Manual 107...

Страница 108: ...image for virtual slots Select Shelf will be shown under the mouse pointer 2 Click Select Shelf To install a new shelf to the PBX KX TDE600 only 1 Move the mouse pointer over the first greyed PBX imag...

Страница 109: ...ard Setup screen will be displayed See 3 60 1 1 Slot OPB3 Option Card Setup To access IP PT port properties 1 Click the IP Phone Registration button Supported Card Types KX NCP500 KX NCP1000 Card Maxi...

Страница 110: ...NCP500 4 KX NCP1000 4 3 17 1 1 Slot Card Property Virtual SIP Extension V IPGW16 Virtual 16 Channel VoIP Gateway Card KX NCP500 2 KX NCP1000 2 3 9 1 1 Slot Shelf Property Virtual IP Gateway V IPCS4 V...

Страница 111: ...COT4 4 Port Analogue Trunk Card KX TDE100 6 KX TDE200 8 3 29 1 1 Slot Card Property LCO type LCOT8 8 Port Analogue Trunk Card LCOT16 16 Port Analogue Trunk Card DID8 8 Port DID Card KX TDE100 6 KX TDE...

Страница 112: ...TDE100 KX TDE200 Installation Manual 1 2 1 Optional Equipment 3 3 1 IPCMPR Card 3 4 1 Virtual Cards KX TDE600 Card Maximum Quantity Card Programming IPCEMPR IP Convergence Main Processing Card 1 fixed...

Страница 113: ...ard 40 3 52 1 1 Slot Card Property IP Gateway KX TDE series only IP GW16 16 Channel VoIP Gateway Card OPB3 Optional 3 Slot Base Card 16 3 58 1 1 Slot OPB3 Card Property EECHO16 16 Channel Echo Cancell...

Страница 114: ...entheses after the name Value Range Card Type for KX NCP500 KX NCP1000 DHLC4 4 Port Digital Hybrid Extension Card DLC8 8 Port Digital Extension Card DLC16 16 Port Digital Extension Card SLC8 8 Port Si...

Страница 115: ...ingle Line Telephone Extension with Message Lamp Card SLC8 8 Port Single Line Telephone Extension Card ESLC16 16 Port Single Line Telephone Extension Card CSLC16 16 Port Single Line Telephone Extensio...

Страница 116: ...s always displayed as Value Range INS The port is in service OUS The port is out of service Fault The port is not communicating with the network Pre Install A card has been added to the slot Idle No c...

Страница 117: ...ation 3 2 1 1 Slot Summary Programming Manual References 3 1 1 1 Slot Feature Guide References None Slot Type Indicates the slot type reference only Value Range Trunk Extension Maintenance Console Loc...

Страница 118: ...1 Slot Card Property Virtual SIP Extension 3 9 1 1 Slot Shelf Property Virtual IP Gateway 3 20 1 1 Slot Card Property Virtual IPCS Feature Guide References None Status Indicates the card status refere...

Страница 119: ...hones can be used IPCMPR ID for KX NCP500 KX NCP1000 KX TDE100 KX TDE200 IPCEMPR ID for KX TDE600 Indicates the ID number of the MPR card reference only Value Range ID number of the MPR card Maintenan...

Страница 120: ...ne ch 32 Maintenance Console Location 3 3 1 1 Slot Activation Key Programming Manual References None Feature Guide References None The number of activated feature by Activation Key File in SD Card Ind...

Страница 121: ...provided by the DSP card and activation key files on the SD memory card reference only Value Range Not applicable Maintenance Console Location 3 3 1 1 Slot Activation Key Programming Manual Reference...

Страница 122: ...l References None Feature Guide References 2 4 5 Dynamic Host Configuration Protocol DHCP Assignment MAC Address for IPCMPR Card for KX NCP500 KX NCP1000 KX TDE100 KX TDE200 MAC Address for IPCEMPR Ca...

Страница 123: ...References None MAC Address for VoIP DSP Indicates the MAC address of the DSP card reference only Value Range 00 00 00 00 00 00 FF FF FF FF FF FF Maintenance Console Location 3 4 1 1 Slot Card Proper...

Страница 124: ...Slot Card Property IPCMPR for KX NCP500 KX NCP1000 KX TDE100 KX TDE200 IPCEMPR for KX TDE600 Programming Manual References None Feature Guide References None Default Gateway Specifies the IP address o...

Страница 125: ...eferences None Feature Guide References None Speed Duplex for Maintenance Port Specifies the connection mode of the maintenance port The connection is made in 100Mbps half duplex when Auto Negotiation...

Страница 126: ...1 65535 Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR for KX NCP500 KX NCP1000 KX TDE100 KX TDE200 IPCEMPR for KX TDE600 Programming Manual References None Feature Guide References 2...

Страница 127: ...r KX NCP500 KX NCP1000 KX TDE100 KX TDE200 IPCEMPR for KX TDE600 Programming Manual References None Feature Guide References None DSP Card Status Indicates whether the DSP card is enabled for use refe...

Страница 128: ...unt of BGM Specifies how many IP PTs connected to the MPR card can send out BGM Value Range When using the built in ESVM card 0 113 When not using the built in ESVM card 0 117 Maintenance Console Loca...

Страница 129: ...for KX NCP500 KX NCP1000 KX TDE100 KX TDE200 IPCEMPR for KX TDE600 Programming Manual References None Feature Guide References None Jitter Compensation Operation for G 711 FAX Enables the use of a ji...

Страница 130: ...r for voice communications Value Range 0 200 ms Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR for KX NCP500 KX NCP1000 KX TDE100 KX TDE200 IPCEMPR for KX TDE600 Programming Manual Ref...

Страница 131: ...one Jitter Buffer Adaptation Period for Voice Specifies the length of time that the jitter buffer is applied for voice communications Value Range 1000 65530 ms Maintenance Console Location 3 4 1 1 Slo...

Страница 132: ...Slot Card Property IPCMPR for KX NCP500 KX NCP1000 KX TDE100 KX TDE200 IPCEMPR for KX TDE600 Programming Manual References None Feature Guide References None Jitter Buffer Delay Init for FAX Specifie...

Страница 133: ...References None DTMF Detection Level for G 711A Specifies the level of DTMF detection for the G 711A codec Value Range 45 12 dB Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR for KX N...

Страница 134: ...CP500 KX NCP1000 KX TDE100 KX TDE200 IPCEMPR for KX TDE600 Programming Manual References None Feature Guide References None CNG Signal Effective Detection Width 2 OFF Specifies the length of time that...

Страница 135: ...equired for the CED called station identification signal to be detected by the PBX Value Range 50 n n 1 100 ms Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR for KX NCP500 KX NCP1000 K...

Страница 136: ...PR for KX NCP500 KX NCP1000 KX TDE100 KX TDE200 IPCEMPR for KX TDE600 Programming Manual References None Feature Guide References None DSP CODEC G 711 only SIP extension Specifies whether or not to on...

Страница 137: ...e priority 1 codec set for the following types of calls IP extension calls SIP trunk calls Value Range Enable Disable Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR for KX NCP500 KX NC...

Страница 138: ...E200 IPCEMPR for KX TDE600 Programming Manual References None Feature Guide References None CTI Port Number Specifies the port number used to operate CTI via the LAN Selecting 0 disables the 3rd Party...

Страница 139: ...Assistant Feature Guide References 1 32 3 CA Communication Assistant LAN Status LINK for Main Port Indicates the current connection status of the main port reference only Value Range Disconnect Conne...

Страница 140: ...or KX TDE600 Programming Manual References None Feature Guide References 2 4 5 Dynamic Host Configuration Protocol DHCP Assignment IP Address for IPCMPR Card for KX NCP500 KX NCP1000 KX TDE100 KX TDE2...

Страница 141: ...et mask address of the MPR card reference only Value Range 0 255 0 255 0 255 0 255 except 0 0 0 0 and 255 255 255 255 Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR for KX NCP500 KX NC...

Страница 142: ...are version of the IPCMEC card when it is mounted on the MPR card reference only Value Range None Not mounted 2 Standard IPCMEC card 3 Optional IPCMEC card 6M Maintenance Console Location 3 4 1 1 Slot...

Страница 143: ...ve the mouse pointer over the MPR card and click SVM Property Slot Indicates the slot type reference only Value Range Not applicable Maintenance Console Location 3 5 1 1 Slot OPB3 Card Property Progra...

Страница 144: ...een to select the card command Click the desired cell in the column Select the desired cell in the column and then click Command Value Range For sub slot 1 2 Not applicable For sub slot 3 INS Built in...

Страница 145: ...The card is activated OUS The card is not activated Maintenance Console Location 3 5 1 1 Slot OPB3 Card Property Programming Manual References None Feature Guide References None SVM Feature Specifies...

Страница 146: ...an MSG card OGM feature It is possible to use the ESVM card for the SVM feature as an MSG card OGM feature or both Value Range Disable Enable Maintenance Console Location 3 5 1 1 Slot OPB3 Card Proper...

Страница 147: ...n 3 6 1 1 Slot OPB3 Card Property Card Command Programming Manual References None Feature Guide References None OUS Takes the feature out of service Value Range Not applicable Maintenance Console Loca...

Страница 148: ...rences None Feature Guide References None Port Indicates the port number reference only Value Range Port number Maintenance Console Location 3 7 1 1 Slot Port Property Virtual IP Gateway Port Programm...

Страница 149: ...Guide References None Call Distribution Port Group Specifies a call distribution port group to which incoming trunk calls are directed through the virtual VoIP gateway port Value Range 1 16 Maintenan...

Страница 150: ...and Programming Manual References 3 7 1 1 Slot Port Property Virtual IP Gateway Port Feature Guide References None OUS Takes the port out of service Value Range Not applicable Maintenance Console Loca...

Страница 151: ...ming Manual References None Feature Guide References None Call Signalling Model Specifies whether to carry out a call control H 225 process directly between the cards or through a gatekeeper Value Ran...

Страница 152: ...Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Guide References None Primary Gatekeeper Port Number Specifies the port number of...

Страница 153: ...ort number of the secondary gatekeeper Value Range 1 65535 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Guide References None...

Страница 154: ...s the TCP port number for connectionless tunnelling between gateway devices at different locations in a QSIG network Value Range 1 65535 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtua...

Страница 155: ...65000 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Guide References None RTCP Packet Sending Ability Specifies whether to ena...

Страница 156: ...ifies the type of value to be stored in the ToS field of the packet Value Range ToS DSCP HEX Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References N...

Страница 157: ...nces None RTP QoS DSCP Specifies the value in the ToS field by a DSCP for DiffServ Value Range 0 63 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual Refer...

Страница 158: ...eferences 1 31 1 IP Proprietary Telephone IP PT DSP Digital Gain Down Specifies the DSP Digital Gain for the down voice path Value Range 14 6 dB Maintenance Console Location 3 9 1 1 Slot Shelf Propert...

Страница 159: ...Virtual IP Gateway Programming Manual References None Feature Guide References 1 31 1 IP Proprietary Telephone IP PT NLP Setting Specifies the NLP Non Linear Processor setting to control echo sound q...

Страница 160: ...stination extension at another PBX in a QSIG network When using the Centralised VM feature set this to No Value Range No Yes Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway...

Страница 161: ...BX sends dialled digits one at a time Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Guide References 1 30 2 Voice over Internet...

Страница 162: ...nge 0 9 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Guide References None Incoming Call Voice Activity Detection for G 711 En...

Страница 163: ...lf Property Virtual IP Gateway Programming Manual References None Feature Guide References None Voice Codec Priority 2nd Specifies the second highest priority codec type Value Range None G 711A G 711...

Страница 164: ...ms 30 ms 40 ms 50 ms 60 ms Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Guide References None Packet Sampling Time for G 711 S...

Страница 165: ...FAX Detection Ability feature Since fax signals using a codec other than G 711 cannot be received accurately at the destination this feature automatically switches the codec to G 711 to enable end to...

Страница 166: ...2833 Value Range 96 127 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Guide References None T38 FAX Max Datagram Specifies the...

Страница 167: ...ecifies the redundancy count for T 30 messages when using the T 38 protocol Value Range 0 7 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References No...

Страница 168: ...Guide References None Timer T301 Specifies the maximum time that the PBX waits for a reply after making a call Value Range 0 18000 100 ms Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtu...

Страница 169: ...nance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Guide References None T304 Specifies the maximum time allowed between each digit on an...

Страница 170: ...ply after receiving the Release message Value Range 0 600 100 ms Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Guide References...

Страница 171: ...one Feature Guide References None T313 Specifies the maximum time that the PBX waits for a reply after sending the Connect message Value Range 0 600 100 ms Maintenance Console Location 3 9 1 1 Slot Sh...

Страница 172: ...ance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Guide References None T319 Specifies the maximum time that the PBX waits for a reply aft...

Страница 173: ...PBX tries to establish L2 in Permanent mode Value Range 0 3000 100 ms Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Guide Refe...

Страница 174: ...Feature Guide References None 174 PC Programming Manual 3 9 1 1 Slot Shelf Property Virtual IP Gateway...

Страница 175: ...3 10 1 1 Slot Shelf Property Virtual IP Gateway GK Settings Programming Manual References None Feature Guide References None Device Name Specifies the name of the device for programming reference Valu...

Страница 176: ...lf Property Virtual IP Gateway GW Settings Programming Manual References None Feature Guide References None GW IP Address Specifies the IP address of the destination gateway device Value Range 1 0 0 0...

Страница 177: ...Enable TDA Maintenance Console Location 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings Programming Manual References None Feature Guide References None Protocol Specifies the type of prot...

Страница 178: ...re Guide References None Option 1 GW Name Specifies the name of the destination gateway device for programming reference Value Range Max 20 characters Maintenance Console Location 3 11 1 1 Slot Shelf...

Страница 179: ...sound Value Range 10 ms 20 ms 30 ms 40 ms 50 ms 60 ms Maintenance Console Location 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings Programming Manual References None Feature Guide Referen...

Страница 180: ...de References None Option 2 GW Name Specifies the name of the destination gateway device for programming reference Value Range Max 20 characters Maintenance Console Location 3 11 1 1 Slot Shelf Proper...

Страница 181: ...o end fax signal relay over the network Value Range Disable Enable Maintenance Console Location 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings Programming Manual References 3 11 1 1 Slot...

Страница 182: ...rameter is only necessary if DTMF is set to Outband RFC2833 Value Range 96 127 Maintenance Console Location 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings Programming Manual References No...

Страница 183: ...P Gateway DN2IP Programming Manual References None Feature Guide References None Remaining Number of Digits Specifies the number of digits to be dialled following the leading number to access the dest...

Страница 184: ...Console Location 3 12 1 1 Slot Shelf Property Virtual IP Gateway DN2IP Programming Manual References None Feature Guide References None GW No Specifies the number of the destination gateway device Th...

Страница 185: ...ion 3 13 1 1 Slot Shelf Property Virtual IP Gateway Hunt Pattern Programming Manual References None Feature Guide References None Call Distribution Port Group 1st 16th Specifies the number of the call...

Страница 186: ...er Specifies the UDP port used by the V IPEXT card to transmit and receive MGCP Media Gateway Control Protocol data This must be changed if another network application is using the same port To change...

Страница 187: ...yed here click Common Settings and set the desired value Value Range 1024 65024 Maintenance Console Location 3 14 1 1 Slot Card Property Virtual IP Extension Programming Manual References None Feature...

Страница 188: ...urposes and IP PTs cannot be guaranteed to function normally in these circumstances Do not use debugging settings unless instructed to do so To change the value displayed here click Common Settings an...

Страница 189: ...l IP Extension Programming Manual References None Feature Guide References 1 31 1 IP Proprietary Telephone IP PT First Resending Time MGCP Specifies the length of time that the PBX waits before starti...

Страница 190: ...eferences 1 31 1 IP Proprietary Telephone IP PT Echo Canceller Ability Specifies the echo canceller ability time Value Range OFF 48 ms 128 ms Maintenance Console Location 3 14 1 1 Slot Card Property V...

Страница 191: ...Feature Guide References 1 31 1 IP Proprietary Telephone IP PT EC Gain Specifies the Echo Canceller Gain Value Range 14 6 dB Maintenance Console Location 3 14 1 1 Slot Card Property Virtual IP Extensi...

Страница 192: ...ion 3 14 1 1 Slot Card Property Virtual IP Extension Programming Manual References None Feature Guide References 1 31 1 IP Proprietary Telephone IP PT 192 PC Programming Manual 3 14 1 1 Slot Card Prop...

Страница 193: ...e box will show Registration Executing If the registration is successful the dialogue box will show Registration Completed Click Close Once the IP PT is successfully registered the status of the IP PT...

Страница 194: ...Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programming Manual References None Feature Guide References 1 31 1 IP Proprietary Telephone IP PT Port Indicates the port number refe...

Страница 195: ...ming Manual References None Feature Guide References 1 31 1 IP Proprietary Telephone IP PT Connection Indicates the port status reference only This column offers two ways to open the screen to select...

Страница 196: ...y Telephone IP PT IP Phone Registration ID MAC Address Specifies the MAC address of the IP PT This parameter can only be modified when Connection on this screen is set to OUS Value Range 00 00 00 00 0...

Страница 197: ...eference only Value Range Version number Maintenance Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programming Manual References None Feature Guide References 1 31 1 IP Proprietary...

Страница 198: ...nsion Number Specifies the extension number of the port Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programming Manual Refe...

Страница 199: ...vice Fault The port is not communicating with the network Maintenance Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programming Manual References None Feature Guide References 1 31...

Страница 200: ...he value set here as follows When G 722 is selected the priority is G 722 G 711 G 729A When G 711 is selected the priority is G 711 G 729A G 722 is unavailable When G 729A is selected both G 711 and G...

Страница 201: ...val between measurements samples of sound data during a conversation The smaller this number the higher the quality of the transmitted sound Value Range 20 ms 30 ms 40 ms 60 ms Maintenance Console Loc...

Страница 202: ...ommand Programming Manual References 3 15 1 1 Slot Port Property Virtual IP Extension Feature Guide References None OUS Takes the port out of service Value Range Not applicable Maintenance Console Loc...

Страница 203: ...Hold Time Max Specifies the maximum length of time that the PBX holds information on the location of SIP Extensions To change the value displayed here click Common Settings and set the desired value...

Страница 204: ...1 1 Slot Card Property Virtual SIP Extension Programming Manual References None Feature Guide References 1 31 2 SIP Session Initiation Protocol Extension SIP Session Timer Min Specifies the minimum le...

Страница 205: ...ital Gain for the down voice path Value Range 14 6 dB Maintenance Console Location 3 17 1 1 Slot Card Property Virtual SIP Extension Programming Manual References None Feature Guide References 1 31 2...

Страница 206: ...Guide References 1 31 2 SIP Session Initiation Protocol Extension NLP Setting Specifies the NLP Non Linear Processor setting to control echo sound quality Value Range Disable Weak Normal Strong Mainte...

Страница 207: ...ramming Manual References None Feature Guide References 1 31 2 SIP Session Initiation Protocol Extension Port Indicates the port number reference only Value Range Port number Maintenance Console Locat...

Страница 208: ...z A Z Maintenance Console Location 3 18 1 1 Slot Port Property Virtual SIP Extension Port Programming Manual References None Feature Guide References 1 31 2 SIP Session Initiation Protocol Extension C...

Страница 209: ...n Automatic is selected the bearer mode is set to Speech automatically Value Range Automatic Speech Audio Maintenance Console Location 3 18 1 1 Slot Port Property Virtual SIP Extension Port Programmin...

Страница 210: ...ty Virtual SIP Extension Port Programming Manual References None Feature Guide References 1 31 2 SIP Session Initiation Protocol Extension Voice Activity Detection for G 711 Enables the use of the Voi...

Страница 211: ...uring a call and suppressing the packets of silence from being sent to the network Value Range OFF ON Maintenance Console Location 3 18 1 1 Slot Port Property Virtual SIP Extension Port Programming Ma...

Страница 212: ...Port Property Virtual SIP Extension Port Feature Guide References 1 31 2 SIP Session Initiation Protocol Extension OUS Takes the port out of service Value Range Not applicable Maintenance Console Loc...

Страница 213: ...er Specifies the UDP port used by the V IPCS card to transmit and receive MGCP Media Gateway Control Protocol data This must be changed if another network application is using the same port To change...

Страница 214: ...played here click Common Settings and set the desired value Value Range 1024 65024 Maintenance Console Location 3 20 1 1 Slot Card Property Virtual IPCS Programming Manual References None Feature Guid...

Страница 215: ...ugging purposes and IP CSs cannot be guaranteed to function normally in these circumstances Do not use debugging settings unless instructed to do so To change the value displayed here click Common Set...

Страница 216: ...1 Slot Card Property Virtual IPCS Programming Manual References None Feature Guide References None First Resending Time MGCP Specifies the length of time that the PBX waits before starting to resend...

Страница 217: ...ng Manual References None Feature Guide References None Echo Canceller Ability Specifies the echo canceller ability time Value Range OFF 48 ms 128 ms Maintenance Console Location 3 20 1 1 Slot Card Pr...

Страница 218: ...nual References None Feature Guide References None EC Gain Specifies the Echo Canceller Gain Value Range 14 6 dB Maintenance Console Location 3 20 1 1 Slot Card Property Virtual IPCS Programming Manua...

Страница 219: ...aintenance Console Location 3 20 1 1 Slot Card Property Virtual IPCS Programming Manual References None Feature Guide References None PC Programming Manual 219 3 20 1 1 Slot Card Property Virtual IPCS...

Страница 220: ...egistration Executing If the registration is successful the dialogue box will show Registration Completed Click Close Once the IP CS is successfully registered the status of the IP CS will update to s...

Страница 221: ...t number Maintenance Console Location 3 21 1 1 Slot Port Property Virtual IPCS Programming Manual References None Feature Guide References None Port Indicates the port number reference only Value Rang...

Страница 222: ...n click Command Value Range INS The port is in service OUS The port is out of service Fault The port is not communicating with the network Maintenance Console Location 3 21 1 1 Slot Port Property Virt...

Страница 223: ...Address Indicates the current IP address of the IP CS reference only Value Range 1 0 0 0 223 255 255 255 Maintenance Console Location 3 21 1 1 Slot Port Property Virtual IPCS Programming Manual Refere...

Страница 224: ...IPCS Programming Manual References 13 6 11 5 Air Synchronisation Feature Guide References None Option Slot Indicates the slot position reference only Value Range Slot number Maintenance Console Locat...

Страница 225: ...ences None Feature Guide References None Connection Indicates the port status reference only This column offers two ways to open the screen to select the port command Click the desired cell in the col...

Страница 226: ...etween measurements samples of sound data during a conversation The smaller this number the higher the quality of the transmitted sound Value Range 10 ms 20 ms 30 ms 40 ms 50 ms 60 ms Maintenance Cons...

Страница 227: ...of the Voice Activity Detection feature for the G 711 codec This feature conserves bandwidth by detecting silent periods during a call and suppressing the packets of silence from being sent to the net...

Страница 228: ...on Command Programming Manual References 3 21 1 1 Slot Port Property Virtual IPCS Feature Guide References None OUS Takes the port out of service Value Range Not applicable Maintenance Console Locatio...

Страница 229: ...rty Extension Type Programming Manual References None Feature Guide References None SLT Pulse Dial Mode Selects the type of pulse dial transmission appropriate to your area Value Range Normal Sweden N...

Страница 230: ...e Range 8 n n 12 63 ms Maintenance Console Location 3 23 1 1 Slot Card Property Extension Type Programming Manual References None Feature Guide References None SLT Pulse Maximum Break Width Specifies...

Страница 231: ...Range Disable The PBX disconnects the line to prevent placing the call on hold Enable The PBX places the call on consultation hold Maintenance Console Location 3 23 1 1 Slot Card Property Extension T...

Страница 232: ...eature Guide References None DTMF R STD Detection Time Specifies the minimum length that a DTMF tone must be for the PBX to recognise it as a DTMF tone Value Range 2 n n 1 31 ms Maintenance Console Lo...

Страница 233: ...h SLC8 cards Value Range None Caller ID Maintenance Console Location 3 23 1 1 Slot Card Property Extension Type Installation Manual References For KX NCP500 KX NCP1000 None For KX TDE100 KX TDE200 3 6...

Страница 234: ...3 0 4 0 mA Maintenance Console Location 3 23 1 1 Slot Card Property Extension Type Programming Manual References None Feature Guide References None Hook Threshold PD law KX TDE600 only Specifies the c...

Страница 235: ...f number Maintenance Console Location 3 24 1 1 Slot Port Property Extension Port Programming Manual References None Feature Guide References None Slot Indicates the slot position reference only Value...

Страница 236: ...EXT Maintenance Console Location 3 24 1 1 Slot Port Property Extension Port Programming Manual References None Feature Guide References 2 1 1 Extension Port Configuration Telephone Type Indicates the...

Страница 237: ...nd Value Range INS The port is in service OUS The port is out of service Fault The port is not communicating with the PBX Maintenance Console Location 3 24 1 1 Slot Port Property Extension Port Progra...

Страница 238: ...t extension numbers This is called XDP Mode Off XDP disabled The main telephone and sub telephone both have the main telephone s extension number This is called Parallel Mode Maintenance Console Locat...

Страница 239: ...SDN buttons customised for that device will be deleted When you attempt to apply the new settings a warning message is displayed showing the slot and port number for which SDN buttons will be deleted...

Страница 240: ...ill be deleted If you do not wish to delete SDN buttons for this port click Cancel Value Range For KX NCP500 KX NCP1000 KX TDE100 KX TDE200 1 8 For KX TDE600 Location number for DSS Console 1 64 Locat...

Страница 241: ...o Assigns an Air Synchronisation Group number to the CS This setting is only available when DPT Type Type on this screen is set to Normal Value Range None 1 Maintenance Console Location 3 24 1 1 Slot...

Страница 242: ...een is set to DPT DPT S DPT S Hybrid S Hybrid SLT or S Hybrid S DPT This setting is not available for the KX T7200 the KX T7451 APTs or SLTs Value Range A 64 ms 697 Hz 64 ms 852 Hz B 32 ms 697 Hz 32 m...

Страница 243: ...1 1 Slot Port Property Extension Port Feature Guide References None OUS Takes the port out of service This enables a temporary non use of the port for example for the purpose of repair Value Range No...

Страница 244: ...Programming Manual References 3 24 1 1 Slot Port Property Extension Port Feature Guide References None Total Count Indicates the total number of each type of telephone and CS connected to the PBX refe...

Страница 245: ...ocation 3 27 1 1 Slot Port Property CSI F Port KX TDE series only Programming Manual References None Feature Guide References None Slot Indicates the slot position reference only Value Range Slot numb...

Страница 246: ...ion CS is in service OUS The CS is out of service Fault The port is not communicating with the CS Maintenance Console Location 3 27 1 1 Slot Port Property CSI F Port KX TDE series only Programming Man...

Страница 247: ...to the CS Value Range None 1 Maintenance Console Location 3 27 1 1 Slot Port Property CSI F Port KX TDE series only Programming Manual References 13 6 11 5 Air Synchronisation Feature Guide Reference...

Страница 248: ...Port Property CSI F Port KX TDE series only Feature Guide References None OUS Takes the CS out of service This enables a temporary non use of the CS for example for the purpose of repair Value Range N...

Страница 249: ...seizing a trunk before sending the dialled digits to the telephone company This allows the telephone company to have enough time to accept the dialled digits correctly Value Range 0 5 n n 1 16 s Maint...

Страница 250: ...ntenance Console Location 3 29 1 1 Slot Card Property LCO type Programming Manual References None Feature Guide References None Bell Detection Bell Off Detection Timer Specifies the duration of the be...

Страница 251: ...he pulse inter digit pause This allows the telephone company to have enough time to accept the dialled digits correctly Value Range 630 ms 830 ms 1030 ms Maintenance Console Location 3 29 1 1 Slot Car...

Страница 252: ...Feature Guide References None Low Speed Pulse Dial Make Width Specifies the minimum length of the make signal in a low speed pulse dial Low Speed Pulse Dial Pulse Break on this screen determines the...

Страница 253: ...4 n n 4 18 ms Maintenance Console Location 3 29 1 1 Slot Card Property LCO type Programming Manual References 3 30 1 1 Slot Port Property LCO Port Feature Guide References None High Speed Pulse Dial...

Страница 254: ...at is installed on the LCOT card reference only Value Range None Caller ID Card Maintenance Console Location 3 29 1 1 Slot Card Property LCO type Programming Manual References 3 30 1 1 Slot Port Prope...

Страница 255: ...1 Caller ID Caller ID Caller ID FSK Carrier Detection Enables the PBX to detect the carrier when receiving Caller ID To enable this setting Caller ID Caller ID Signalling on this screen should be set...

Страница 256: ...ble Maintenance Console Location 3 29 1 1 Slot Card Property LCO type Programming Manual References None Feature Guide References 1 18 1 Caller ID Caller ID Caller ID FSK Detection Start Timer Specifi...

Страница 257: ...erences 1 18 1 Caller ID Caller ID Caller ID DTMF Start Code 1 and Start Code 2 Selects the DTMF code used to detect the beginning of a Caller ID series Start Code 1 is prior to Start Code 2 Value Ran...

Страница 258: ...ty LCO type Programming Manual References None Feature Guide References 1 18 1 Caller ID Caller ID Caller ID DTMF Information Code PRIVATE OUT OF AREA TECHNICAL REASON UNKNOWN NUMBER RESTRICTED NUMBER...

Страница 259: ...frequency of the pay tone appropriate to your telephone company Value Range 12kHz 16kHz Maintenance Console Location 3 29 1 1 Slot Card Property LCO type Programming Manual References None Feature Gu...

Страница 260: ...ces 1 26 3 Call Charge Services Pay Tone Pay Tone Pulse MAX Specifies the maximum length that a received pay tone signal can be for the PBX to recognise it as a pay tone signal Value Range None 8 n n...

Страница 261: ...e Sending Flash while end talk Enables the PBX to send a flash signal at the end of call to demand a pay tone signal Value Range Disable Enable Maintenance Console Location 3 29 1 1 Slot Card Property...

Страница 262: ...ole Location 3 30 1 1 Slot Port Property LCO Port Programming Manual References None Feature Guide References None Slot Indicates the slot position reference only Value Range Slot number Maintenance C...

Страница 263: ...n and then click Command Value Range INS The port is in service OUS The port is out of service Maintenance Console Location 3 30 1 1 Slot Port Property LCO Port Programming Manual References 3 31 1 1...

Страница 264: ...quired by the PBX to detect a CPC signal on outgoing or incoming trunk calls before disconnecting the line When None is selected here the line will not be disconnected when a CPC signal is not detecte...

Страница 265: ...Manual References None Feature Guide References None Reverse Detection Selects the type of trunk call for which the reverse signal from the telephone company is detected Value Range Disable For no tru...

Страница 266: ...ection Enables the PBX to receive a pay tone signal from the telephone company Value Range Disable Enable Maintenance Console Location 3 30 1 1 Slot Port Property LCO Port Programming Manual Reference...

Страница 267: ...rt Property LCO Port Programming Manual References None Feature Guide References 1 11 7 External Feature Access EFA Disconnect Time Specifies the length of time after a trunk is disconnected during wh...

Страница 268: ...30 1 1 Slot Port Property LCO Port Feature Guide References None OUS Takes the port out of service This enables a temporary non use of the port for example for the purpose of repair Value Range Not a...

Страница 269: ...ature Guide References None ISDN CO QSIG Master QSIG Slave T202 Specifies the maximum time that the PBX waits for a reply after resending the request to use an ISDN line as a TIE line Value Range 0 60...

Страница 270: ...onsole Location 3 32 1 1 Slot Card Property BRI type PRI type Programming Manual References None Feature Guide References None ISDN CO QSIG Master QSIG Slave T302 Specifies the maximum time allowed be...

Страница 271: ...um time allowed between each digit on an outgoing call Applies to overlap sending Value Range 0 3000 100 ms Maintenance Console Location 3 32 1 1 Slot Card Property BRI type PRI type Programming Manua...

Страница 272: ...eferences None ISDN CO QSIG Master QSIG Slave T309 Specifies the length of time that the PBX tries to disconnect the data link before disconnecting the call Value Range 0 3000 100 ms Maintenance Conso...

Страница 273: ...ue Range 0 600 100 ms Maintenance Console Location 3 32 1 1 Slot Card Property BRI type PRI type Programming Manual References None Feature Guide References None ISDN CO QSIG Master QSIG Slave T316 Sp...

Страница 274: ...cifies the maximum time that the PBX waits for a reply after sending the Suspend message Value Range 0 600 100 ms Maintenance Console Location 3 32 1 1 Slot Card Property BRI type PRI type Programming...

Страница 275: ...re Guide References None ISDN CO QSIG Master QSIG Slave T3D9 Specifies the length of time that the PBX tries to disconnect L2 in Call by Call mode Value Range 0 3000 100 ms Maintenance Console Locatio...

Страница 276: ...600 100 ms Maintenance Console Location 3 32 1 1 Slot Card Property BRI type PRI type Programming Manual References None Feature Guide References None ISDN Extension T203 Specifies the length of time...

Страница 277: ...een each digit on an incoming call Applies to overlap receiving Value Range 0 600 100 ms Maintenance Console Location 3 32 1 1 Slot Card Property BRI type PRI type Programming Manual References None F...

Страница 278: ...ISDN Extension T305 Specifies the maximum time that the PBX waits for a reply after sending the DISC disconnection message to ISDN Value Range 0 3000 100 ms Maintenance Console Location 3 32 1 1 Slot...

Страница 279: ...6000 100 ms Maintenance Console Location 3 32 1 1 Slot Card Property BRI type PRI type Programming Manual References None Feature Guide References None ISDN Extension T308 Specifies the maximum time...

Страница 280: ...SDN Extension T310 Specifies the maximum time that the PBX waits for a reply after receiving the Incoming Call Proceeding message Value Range 0 3000 100 ms Maintenance Console Location 3 32 1 1 Slot C...

Страница 281: ...100 ms Maintenance Console Location 3 32 1 1 Slot Card Property BRI type PRI type Programming Manual References None Feature Guide References None ISDN Extension T320 Specifies the maximum time that t...

Страница 282: ...that the PBX tries to establish L2 in Permanent mode Value Range 0 3000 100 ms Maintenance Console Location 3 32 1 1 Slot Card Property BRI type PRI type Programming Manual References None Feature Gui...

Страница 283: ...Feature Guide References None PC Programming Manual 283 3 32 1 1 Slot Card Property BRI type PRI type...

Страница 284: ...Location 3 33 1 1 Slot Port Property BRI Port Programming Manual References None Feature Guide References None Slot Indicates the slot position reference only Value Range Slot number Maintenance Cons...

Страница 285: ...aster For connecting to private network master port Maintenance Console Location 3 33 1 1 Slot Port Property BRI Port Programming Manual References None Feature Guide References 1 21 1 1 Integrated Se...

Страница 286: ...ng Manual References None Feature Guide References None Status Message Specifies whether the Status Message is sent to the network Value Range No Transmission Status Message is not sent When Mandatory...

Страница 287: ...gramming Manual References None Feature Guide References None ISDN CO Parameters for ISDN CO are not applicable for the BRI extension port Shelf KX TDE600 only Indicates the shelf position reference o...

Страница 288: ...in a QSIG network must have a master port on one PBX and a slave port on another PBX ISDN extensions can belong to an incoming call distribution group or idle extension hunting group In this case an...

Страница 289: ...rty BRI Port Programming Manual References 3 34 1 1 Slot Port Property BRI Port Connection Command Feature Guide References None Subscriber Number Specifies the number used as the CLIP number Value Ra...

Страница 290: ...r digit timer expires Overlap The PBX sends dialled digits one at a time Maintenance Console Location 3 33 1 1 Slot Port Property BRI Port Programming Manual References 3 1 1 1 Slot 4 5 2 3 Timers Cou...

Страница 291: ...o P MP Maintenance Console Location 3 33 1 1 Slot Port Property BRI Port Programming Manual References None Feature Guide References None Networking Data Transfer Enables transmission of extension sta...

Страница 292: ...al References None Feature Guide References None Slot Indicates the slot position reference only Value Range Slot number Maintenance Console Location 3 33 1 1 Slot Port Property BRI Port Programming M...

Страница 293: ...e network master port Maintenance Console Location 3 33 1 1 Slot Port Property BRI Port Programming Manual References None Feature Guide References 1 21 1 11 ISDN Extension Connection Indicates the po...

Страница 294: ...g with 0 or 00 This setting is only available when Port Type on this screen is set to Extension Value Range Ring All Extension for MSN Ring all ISDN extensions that are addressed with MSN Ring an Exte...

Страница 295: ...Value Range Shelf number Maintenance Console Location 3 33 1 1 Slot Port Property BRI Port Programming Manual References None Feature Guide References None Slot Indicates the slot position reference...

Страница 296: ...ssigned Value Range CO For connecting to public network Extension For connecting to extension QSIG Slave For connecting to private network slave port QSIG Master For connecting to private network mast...

Страница 297: ...s 6 SwissNET2 7 SwissNET3 8 Euro ISDN Standard 14 France Domestic 19 Finland 20 Norway 27 Australia 51 US National ISDN 2 Maintenance Console Location 3 33 1 1 Slot Port Property BRI Port Programming...

Страница 298: ...1 1 Integrated Services Digital Network ISDN SUMMARY Access Mode Selects the configuration of the BRI port Value Range P P Point to Point P MP Point to multipoint Maintenance Console Location 3 33 1...

Страница 299: ...position reference only Value Range Shelf number Maintenance Console Location 3 33 1 1 Slot Port Property BRI Port Programming Manual References None Feature Guide References None Slot Indicates the...

Страница 300: ...ssigned Value Range CO For connecting to public network Extension For connecting to extension QSIG Slave For connecting to private network slave port QSIG Master For connecting to private network mast...

Страница 301: ...ork Maintenance Console Location 3 33 1 1 Slot Port Property BRI Port Programming Manual References None Feature Guide References 1 30 1 TIE Line Service 1 30 3 Virtual Private Network VPN Calling Par...

Страница 302: ...the numbering plan ID that applies to incoming trunk calls routed through public and private networks Value Range Unknown ISDN Telephony National Standard Private Maintenance Console Location 3 33 1 1...

Страница 303: ...1 1 Slot Port Property BRI Port Programming Manual References None Feature Guide References None Slot Indicates the slot position reference only Value Range Slot number Maintenance Console Location 3...

Страница 304: ...For connecting to extension QSIG Slave For connecting to private network slave port QSIG Master For connecting to private network master port Maintenance Console Location 3 33 1 1 Slot Port Property...

Страница 305: ...I Port Programming Manual References None Feature Guide References 1 21 1 2 Calling Connected Line Identification Presentation CLIP COLP 1 21 1 3 Advice of Charge AOC 1 21 1 5 Call Forwarding CF by IS...

Страница 306: ...ce only Value Range Slot number Maintenance Console Location 3 33 1 1 Slot Port Property BRI Port Programming Manual References None Feature Guide References None Port Indicates the port number refere...

Страница 307: ...e Console Location 3 33 1 1 Slot Port Property BRI Port Programming Manual References None Feature Guide References None Connection Indicates the port status reference only This column offers two ways...

Страница 308: ...BRI Port Programming Manual References None Feature Guide References 1 21 1 10 Completion of Calls to Busy Subscriber CCBS CCBS Delete Digits Specifies the number of digits to delete from the receive...

Страница 309: ...33 1 1 Slot Port Property BRI Port Feature Guide References None OUS Takes the port out of service This enables a temporary non use of the port for example for the purpose of repair Value Range Not a...

Страница 310: ...t Port Property PRI Port Programming Manual References None Feature Guide References None Slot Indicates the slot position reference only Value Range Slot number Maintenance Console Location 3 35 1 1...

Страница 311: ...o private network slave port QSIG Master For connecting to private network master port Maintenance Console Location 3 35 1 1 Slot Port Property PRI Port Programming Manual References None Feature Guid...

Страница 312: ...etection Option Mandatory Send the Status Message when an error Option or Mandatory is detected Maintenance Console Location 3 35 1 1 Slot Port Property PRI Port Programming Manual References None Fea...

Страница 313: ...ual References None Feature Guide References None Line Coding Selects the line coding type of the PRI PCM Pulse Code Modulation for the port This setting is only available when using the PRI23 card Va...

Страница 314: ...only Indicates the shelf position reference only Value Range Shelf number Maintenance Console Location 3 35 1 1 Slot Port Property PRI Port Programming Manual References None Feature Guide References...

Страница 315: ...ve port on another PBX ISDN extensions can belong to an incoming call distribution group or idle extension hunting group In this case an MSN can be assigned Value Range CO For connecting to public net...

Страница 316: ...ual References 3 36 1 1 Slot Port Property PRI Port Connection Command Feature Guide References None Subscriber Number Specifies the number used as the CLIP number Value Range Max 16 digits consisting...

Страница 317: ...he PBX sends dialled digits one at a time Maintenance Console Location 3 35 1 1 Slot Port Property PRI Port Programming Manual References 3 1 1 1 Slot 4 5 2 3 Timers Counters Dial IRNA Recall Tone Dia...

Страница 318: ...ion 11 9 Private Network Feature Guide References 1 30 5 1 Network Direct Station Selection NDSS Loopback Test started by Network Enables a loopback test started from the network side to be performed...

Страница 319: ...icates the slot position reference only Value Range Slot number Maintenance Console Location 3 35 1 1 Slot Port Property PRI Port Programming Manual References None Feature Guide References None Port...

Страница 320: ...aster port Maintenance Console Location 3 35 1 1 Slot Port Property PRI Port Programming Manual References None Feature Guide References None Connection Indicates the port status reference only This c...

Страница 321: ...SN Maintenance Console Location 3 35 1 1 Slot Port Property PRI Port Programming Manual References None Feature Guide References 1 21 1 11 ISDN Extension Network Configuration Shelf KX TDE600 only Ind...

Страница 322: ...Each ISDN connection in a QSIG network must have a master port on one PBX and a slave port on another PBX ISDN extensions can belong to an incoming call distribution group or idle extension hunting gr...

Страница 323: ...ole Location 3 35 1 1 Slot Port Property PRI Port Programming Manual References 3 36 1 1 Slot Port Property PRI Port Connection Command Feature Guide References None Network Type Selects the network t...

Страница 324: ...uide References None Slot Indicates the slot position reference only Value Range Slot number Maintenance Console Location 3 35 1 1 Slot Port Property PRI Port Programming Manual References None Featur...

Страница 325: ...lave port QSIG Master For connecting to private network master port Maintenance Console Location 3 35 1 1 Slot Port Property PRI Port Programming Manual References None Feature Guide References None C...

Страница 326: ...ng Party Number Numbering Plan ID Public Private Selects the numbering plan ID that applies to outgoing trunk calls routed through public and private networks Value Range Unknown ISDN Telephony Nation...

Страница 327: ...ge Unknown ISDN Telephony National Standard Private Maintenance Console Location 3 35 1 1 Slot Port Property PRI Port Programming Manual References None Feature Guide References None Called Party Numb...

Страница 328: ...ort Programming Manual References None Feature Guide References None Slot Indicates the slot position reference only Value Range Slot number Maintenance Console Location 3 35 1 1 Slot Port Property PR...

Страница 329: ...ecting to extension QSIG Slave For connecting to private network slave port QSIG Master For connecting to private network master port Maintenance Console Location 3 35 1 1 Slot Port Property PRI Port...

Страница 330: ...Connected Line Identification Presentation CLIP COLP 1 21 1 3 Advice of Charge AOC 1 21 1 5 Call Forwarding CF by ISDN P P 1 21 1 7 Call Transfer CT by ISDN 1 21 1 8 Three party Conference 3PTY by IS...

Страница 331: ...ts Specifies the number of digits to delete from the received number when receiving a call of the specified type initiated by the CCBS feature from the network CCBS Type on this screen specifies the a...

Страница 332: ...35 1 1 Slot Port Property PRI Port Feature Guide References None OUS Takes the port out of service This enables a temporary non use of the port for example for the purpose of repair Value Range Not a...

Страница 333: ...Guide References None Frame Sequence Selects the type of frame sequence used for communications Value Range D4 ESF Maintenance Console Location 3 37 1 1 Slot Card Property T1 type Programming Manual R...

Страница 334: ...ntenance Console Location 3 37 1 1 Slot Card Property T1 type Programming Manual References None Feature Guide References None LIU Receive Option Selects the receiving level Receive Equalisation of LI...

Страница 335: ...ts after seizing a DDI DID or TIE line before sending the dialled digits to the telephone company or to another PBX This allows the telephone company or the other PBX to have enough time to accept the...

Страница 336: ...1 type Programming Manual References None Feature Guide References None DTMF Tone DTMF Inter digit Pause Specifies the length of the DTMF inter digit pause This allows the telephone company to have en...

Страница 337: ...he DTMF tone to be received Value Range n 42 0 n 0 31 dB Maintenance Console Location 3 37 1 1 Slot Card Property T1 type Programming Manual References None Feature Guide References None Pulse Dial Pu...

Страница 338: ...pulse inter digit pause This allows the telephone company to have enough time to accept the dialled digits correctly Value Range 630 ms 830 ms 1030 ms Maintenance Console Location 3 37 1 1 Slot Card...

Страница 339: ...ial Value Range 8 n n 9 20 ms Maintenance Console Location 3 37 1 1 Slot Card Property T1 type Programming Manual References None Feature Guide References None Pulse Dial Minimum MAKE Width Specifies...

Страница 340: ...EAK Width OPX Specifies the minimum length of the break signal in a flash signal from an SLT connected to an OPX Value Range 8 n n 3 63 ms Maintenance Console Location 3 37 1 1 Slot Card Property T1 t...

Страница 341: ...aintenance Console Location 3 37 1 1 Slot Card Property T1 type Programming Manual References None Feature Guide References None Flash Minimum BREAK Width TIE Specifies the minimum length of the break...

Страница 342: ...Caller ID Start Code Selects the DTMF code used to detect the beginning of a Caller ID series Value Range A D Maintenance Console Location 3 37 1 1 Slot Card Property T1 type Programming Manual Refere...

Страница 343: ...End Code Selects the DTMF code used to detect the end of a Caller ID series Value Range A D Maintenance Console Location 3 37 1 1 Slot Card Property T1 type Programming Manual References None Feature...

Страница 344: ...ocation 3 38 1 1 Slot Port Property T1 Port Programming Manual References None Feature Guide References None Slot Indicates the slot position reference only Value Range Slot number Maintenance Console...

Страница 345: ...lick Command Value Range INS The channel is in service OUS The channel is out of service Fault The channel is not communicating with the network Maintenance Console Location 3 38 1 1 Slot Port Propert...

Страница 346: ...s the channel type Value Range Undefined Not assigned GCOT Ground Start Central Office LCOT Loop Start Central Office DDI DID Direct Dialling In Direct Inward Dialling TIE TIE Line OPX Off Premise Ext...

Страница 347: ...only available when Channel Type on this screen is set to DDI DID Value Range None 80 n n 2 75 ms Maintenance Console Location 3 38 1 1 Slot Port Property T1 Port Programming Manual References None F...

Страница 348: ...None CO Pulse Speed Selects the speed at which pulse dials are sent to the T1 channel Value Range 10 pulse s 20 pulse s Maintenance Console Location 3 38 1 1 Slot Port Property T1 Port Programming Man...

Страница 349: ...expires Wink Sends the dialled digits to the trunk when the wink signal is received Maintenance Console Location 3 38 1 1 Slot Port Property T1 Port Programming Manual References None Feature Guide R...

Страница 350: ...to send a ringback tone to an outside caller when the network cannot send the tone This setting is only available when Channel Type on this screen is set to DDI DID Value Range Disable Enable Maintena...

Страница 351: ...al References None Feature Guide References 1 5 4 7 Pause Insertion 1 5 4 8 Host PBX Access Code Access Code to the Telephone Company from a Host PBX 1 5 4 9 Special Carrier Access Code Flash Time Spe...

Страница 352: ...he PBX cannot seize the line Value Range 0 5 s 1 5 s 2 0 s 4 0 s 12 0 s Maintenance Console Location 3 38 1 1 Slot Port Property T1 Port Programming Manual References None Feature Guide References 1 1...

Страница 353: ...3 38 1 1 Slot Port Property T1 Port Feature Guide References None OUS Takes the channel out of service This enables a temporary non use of the port for example for the purpose of repair Value Range N...

Страница 354: ...le Location 3 40 1 1 Slot Card Property E1 type Programming Manual References None Feature Guide References None Frame Sequence Selects the type of frame sequence for the E1 card Value Range PCM30 PCM...

Страница 355: ...e dialled digits correctly Value Range 32 n n 1 255 ms Maintenance Console Location 3 40 1 1 Slot Card Property E1 type Programming Manual References None Feature Guide References None Answer Detectio...

Страница 356: ...ing level Transmit Pulse Amplitude of LIU reference only Value Range Mode 1 Mode 8 Maintenance Console Location 3 40 1 1 Slot Card Property E1 type Programming Manual References None Feature Guide Ref...

Страница 357: ...F Inter digit Pause Specifies the length of the DTMF inter digit pause Value Range 64 16 n n 0 11 ms Maintenance Console Location 3 40 1 1 Slot Card Property E1 type Programming Manual References None...

Страница 358: ...Slot Card Property E1 type Programming Manual References None Feature Guide References None Pulse Dial Pulse Inter digit Pause Specifies the length of the pulse inter digit pause This allows the telep...

Страница 359: ...References None Feature Guide References None Pulse Dial Maximum BREAK Width Specifies the maximum length of the break signal in a pulse dial Value Range 8 n n 9 20 ms Maintenance Console Location 3...

Страница 360: ...Guide References None Flash Minimum BREAK Width Specifies the minimum length of the break signal in a flash signal sent from an E1 line Value Range 8 n n 3 63 ms Maintenance Console Location 3 40 1 1...

Страница 361: ...s Value Range A D Maintenance Console Location 3 40 1 1 Slot Card Property E1 type Programming Manual References None Feature Guide References 1 18 1 Caller ID Caller ID Caller ID Information End Code...

Страница 362: ...the DTMF code used to detect the end of a Caller ID series Value Range A D Maintenance Console Location 3 40 1 1 Slot Card Property E1 type Programming Manual References None Feature Guide References...

Страница 363: ...nter digit Timer Specifies the pseudo answer time This setting is available only when Option 1 or Option 3 is selected in DR2 Setting Type on this screen Value Range 3 15 Maintenance Console Location...

Страница 364: ...B bit Maintenance Console Location 3 41 1 1 Slot Card Property E1 type Line Signal Setting Programming Manual References None Feature Guide References None Forced Release Enables the PBX to send a for...

Страница 365: ...Value Range Type 1 A bit 0 Type 2 A bit 1 Type 3 B bit 0 Type 4 B bit 1 Type 5 A bit 1 B bit 1 Maintenance Console Location 3 41 1 1 Slot Card Property E1 type Line Signal Setting Programming Manual...

Страница 366: ...ength Answer Specifies the length of an answer signal Value Range 150 ms 600 ms Maintenance Console Location 3 41 1 1 Slot Card Property E1 type Line Signal Setting Programming Manual References None...

Страница 367: ...pecifies the mode for call charge meter pulses Value Range No Detection Meter pulses are not sent or received Outgoing call only Sends a call charge meter pulse for outgoing trunk calls Both calls Sen...

Страница 368: ...lse Value Range 8 n n 1 80 ms Maintenance Console Location 3 41 1 1 Slot Card Property E1 type Line Signal Setting Programming Manual References None Feature Guide References None DSP Gain Adjustment...

Страница 369: ...ces None DSP Gain Adjustment MFC R2 Transmit Specifies the output power of MFC R2 signals sent from the DSP Value Range 31 dB 0 dB Maintenance Console Location 3 41 1 1 Slot Card Property E1 type Line...

Страница 370: ...ramming Manual References None Feature Guide References None Frame Error Detection Error Rate Specifies the number of frame errors per second which the PBX needs to recognise a remote alarm To enable...

Страница 371: ...rd Property E1 type MFC R2 Setting 1 Programming Manual References None Feature Guide References None ANI Service ANI Max digits Specifies the maximum number of digits to be received via ANI when rece...

Страница 372: ...e Location 3 42 1 1 Slot Card Property E1 type MFC R2 Setting 1 Programming Manual References None Feature Guide References None MFC R2 Timer Disappearance Specifies the maximum time that the PBX wait...

Страница 373: ...s the code used to indicate the end of an ANI number Value Range ANI Complete 1 1 15 ANI Complete 2 4 Undefined 1 15 Maintenance Console Location 3 42 1 1 Slot Card Property E1 type MFC R2 Setting 1 P...

Страница 374: ...eferences None Group l Code Assignment End of Digit Timer Specifies the length of time that the PBX waits for further signal before detecting the end of digit of an ANI number Value Range 1 15 Mainten...

Страница 375: ...tively Value Range Undefined Subscriber Operator Collect Call Maintenance Console Location 3 42 1 1 Slot Card Property E1 type MFC R2 Setting 1 Programming Manual References None Feature Guide Referen...

Страница 376: ...Setting 1 Programming Manual References None Feature Guide References None MFC R2 Group 1 E1 MFC R2 Group1 code Specifies the code value of the Group 1 code when the received Group 1 code is Value Ra...

Страница 377: ...gnment ANI Request Specifies the code used to request the telephone company to send an ANI number Value Range 1 15 Maintenance Console Location 3 43 1 1 Slot Card Property E1 type MFC R2 Setting 2 Pro...

Страница 378: ...ming Manual References None Feature Guide References None Group A Code Assignment Set up Speech Path Specifies the setup speech path code sent to the telephone company Value Range Undefined 1 15 Maint...

Страница 379: ...ndefined 1 15 Maintenance Console Location 3 43 1 1 Slot Card Property E1 type MFC R2 Setting 2 Programming Manual References None Feature Guide References None Group A Code Assignment N 1 Request Spe...

Страница 380: ...e Assignment N 3 Request Specifies the code used to request the telephone company to send the N 3 th digit of an ANI number Value Range Undefined 1 15 Maintenance Console Location 3 43 1 1 Slot Card P...

Страница 381: ...ance Console Location 3 43 1 1 Slot Card Property E1 type MFC R2 Setting 2 Programming Manual References None Feature Guide References None Group B Code Assignment Idle 3 Specifies the code used to in...

Страница 382: ...the telephone company that the received number is not defined Value Range Undefined 1 15 Maintenance Console Location 3 43 1 1 Slot Card Property E1 type MFC R2 Setting 2 Programming Manual References...

Страница 383: ...nces None Group B Code Assignment No Billing Specifies the code used to inform the telephone company that the call is not charged Value Range Undefined 1 15 Maintenance Console Location 3 43 1 1 Slot...

Страница 384: ...onsole Location 3 43 1 1 Slot Card Property E1 type MFC R2 Setting 2 Programming Manual References None Feature Guide References None 384 PC Programming Manual 3 43 1 1 Slot Card Property E1 type MFC...

Страница 385: ...ocation 3 44 1 1 Slot Port Property E1 Port Programming Manual References None Feature Guide References None Slot Indicates the slot position reference only Value Range Slot number Maintenance Console...

Страница 386: ...lick Command Value Range INS The channel is in service OUS The channel is out of service Fault The channel is not communicating with the network Maintenance Console Location 3 44 1 1 Slot Port Propert...

Страница 387: ...ange Public Use the DIL DDI DID method to distribute incoming trunk calls Private Use the TIE line service between two or more PBXs Maintenance Console Location 3 44 1 1 Slot Port Property E1 Port Pro...

Страница 388: ...NI Automatic Number Identification numbers from the E1 line Value Range DTMF Pulse MFC R2 Undefined Maintenance Console Location 3 44 1 1 Slot Port Property E1 Port Programming Manual References None...

Страница 389: ...75 ms Maintenance Console Location 3 44 1 1 Slot Port Property E1 Port Programming Manual References None Feature Guide References 1 11 10 Calling Party Control CPC Signal Detection DTMF Width Selects...

Страница 390: ...e trunk is released Value Range 64 n n 1 128 ms Maintenance Console Location 3 44 1 1 Slot Port Property E1 Port Programming Manual References None Feature Guide References None Start Signal Type Sele...

Страница 391: ...Receiving Caller ID from TIE Specifies whether Caller ID information is received when Channel Type on this screen is set to E M P or E M C Value Range No Yes Maintenance Console Location 3 44 1 1 Slo...

Страница 392: ...3 44 1 1 Slot Port Property E1 Port Programming Manual References None Feature Guide References None Answer Wait Timer 60s Selects the length of time that the PBX waits for the called outside party t...

Страница 393: ...al Carrier Access Code Flash Time Specifies the length of a flash signal Value Range None 16 n n 1 255 ms Maintenance Console Location 3 44 1 1 Slot Port Property E1 Port Programming Manual References...

Страница 394: ...Programming Manual References None Feature Guide References 1 11 6 Flash Recall Terminate 394 PC Programming Manual 3 44 1 1 Slot Port Property E1 Port...

Страница 395: ...44 1 1 Slot Port Property E1 Port Feature Guide References None OUS Takes the channel out of service This enables a temporary non use of the channel for example for the purpose of repair Value Range...

Страница 396: ...DID or TIE line before sending the dialled digits to the telephone company or to another PBX This allows the telephone company or the other PBX to have enough time to accept the dialled digits correc...

Страница 397: ...ty EM type KX TDE series only Programming Manual References None Feature Guide References None DTMF Tone DTMF Inter digit Pause Specifies the length of the DTMF inter digit pause This allows the telep...

Страница 398: ...ulse Type Selects the type of pulse dial transmission appropriate to your area Value Range Normal Sweden New Zealand Maintenance Console Location 3 46 1 1 Slot Card Property EM type KX TDE series only...

Страница 399: ...r that the number has been dialled Value Range No Yes Maintenance Console Location 3 46 1 1 Slot Card Property EM type KX TDE series only Programming Manual References None Feature Guide References No...

Страница 400: ...hookswitch flash signals Value Range Disable Enable Maintenance Console Location 3 46 1 1 Slot Card Property EM type KX TDE series only Programming Manual References None Feature Guide References Non...

Страница 401: ...References None Feature Guide References None Line Signal Setting E M P Pulse Length Seizure Selects the length of a seizure pulse Value Range 150 ms 600 ms Maintenance Console Location 3 46 1 1 Slot...

Страница 402: ...n 3 46 1 1 Slot Card Property EM type KX TDE series only Programming Manual References None Feature Guide References None Line Signal Setting E M P Pulse Length E M P Seizure ACK Enables the PBX to wa...

Страница 403: ...ginning of a Caller ID series Value Range A D Maintenance Console Location 3 46 1 1 Slot Card Property EM type KX TDE series only Programming Manual References None Feature Guide References 1 18 1 Cal...

Страница 404: ...to detect the end of a Caller ID series Value Range A D Maintenance Console Location 3 46 1 1 Slot Card Property EM type KX TDE series only Programming Manual References None Feature Guide References...

Страница 405: ...Slot Port Property EM Port KX TDE series only Programming Manual References None Feature Guide References None Slot Indicates the slot position reference only Value Range Slot number Maintenance Conso...

Страница 406: ...lt The channel is not communicating with the network Maintenance Console Location 3 47 1 1 Slot Port Property EM Port KX TDE series only Programming Manual References 3 48 1 1 Slot Port Property EM Po...

Страница 407: ...E series only Programming Manual References None Feature Guide References 1 5 4 4 Dial Type Selection Gain Adjustment Indicates the value for hardware adjustment fixed reference only Value Range 1 Mai...

Страница 408: ...y Programming Manual References None Feature Guide References 1 5 4 4 Dial Type Selection Wink Signal Time Out Specifies the length of time that the PBX waits to receive a wink signal after seizing a...

Страница 409: ...ces None E M TIE Line Type Selects the type of the voice path for an E M line Value Range 2 wires 4 wires Maintenance Console Location 3 47 1 1 Slot Port Property EM Port KX TDE series only Programmin...

Страница 410: ...nces None Send Ringback Tone to Outside Caller Enables the PBX to send a ringback tone to an outside caller when the network cannot send the tone Value Range Disable Enable Maintenance Console Locatio...

Страница 411: ...al References None Feature Guide References 1 5 4 7 Pause Insertion 1 5 4 8 Host PBX Access Code Access Code to the Telephone Company from a Host PBX 1 5 4 9 Special Carrier Access Code Flash Time Spe...

Страница 412: ...the line Value Range 0 5 s 1 5 s 2 0 s 4 0 s 12 0 s Maintenance Console Location 3 47 1 1 Slot Port Property EM Port KX TDE series only Programming Manual References None Feature Guide References 1 1...

Страница 413: ...Property EM Port KX TDE series only Feature Guide References None OUS Takes the channel out of service This enables a temporary non use of the channel for example for the purpose of repair Value Range...

Страница 414: ...X TDE series only Programming Manual References None Feature Guide References None DTMF Tone DTMF Inter digit Pause Specifies the length of the DTMF inter digit pause This allows the telephone company...

Страница 415: ...1 1 Slot Card Property DID type KX TDE series only Programming Manual References None Feature Guide References None Pulse Dial Pulse Inter digit Pause Specifies the length of the pulse inter digit pau...

Страница 416: ...DE series only Programming Manual References None Feature Guide References None Pulse Dial Pulse Maximum BREAK Width Specifies the maximum length of the break signal in a pulse dial Value Range 8 n n...

Страница 417: ...49 1 1 Slot Card Property DID type KX TDE series only Programming Manual References None Feature Guide References None Caller ID Caller ID Start Code Selects the DTMF code used to detect the beginning...

Страница 418: ...amming Manual References None Feature Guide References 1 18 1 Caller ID Caller ID Caller ID End Code Selects the DTMF code used to detect the end of a Caller ID series Value Range A D Maintenance Cons...

Страница 419: ...ot Port Property DID Port KX TDE series only Programming Manual References None Feature Guide References None Slot Indicates the slot position reference only Value Range Slot number Maintenance Consol...

Страница 420: ...vice OUS The port is out of service Fault The port is not communicating with the network Maintenance Console Location 3 50 1 1 Slot Port Property DID Port KX TDE series only Programming Manual Referen...

Страница 421: ...e dials are sent to the line Value Range 10 pulse s 20 pulse s Maintenance Console Location 3 50 1 1 Slot Port Property DID Port KX TDE series only Programming Manual References None Feature Guide Ref...

Страница 422: ...ies only Programming Manual References None Feature Guide References None CPC Detection Time Out DID In DID Specifies the length of time required by the PBX to detect a CPC signal on outgoing or incom...

Страница 423: ...analogue trunk Value Range No Yes Maintenance Console Location 3 50 1 1 Slot Port Property DID Port KX TDE series only Programming Manual References None Feature Guide References None Send Ringback T...

Страница 424: ...e Pause Time Specifies the length of a pause Value Range 1 5 s 2 5 s 3 5 s 4 5 s Maintenance Console Location 3 50 1 1 Slot Port Property DID Port KX TDE series only Programming Manual References None...

Страница 425: ...cifies the length of time after a trunk is disconnected during which the PBX cannot seize the line Value Range 0 5 s 1 5 s 2 0 s 4 0 s 12 0 s Maintenance Console Location 3 50 1 1 Slot Port Property D...

Страница 426: ...roperty DID Port KX TDE series only Feature Guide References None OUS Takes the port out of service This enables a temporary non use of the port for example for the purpose of repair Value Range Not a...

Страница 427: ...ly Programming Manual References 4 5 2 3 Timers Counters Dial IRNA Recall Tone Dial Extension Inter digit 4 18 2 9 System Options Option 2 ISDN en Bloc Dial as End of Dial for en Bloc mode 5 4 3 1 4 D...

Страница 428: ...No Maintenance Console Location 3 52 1 1 Slot Card Property IP Gateway KX TDE series only Programming Manual References None Feature Guide References 1 30 4 3 Call Forwarding CF by QSIG 428 PC Program...

Страница 429: ...ation 3 53 1 1 Slot Port Property IP GW Port KX TDE series only Programming Manual References None Feature Guide References None Slot Indicates the slot position reference only Value Range Slot number...

Страница 430: ...the column Select the desired cell in the column and then click Command Value Range INS The port is in service OUS The port is out of service Fault The port is not communicating with the network Main...

Страница 431: ...operty IP GW Port KX TDE series only Feature Guide References None OUS Takes the port out of service This enables a temporary non use of the port for example for the purpose of repair Value Range Not...

Страница 432: ...ences None Feature Guide References 1 31 1 IP Proprietary Telephone IP PT Subnet Mask Specifies the subnet mask of the card Value Range 0 255 0 255 0 255 0 255 except 0 0 0 0 and 255 255 255 255 Maint...

Страница 433: ...onsiders the IP PT to be unreachable and sets the port status to Fault During operation set between 10 s and 60 s Settings over 60 s and Disable are used for debugging purposes and IP PTs cannot be gu...

Страница 434: ...ferences None Feature Guide References 1 31 1 IP Proprietary Telephone IP PT DSP Digital Gain Up Specifies the DSP Digital Gain for the up voice path Value Range 14 6 dB Maintenance Console Location 3...

Страница 435: ...NLP Setting Specifies the NLP Non Linear Processor setting to control echo sound quality Value Range Disable Weak Maintenance Console Location 3 55 1 1 Slot Card Property IP Extension KX TDE series on...

Страница 436: ...PT Voice RTP UDP Port No Server Specifies the UDP port used by the IP EXT card to transmit and receive RTP Realtime Transfer Protocol data This must be changed if another network application is using...

Страница 437: ...ge 1024 65472 Maintenance Console Location 3 56 1 1 Slot Card Property IP Extension Common Settings KX TDE series only Programming Manual References None Feature Guide References 1 31 1 IP Proprietary...

Страница 438: ...right arrow to select them for registration Click Next 4 If the registration is still in progress the dialogue box will show Registration Executing If the registration is successful the dialogue box w...

Страница 439: ...es the shelf position reference only Value Range Shelf number Maintenance Console Location 3 57 1 1 Slot Port Property IP Extension Port KX TDE series only Programming Manual References None Feature G...

Страница 440: ...ing Manual References None Feature Guide References 1 31 1 IP Proprietary Telephone IP PT Connection Indicates the port status reference only This column offers two ways to open the screen to select t...

Страница 441: ...de References 1 31 1 IP Proprietary Telephone IP PT IP Address Indicates the IP address of the IP PT reference only Value Range 1 0 0 0 223 255 255 255 Maintenance Console Location 3 57 1 1 Slot Port...

Страница 442: ...ms 697 Hz 96 ms 852 Hz Maintenance Console Location 3 57 1 1 Slot Port Property IP Extension Port KX TDE series only Programming Manual References None Feature Guide References 1 31 1 IP Proprietary T...

Страница 443: ...P Codec on this screen is set to G 711 only 20 ms and 30 ms are available Value Range 20 ms 30 ms 40 ms 60 ms Maintenance Console Location 3 57 1 1 Slot Port Property IP Extension Port KX TDE series o...

Страница 444: ...00 only Indicates the shelf position reference only Value Range Shelf number Maintenance Console Location 3 58 1 1 Slot OPB3 Card Property Programming Manual References None Feature Guide References N...

Страница 445: ...rnal Input Output Card ESVM2 2 Channel Simplified Voice Message Card ESVM4 4 Channel Simplified Voice Message Card Maintenance Console Location 3 58 1 1 Slot OPB3 Card Property Installation Manual Ref...

Страница 446: ...ual References 3 59 1 1 Slot OPB3 Card Property Card Command Feature Guide References None Port Number Indicates the port number of the mounted option card reference only Value Range Port number Maint...

Страница 447: ...n Time Specifies the minimum duration of continuous input from the triggered sensor before the PBX recognises the input and makes a sensor call Value Range 32 n n 2 255 ms Maintenance Console Location...

Страница 448: ...Enable Maintenance Console Location 3 58 1 1 Slot OPB3 Card Property Programming Manual References None Feature Guide References 1 17 5 Outgoing Message OGM 1 17 7 Built in Simplified Voice Message SV...

Страница 449: ...Feature Guide References 1 17 5 Outgoing Message OGM 1 17 7 Built in Simplified Voice Message SVM PC Programming Manual 449 3 58 1 1 Slot OPB3 Card Property...

Страница 450: ...ences None Feature Guide References None OUS Takes the card out of service Value Range Not applicable Maintenance Console Location 3 59 1 1 Slot OPB3 Card Property Card Command Programming Manual Refe...

Страница 451: ...KX NCP1000 1 2 1 Optional Equipment For KX TDE100 KX TDE200 1 2 1 Optional Equipment For KX TDE600 1 2 1 Optional Equipment Programming Manual References None Feature Guide References None Delete Assi...

Страница 452: ...plified Voice Message Card ESVM4 4 Channel Simplified Voice Message Card Maintenance Console Location 3 60 1 1 Slot OPB3 Option Card Setup Installation Manual References For KX NCP500 KX NCP1000 1 2 1...

Страница 453: ...Port Doorphone Card DPH2 2 Port Doorphone Card ECHO16 16 Channel Echo Canceller Card EIO4 4 Port External Input Output Card ESVM2 2 Channel Simplified Voice Message Card ESVM4 4 Channel Simplified Voi...

Страница 454: ...e status of the PS will update to show Registered De registration Follow the steps below to de register the PS 1 Click De registration A dialogue box will appear Registered extension numbers and names...

Страница 455: ...nnection Index Indicates the PS number reference only Value Range For KX NCP500 KX NCP1000 1 64 For KX TDE100 KX TDE200 1 128 For KX TDE600 1 512 Maintenance Console Location 3 61 1 2 Portable Station...

Страница 456: ...s XDP Parallel Mode Extension Name Specifies the name of the PS Value Range Max 20 characters Maintenance Console Location 3 61 1 2 Portable Station Programming Manual References 6 10 4 2 1 Portable S...

Страница 457: ...Feature Guide References 1 25 1 Portable Station PS Connection PC Programming Manual 457 3 61 1 2 Portable Station...

Страница 458: ...be assigned automatically when a CS is connected to the PBX Without the Radio System ID PSs cannot be registered System Wireless System ID Indicates the radio system ID used to register a PS reference...

Страница 459: ...Range ISDN Standard mode The CCBS CF CT and Centralised VM features are supported DIL and DID call distribution are available for the D channel T1 LCOT mode DIL and DID call distribution are availabl...

Страница 460: ...US then INS Note If multiple PBXs are used to establish a private network TIE line service QSIG network etc without being connected through the telephone company assign only one PBX as the clock sourc...

Страница 461: ...Section 4 2 System PC Programming Manual 461...

Страница 462: ...and time Values can be entered by clicking the parameter you want to change and typing the new value or by clicking the up down arrows beside the date and time Value Range Year 2000 2099 Month 01 12...

Страница 463: ...provided by the network Value Range Disable ISDN Caller ID FSK SNTP Maintenance Console Location 4 2 2 1 2 Date Time SNTP Daylight Saving Programming Manual References None Feature Guide References 2...

Страница 464: ...ance Console Location 4 2 2 1 2 Date Time SNTP Daylight Saving Programming Manual References None Feature Guide References 2 3 5 Automatic Setup SNTP Time Zone Time Zone for PC Indicates the UTC Coord...

Страница 465: ...1 2 Date Time SNTP Daylight Saving Daylight Saving Programming Manual References 4 2 2 1 2 Date Time SNTP Daylight Saving Feature Guide References 2 3 5 Automatic Setup Start Date Year Month Day Speci...

Страница 466: ...h 1 12 Day 1 31 Maintenance Console Location 4 3 2 1 2 Date Time SNTP Daylight Saving Daylight Saving Programming Manual References 4 2 2 1 2 Date Time SNTP Daylight Saving Feature Guide References 2...

Страница 467: ...g Manual References 4 6 2 4 Week Table 4 9 2 6 1 Numbering Plan Main 5 13 3 5 1 Incoming Call Distribution Group Group Settings Feature Guide References 2 2 5 Operator Features BGM and Music on Hold M...

Страница 468: ...erences 1 13 4 Music on Hold 1 17 4 Background Music BGM 1 17 5 Outgoing Message OGM BGM and Music on Hold Music Source of BGM2 7 for KX NCP series Music Source of BGM3 8 for KX TDE series Card Select...

Страница 469: ...amming Manual References None Feature Guide References 1 13 4 Music on Hold BGM and Music on Hold Sound on Transfer Selects the audio source for Music for Transfer either the same music source chosen...

Страница 470: ...ic Redial Repeat Interval Specifies the length of time between repeated Automatic Redial attempts Value Range 10 n n 1 360 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual Ref...

Страница 471: ...gue trunk is performed Value Range 0 15 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Guide References 1 6 1 4 Last Number Redial Dial Hot Line Pick...

Страница 472: ...t digits must be dialled before the PBX sends a reorder tone Value Range 1 250 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Guide References 1 5 2...

Страница 473: ...logue trunk Value Range 1 15 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Guide References None Dial Analogue CO Call Duration Start Specifies the...

Страница 474: ...Answer Time Day Lunch Break Night Feature Guide References 1 1 1 6 Intercept Routing Recall Hold Recall Specifies the length of time until the holding extension receives a Hold Recall ring or alarm to...

Страница 475: ...hears a Call Park Recall ring Value Range 1 240 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings 6 10 4 2 1 Portable S...

Страница 476: ...sy Line Busy Party Features Tone Length Reorder Tone for PT Handset Specifies the length of time that a reorder tone is heard when using a PT handset The PT will return to idle status when this timer...

Страница 477: ...Location 4 5 2 3 Timers Counters Programming Manual References 7 4 5 3 2 Voice Message DISA Message Feature Guide References 1 17 6 Direct Inward System Access DISA DISA Mute OGM Start Timer after an...

Страница 478: ...ecifies the length of time in which the caller must dial the second digit before the DISA AA Service activates Value Range 0 5 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual...

Страница 479: ...ll rings at the intercept routing destination before being disconnected Value Range 0 60 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References 7 4 5 3 2 Voice Message DI...

Страница 480: ...em Access DISA DISA Progress Tone Continuation Time before Recording Message Specifies the length of time that a progress tone is sent to the manager extension before recording an OGM Value Range 0 60...

Страница 481: ...Programming Manual References 7 1 5 1 Doorphone Feature Guide References 1 17 1 Doorphone Call Doorphone Call Duration Specifies the length of time until an answered doorphone call is disconnected Val...

Страница 482: ...e 1 15 Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Guide References 1 28 4 Timed Reminder Timed Reminder Interval Time Specifies the length of time...

Страница 483: ...onference Recall tone Value Range 60 n n 0 60 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Guide References 1 14 1 2 Conference Unattended Conferen...

Страница 484: ...es None Feature Guide References 1 14 1 2 Conference Miscellaneous Caller ID Waiting to receive Specifies the length of time that the PBX waits to receive Caller ID from an analogue trunk If the Calle...

Страница 485: ...er ID Extension PIN Lock Counter Specifies the number of successive incorrect PIN entries allowed before the extension PIN is locked A locked extension PIN can not be used until reset from the extensi...

Страница 486: ...cation 4 5 2 3 Timers Counters Programming Manual References 12 3 10 3 DDI DID Table Feature Guide References 1 1 1 3 Direct Inward Dialling DID Direct Dialling In DDI Incoming Call Inter digit Timer...

Страница 487: ...ngoing call after air synchronisation is lost Value Range 60 n n 0 300 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References 13 6 11 5 Air Synchronisation Feature Guide...

Страница 488: ...l References None Feature Guide References None During Conversation DTMF Inter digit Pause Specifies the length of time between DTMF signals when numbers are dialled in succession from a PT or PS duri...

Страница 489: ...the cell station Value Range 0 s 4 s 8 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References 4 18 2 9 System Options System Wireless Out of Range Registration Feature G...

Страница 490: ...mplified Voice Message SVM Conference Group Call Ring Duration Specifies the length of time that a conference group call will ring The conference group call will be established with members who answer...

Страница 491: ...me Table 1 Select the desired Time Table from the Time Table No list When in Automatic Switching mode the time modes of the tenant are switched as programmed in the corresponding Time Table Manual swi...

Страница 492: ...ences None Feature Guide References 2 2 3 Tenant Service 2 2 4 Time Service 1 Day Lunch Night Day1 Start Lunch Start Day2 Start Night Start Hour Minute Specifies the start time for each time block Tim...

Страница 493: ...Start Setting is set to Enable Value Range 00 00 23 59 Maintenance Console Location 4 7 2 4 Week Table Time Setting Programming Manual References None Feature Guide References 2 2 3 Tenant Service 2...

Страница 494: ...Programming Manual References None Feature Guide References 2 2 3 Tenant Service 2 2 4 Time Service 494 PC Programming Manual 4 7 2 4 Week Table Time Setting...

Страница 495: ...Range Disable Enable Maintenance Console Location 4 8 2 5 Holiday Table Programming Manual References None Feature Guide References 2 2 4 Time Service Holiday Table Start Date Month Specifies the mont...

Страница 496: ...e Range 1 12 Maintenance Console Location 4 8 2 5 Holiday Table Programming Manual References None Feature Guide References 2 2 4 Time Service Holiday Table End Date Day Specifies the day of the holid...

Страница 497: ...mbers and floating extension numbers Value Range Max 3 digits consisting of 0 9 Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 5 13 3 5 1 Incoming Call Distri...

Страница 498: ...Numbering Plan Main Programming Manual References 4 4 2 2 Operator BGM 8 6 6 6 Tenant Feature Guide References 2 2 5 Operator Features Idle Line Access Local Access Specifies the feature number used t...

Страница 499: ...ecifies the feature number used to make a TIE line call Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 11 1 9 1...

Страница 500: ...Dial Feature Guide References 1 6 1 5 Speed Dialling Personal System Personal Speed Dialling Programming Specifies the feature number used to programme Personal Speed Dialling numbers at an extension...

Страница 501: ...Programming Manual References 5 10 3 4 Paging Group Feature Guide References 1 16 1 Paging External BGM On Off Specifies the feature number available for manager extensions used to turn on or off the...

Страница 502: ...ine Access Specifies the feature number used to make a trunk call using a certain trunk Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Progra...

Страница 503: ...Pickup Directed Call Pickup Specifies the feature number used to answer a call ringing at a certain extension Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Num...

Страница 504: ...aging group Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 5 10 3 4 Paging Group Feature Guide References 1 16...

Страница 505: ...emote Operation by Other Extension Feature Guide References 1 9 5 Walking COS 1 9 6 Verification Code Entry Wireless XDP Parallel Mode Set Cancel Specifies the feature number used to set or cancel Wir...

Страница 506: ...e Location 4 9 2 6 1 Numbering Plan Main Programming Manual References None Feature Guide References 1 13 1 Call Hold Call Hold Retrieve Specified with a Holding Extension Number Specifies the feature...

Страница 507: ...Held CO Line Number Specifies the feature number used to retrieve a held trunk call from a different extension by specifying the held trunk number Value Range Max 4 digits consisting of 0 9 and Maint...

Страница 508: ...ces 1 17 10 External Relay Control External Feature Access Specifies the feature number used to access the features of a host PBX or the telephone company Value Range Max 4 digits consisting of 0 9 an...

Страница 509: ...R COLR CNIP CONP CNIR CONR CF Rerouting CT CCBS AOC D AOC E 3PTY 3 35 1 1 Slot Port Property PRI Port Supplementary Service COLP CLIR COLR CNIP CONP CNIR CONR CF Rerouting CT CCBS AOC D AOC E E911 3PT...

Страница 510: ...to the network Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 3 33 1 1 Slot Port Property BRI Port ISDN CO Sub...

Страница 511: ...Manual References None Feature Guide References 1 21 1 4 Call Forwarding CF by ISDN P MP 1 21 1 5 Call Forwarding CF by ISDN P P Message Waiting Set Cancel Call Back Specifies the feature number used...

Страница 512: ...g Plan Main Programming Manual References 6 3 4 1 2 Wired Extension FWD DND 6 12 4 2 2 Portable Station FWD DND Feature Guide References 1 3 1 Call Forwarding FWD Do Not Disturb DND FWD DND Set Cancel...

Страница 513: ...tercom calls to an incoming call distribution group Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 5 13 3 5 1 I...

Страница 514: ...4 9 2 6 1 Numbering Plan Main Programming Manual References 5 13 3 5 1 Incoming Call Distribution Group Group Settings Feature Guide References 1 3 Call Forwarding FWD Do Not Disturb DND Features 1 3...

Страница 515: ...sed to use the same extension settings at a new extension Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References None F...

Страница 516: ...1 1 3 3 Call Waiting Automatic Call Waiting Specifies the feature number used to set or cancel a Call Waiting notification from a trunk doorphone or a call via an incoming call distribution group Valu...

Страница 517: ...er or leave Not Ready mode Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 5 13 3 5 1 Incoming Call Distribution...

Страница 518: ...ber Feature Guide References 1 2 2 8 Supervisory Feature Hot Line Pickup Dial Program Set Cancel Specifies the feature number used to set cancel the Hot Line feature or programme the number to be auto...

Страница 519: ...onsole Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 4 4 2 2 Operator BGM Feature Guide References 1 17 4 Background Music BGM Remote Timed Reminder Remote Wakeup Call Specifies...

Страница 520: ...consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 8 2 6 2 Hotel Charge Main SMDR for External Hotel Application 2 Printing Message 1 8 Fea...

Страница 521: ...ger Manager Feature Guide References 2 2 4 Time Service Remote Extension Dial Lock Off Specifies the feature number available for manager extensions used to unlock other extensions using the Extension...

Страница 522: ...res of an extension to the default values Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References None Feature Guide Ref...

Страница 523: ...ture number used to make a conference group call Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 4 5 2 3 Timers...

Страница 524: ...s 4 18 2 9 System Options Option 5 Busy Out Busy Out for Analogue CO Feature Guide References 1 5 4 6 Trunk Busy Out Simplified Voice Message Access Specifies the feature number used to access the SVM...

Страница 525: ...1 TIE Table Leading Number Feature Guide References 1 30 1 TIE Line Service KX T7710 The settings of the MESSAGE button and One touch buttons on the KX T7710 can be programmed Dial Indicates the DTMF...

Страница 526: ...enance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 4 9 2 6 1 Numbering Plan Main Features Message Waiting Set Cancel Call Back Feature Guide References 1 6 1 3 KX T771...

Страница 527: ...en TIE line does not work Specifies whether to check if the quick dial numbering plan is compatible does not overlap with the main numbering plan Value Range Disable Checks whether the quick dial numb...

Страница 528: ...ick Dialling number is used Value Range Max 32 digits consisting of 0 9 T Transfer Secret P Pause and F Flash Maintenance Console Location 4 10 2 6 2 Numbering Plan Quick Dial Programming Manual Refer...

Страница 529: ...C Waiting for Extension Call 6 10 4 2 1 Portable Station Extension Settings Option 2 Manual C Waiting for Extension Call Feature Guide References 1 1 3 3 Call Waiting 1 3 1 3 Do Not Disturb DND 1 8 4...

Страница 530: ...essage Waiting Set Specifies the feature number used to leave a Message Waiting notification Value Range 1 digit 0 9 or Maintenance Console Location 4 11 2 6 3 Numbering Plan B NA DND Call Feature Pro...

Страница 531: ...Override 2 Specifies the feature number used to notify a busy extension of a second call by Call Waiting or call an extension in DND mode This is the same setting as BSS OHCA Whisper OHCA DND Overrid...

Страница 532: ...1 8 4 2 Call Waiting Tone 1 8 4 3 Off hook Call Announcement OHCA 1 8 4 4 Whisper OHCA 532 PC Programming Manual 4 11 2 6 3 Numbering Plan B NA DND Call Feature...

Страница 533: ...Service COS TRS Level Day Lunch Break Night Specifies the Toll Restriction TRS Call Barring Barring level for making trunk calls in each time mode Value Range 1 Allows all trunk calls 2 6 Restricts t...

Страница 534: ...ode Feature Guide References 1 9 3 Extension Dial Lock TRS Level for System Speed Dialling Specifies the TRS Barring level for making a trunk call using System Speed Dialling numbers which overrides t...

Страница 535: ...CO Duration Time 60s on 5 1 3 1 1 Trunk Group TRG Settings Value Range Disable Enable Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References 4 18 2 9 Syste...

Страница 536: ...4 1 1 Wired Extension Extension Settings Main COS 6 3 4 1 2 Wired Extension FWD DND 6 10 4 2 1 Portable Station Extension Settings Main COS 6 12 4 2 2 Portable Station FWD DND Feature Guide Reference...

Страница 537: ...1 21 1 5 Call Forwarding CF by ISDN P P Outgoing CO Call Printout SMDR Enables the automatic recording of information about outgoing trunk calls on SMDR Value Range Disable Enable Maintenance Console...

Страница 538: ...OS Settings Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Main COS 6 5 4 1 4 Wired Extension Flexible Button 6 10 4 2 1 Portable Station Extension Settings Main COS 6 13 4...

Страница 539: ...Settings Main COS Feature Guide References 1 8 4 Second Call Notification to Busy Extension 1 8 4 3 Off hook Call Announcement OHCA 1 8 4 4 Whisper OHCA Transfer to busy Extension w o BSS Operation En...

Страница 540: ...nce Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References None Feature Guide References 1 4 1 4 Hands free Answerback Executive COS Name Specifies the name of the COS...

Страница 541: ...ettings Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Main COS 6 10 4 2 1 Portable Station Extension Settings Main COS Feature Guide References 1 8 2 Executive Busy Overri...

Страница 542: ...or the group to which the extension belongs Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References 5 14 3 5 1 Incoming Call Distribution Group Group Settin...

Страница 543: ...Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Main COS 6 10 4 2 1 Portable Station Extension Settings Main COS Feature Guide References 2 2 6 Manager Features Time Service...

Страница 544: ...at happens when an extension user presses an SDN button while on hook Value Range Enhanced DSS The registered owner extension is called Standard SDN A dial tone is heard Maintenance Console Location 4...

Страница 545: ...buttons on their own extensions using PT programming Value Range Disable Enable Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References None Feature Guide R...

Страница 546: ...le Station Extension Settings Main COS Feature Guide References 1 17 2 Door Open External Relay Access Enables access to external relays Value Range Disable Enable Maintenance Console Location 4 12 2...

Страница 547: ...nge Allow Deny Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Main COS 6 10 4 2 1 Portable Station Ext...

Страница 548: ...e Range Disable Enable Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References 4 12 2 7 1 Class of Service COS Settings CA CA ICD Group Log Out Feature Guid...

Страница 549: ...Service COS Conference Group Call Operation Enables making conference group calls Value Range Disable Enable Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual R...

Страница 550: ...sable Enable Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References None Feature Guide References None 550 PC Programming Manual 4 12 2 7 1 Class of Servic...

Страница 551: ...100 KX TDE200 or 1 96 for KX TDE600 Specifies the available trunk groups Value Range Block blue Non Block Maintenance Console Location 4 13 2 7 2 Class of Service External Call Block Programming Manua...

Страница 552: ...her Extension 1 64 Specifies the combinations of COS levels for which intercom calls are blocked Value Range Block blue Non Block Maintenance Console Location 4 14 2 7 3 Class of Service Internal Call...

Страница 553: ...ies the ring tone pattern for incoming trunk calls Value Range Single Double Triple Option1 Option2 Maintenance Console Location 4 15 2 8 1 Ring Tone Patterns Call from CO Programming Manual Reference...

Страница 554: ...he ring tone pattern for incoming doorphone calls Value Range Single Double Triple S Double Option 1 Option 2 Maintenance Console Location 4 16 2 8 2 Ring Tone Patterns Call from Doorphone Programming...

Страница 555: ...ll from Others Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Option 1 Ring Pattern Table 6 10 4 2 1 Portable Station Extension Settings Option 1 Ring Pattern Table Feature...

Страница 556: ...3 Ring Tone Patterns Call from Others Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Option 1 Ring Pattern Table 6 10 4 2 1 Portable Station Extension Settings Option 1 Ri...

Страница 557: ...Feature Guide References None PC Programming Manual 557 4 17 2 8 3 Ring Tone Patterns Call from Others...

Страница 558: ...play Selects the time format shown on the displays of extensions The time display format assigned here applies when setting the Timed Reminder feature Value Range 12H 24H Maintenance Console Location...

Страница 559: ...Options Programming Manual References 6 3 4 1 2 Wired Extension FWD DND 6 12 4 2 2 Portable Station FWD DND Feature Guide References 1 3 Call Forwarding FWD Do Not Disturb DND Features 1 20 3 LED Indi...

Страница 560: ...When there are separate FWD DND settings for calls from trunks and calls from extensions mode switching cannot be performed Maintenance Console Location 4 18 2 9 System Options Programming Manual Refe...

Страница 561: ...ming Manual References None Feature Guide References 1 11 2 Off hook Monitor PT Operation Privacy Release by SCO key Selects the function of the S CO button during a trunk call Value Range Enable Pres...

Страница 562: ...tion Automatic Answer for Call from CO after Specifies the number of times a PT in Hands free Answerback mode will ring before a conversation is established automatically when it receives a call from...

Страница 563: ...ll Transfer without Announcement feature Value Range Hold Any extension can retrieve a held call Exclusive Hold Only the holding extension can retrieve a held call Maintenance Console Location 4 18 2...

Страница 564: ...References None Feature Guide References 1 28 2 Extension Feature Clear Extension Clear Hot Line Pickup Dial Specifies whether the Hot Line setting is cleared when Extension Feature Clear is performe...

Страница 565: ...mode Specifies whether to automatically send as an end code when dialling to an ISDN line if used as the end code will not be dialled out as part of a number even when the key is pressed Value Range E...

Страница 566: ...alogue CO line is performed when the called party does not answer within a preprogrammed time period Value Range Enable Disable Maintenance Console Location 4 18 2 9 System Options Programming Manual...

Страница 567: ...Call Selects whether the time limit for extension to trunk calls applies to outgoing calls only or for both outgoing and incoming calls COS determines the use of this feature and the length of the ti...

Страница 568: ...Confirmation Tone Tone 1 Called by Voice Enables the PBX to send Confirmation Tone 1 Confirmation Tone 1 is heard from a PT when it receives a call in voice calling mode Value Range Disable Enable Mai...

Страница 569: ...from a doorphone when the doorphone button is pressed Value Range Disable Enable Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Guide References 1 29...

Страница 570: ...onfirmation Tone Confirmation Tone Tone 4 2 Finish Conference Enables the PBX to send Confirmation Tone 4 2 Confirmation Tone 4 2 is heard from an extension when a party leaves a conference call Value...

Страница 571: ...Disable Enable Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Guide References 1 29 1 Dial Tone Dial Tone Dial Tone for Extension Selects the dial ton...

Страница 572: ...8 1 System Setting Feature Guide References 1 10 1 Automatic Route Selection ARS 1 29 1 Dial Tone Echo Cancel Conference Enables the use of the ECHO EECHO card for conference calls Value Range Disable...

Страница 573: ...f the ECHO EECHO card for extension to ISDN T1 E1 line calls If set to Enable the echo canceller card is used for extension to ISDN T1 E1 line calls If set to Disable the echo canceller card is not us...

Страница 574: ...flash when a call arrives and pressing it will pick up the call Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Guide References 1 4 1 3 Call Pickup DS...

Страница 575: ...Enable The PBX places the current call on consultation hold Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Guide References 1 12 1 Call Transfer Trans...

Страница 576: ...PBX 1 and extension 102 is registered at PBX 2 Only the Extension Number Method is supported If disabled different leading numbers need to be assigned for extensions at each PBX Value Range Disable En...

Страница 577: ...e Location 4 18 2 9 System Options Programming Manual References None Feature Guide References 1 2 2 3 Outside Destinations in Incoming Call Distribution Group 1 21 1 2 Calling Connected Line Identifi...

Страница 578: ...ature Guide References 1 30 6 1 PS Roaming by Network ICD Group System Wireless SDN Delayed Ringing with LCD Selects whether call information such as Caller ID is shown on the display of a PDN extensi...

Страница 579: ...Range 1 12 Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Guide References 1 19 1 Message Waiting Whisper OHCA for SLT APT KX T72xx Enables the use of...

Страница 580: ...ut Busy Out for Analogue CO Enables the PBX to automatically set a trunk to Busy Out status when a loop current is not detected preventing that trunk from being used Value Range Disable Enable Mainten...

Страница 581: ...l BGM Paging Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Guide References None ISDN Option Fwd from ISDN to ISDN Specifies whether alert messages ar...

Страница 582: ...of the calling party name when making a call to the ISDN network Value Range Display Facility Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Guide Refe...

Страница 583: ...on with the CTI application software has been lost Value Range 0 10 Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Guide References 1 32 1 Computer Tel...

Страница 584: ...CTI CDR retry interval timer Specifies the length of time until the alive check of CDR is retried when no response is received for Third Party Call Control CTI Value Range 0 60 s Maintenance Console L...

Страница 585: ...None Feature Guide References None CTI Multi PBX Control USB Serial Number Specifies the serial number assigned to this PBX s USB data transfers used when multiple PBXs are connected via USB to one P...

Страница 586: ...DN Key Selects whether to force an extension e g KX NT400 to become idle while having a call held on a PDN SDN button Value Range Enable Disable Maintenance Console Location 4 18 2 9 System Options Pr...

Страница 587: ...l References None Feature Guide References 1 18 1 Caller ID Channel Seizure Signal Bits Specifies the number of seizure bits to send when sending Caller ID information to an SLT Value Range 10 n n 3 4...

Страница 588: ...an SLT Value Range 64 n n 5 35 ms Maintenance Console Location 4 19 2 10 Extension CID Settings Programming Manual References None Feature Guide References 1 18 1 Caller ID Caller ID Signal Type Speci...

Страница 589: ...ID Send Caller ID Date Time to Extension Enables the PBX to send the date and time of an incoming call when sending Caller ID information to an SLT Value Range Disable Enable Maintenance Console Loca...

Страница 590: ...Maintenance Console Location 4 19 2 10 Extension CID Settings Programming Manual References None Feature Guide References 1 18 1 Caller ID FSK Transmission Level Specifies the transmission level for F...

Страница 591: ...rogramming Manual References 5 10 3 4 Paging Group Feature Guide References 1 16 1 Paging Paging EPG 2 External Pager 2 KX TDE series only Specifies the paging volume for External Pager port 2 Value R...

Страница 592: ...B Maintenance Console Location 4 20 2 11 1 Audio Gain Paging MOH Programming Manual References 4 4 2 2 Operator BGM Feature Guide References 1 13 4 Music on Hold 1 17 4 Background Music BGM MOH MOH 2...

Страница 593: ...Console Location 4 21 2 11 2 Audio Gain Card Programming Manual References None Feature Guide References None Down Gain From PBX Specifies the volume for audio signals from the PBX to the selected ty...

Страница 594: ...594 PC Programming Manual 4 21 2 11 2 Audio Gain Card...

Страница 595: ...Section 5 3 Group PC Programming Manual 595...

Страница 596: ...Trunk Group TRG Settings Programming Manual References 12 1 10 1 CO Line Settings Feature Guide References None COS Specifies the COS of the trunk group applied when making a call from a trunk to ano...

Страница 597: ...O Duration Time 60s Specifies the length of time that a trunk to trunk call can be maintained before being disconnected Value Range None 60 n n 1 60 s Maintenance Console Location 5 1 3 1 1 Trunk Grou...

Страница 598: ...1 4 Maintenance Console Location 5 1 3 1 1 Trunk Group TRG Settings Programming Manual References 5 3 3 1 3 Caller ID Modification 12 1 10 1 CO Line Settings Feature Guide References 1 18 1 Caller ID...

Страница 599: ...nk call by silence detection Value Range Disable Enable Maintenance Console Location 5 1 3 1 1 Trunk Group TRG Settings Programming Manual References 7 3 5 3 1 Voice Message DISA System 12 1 10 1 CO L...

Страница 600: ...12 1 10 1 CO Line Settings Feature Guide References 1 17 6 Direct Inward System Access DISA Simplified Voice Message Tone Detection Silence Enables the disconnection of an SVM originated trunk to tru...

Страница 601: ...signal detection Value Range Disable Enable Maintenance Console Location 5 1 3 1 1 Trunk Group TRG Settings Programming Manual References None Feature Guide References 1 17 7 Built in Simplified Voice...

Страница 602: ...s Code to the Telephone Company from a Host PBX Collect Call Reject For Brazil Group Name Specifies the name of the trunk group for programming reference Value Range Max 20 characters Maintenance Cons...

Страница 603: ...ms 2000 ms Maintenance Console Location 5 1 3 1 1 Trunk Group TRG Settings Programming Manual References None Feature Guide References None Collect Call Reject for Brazil Flashing Time Selects the le...

Страница 604: ...nk group assigned to the corresponding priority level Select the blank option to not assign a trunk group to the priority Value Range For KX NCP500 KX NCP1000 KX TDE100 KX TDE200 Trunk Group No 1 64 F...

Страница 605: ...onal call data and 1 long distance code can be programmed Each trunk group can select a table for use Select the desired table from the Modification Table list If the modified number does not contain...

Страница 606: ...type of network numbering plan is Unknown or not specified A maximum of 4 Length of Digits Modification Tables can be programmed Select the desired table from the Modification Table list If the lengt...

Страница 607: ...ded Number for International Specifies the number to be added to the incoming telephone number when the total number of digits exceeds Minimum Caller ID Digits for International Value Range Max 8 digi...

Страница 608: ...ed for sending to the network as a CLIP number A maximum of 4 CLIP Modification Tables can be programmed Select the desired table from the Modification Table list Removed Number of Digits Specifies th...

Страница 609: ...n Programming Manual References 3 35 1 1 Slot Port Property PRI Port Calling Party Number Type of Number Public Private 3 35 1 1 Slot Port Property PRI Port Called Party Number Type of Number Public P...

Страница 610: ...t To assign a set of leading numbers automatically click Auto Assign Leading Number Specifies the leading number to be regarded as the beginning of dialling Value Range Max 32 digits consisting of 0 9...

Страница 611: ...lace of the removed digits Value Range Max 32 digits consisting of 0 9 and Maintenance Console Location 5 4 3 1 4 Dialling Plan Programming Manual References None Feature Guide References 1 21 1 1 Int...

Страница 612: ...ling plan table Value Range Type A 1 N11 2 NXX XXXX 3 1NXX NXX XXXX 4 50 Not stored Type B 1 N11 2 NNX XXXX 3 1NPX NXX XXXX 4 50 Not stored Type C 1 N11 2 NXX XXXX 3 1NNX XXXX 4 1NPX NXX XXXX 5 50 Not...

Страница 613: ...e Programming Manual References None Feature Guide References None Rate Specifies the call charge rate The number of decimal places that can be specified here depends on the value set in Charge Option...

Страница 614: ...le Location 5 7 3 2 User Group Programming Manual References 5 8 3 3 Call Pickup Group 5 10 3 4 Paging Group 6 1 4 1 1 Wired Extension Extension Settings Main User Group 6 10 4 2 1 Portable Station Ex...

Страница 615: ...2 2 3 Tenant Service PC Programming Manual 615 5 7 3 2 User Group...

Страница 616: ...g Manual References 6 1 4 1 1 Wired Extension Extension Settings 6 10 4 2 1 Portable Station Extension Settings Feature Guide References 1 4 1 3 Call Pickup 2 2 2 Group Pickup Group 1st 8th Selects th...

Страница 617: ...Feature Guide References 1 4 1 3 Call Pickup 2 2 2 Group PC Programming Manual 617 5 8 3 3 Call Pickup Group...

Страница 618: ...nsion Settings 6 10 4 2 1 Portable Station Extension Settings Feature Guide References 1 4 1 3 Call Pickup 2 2 2 Group User Group 1 32 for KX NCP500 KX NCP1000 KX TDE100 KX TDE200 or 1 96 for KX TDE60...

Страница 619: ...aracters Maintenance Console Location 5 10 3 4 Paging Group Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings 6 10 4 2 1 Portable Station Extension Settings Feature Guide Refe...

Страница 620: ...Feature Guide References 1 16 1 Paging 2 2 2 Group 620 PC Programming Manual 5 10 3 4 Paging Group...

Страница 621: ...tension Settings 6 10 4 2 1 Portable Station Extension Settings Feature Guide References 1 16 1 Paging 2 2 2 Group User Group 1 32 for KX NCP500 KX NCP1000 KX TDE100 KX TDE200 or 1 96 for KX TDE600 Sp...

Страница 622: ...n Settings Feature Guide References 1 16 1 Paging 2 2 2 Group External Pager 1 Specifies whether the external pager belongs to the corresponding paging group Value Range ON blue OFF Maintenance Consol...

Страница 623: ...External Pager Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings 6 10 4 2 1 Portable Station Extension Settings Feature Guide References 1 16 1 Paging 2 2 2 Group PC Programmi...

Страница 624: ...coming Call Distribution Group Features SUMMARY in the Feature Guide Main Floating Extension Number Specifies the floating extension number of the incoming call distribution group Value Range Max 5 di...

Страница 625: ...of the incoming call distribution group Value Range All Distribution Maintenance Console Location 5 13 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature...

Страница 626: ...2 2 Group Call Distribution Tenant Number Specifies the tenant to which the incoming call distribution group belongs to determine the Time Table and the audio source for the group The tenant number co...

Страница 627: ...4 14 2 7 3 Class of Service Internal Call Block Feature Guide References 1 1 2 2 Internal Call Block CLIP on ICD Group Button Specifies the CLIP number sent to the network when making calls using the...

Страница 628: ...ings Programming Manual References None Feature Guide References None Queuing Busy Destination Day Lunch Break Night Specifies the overflow destination of calls that cannot be queued in each time mode...

Страница 629: ...he floating extension number of the incoming call distribution group Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 5 13 3 5 1 Incoming Call Distribution Group Group Settings...

Страница 630: ...up Group Settings Programming Manual References 4 6 2 4 Week Table Feature Guide References 1 2 2 4 Queuing Feature 1 2 2 6 Overflow Feature Time out Manual Queue Redirection Overflow Time Specifies t...

Страница 631: ...ng Feature Queuing Time Table Floating Extension Number Specifies the floating extension number of the incoming call distribution group Value Range Max 5 digits consisting of 0 9 Maintenance Console L...

Страница 632: ...ming Manual References 4 6 2 4 Week Table Feature Guide References 1 2 2 4 Queuing Feature Queuing Time Table When Extension Ringing Enables the PBX to play messages BGM to the caller according to the...

Страница 633: ...aracters Maintenance Console Location 5 13 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Guide References None Extension No Answer Redirection Time S...

Страница 634: ...nual References None Feature Guide References 1 2 2 7 Log in Log out Maximum No of Busy Extension Specifies the number of extensions that can accept calls simultaneously in the incoming call distribut...

Страница 635: ...le Enable Maintenance Console Location 5 13 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Guide References 1 2 2 5 VIP Call Supervisor Extension Numb...

Страница 636: ...ngs Programming Manual References None Feature Guide References 1 24 2 Voice Mail DTMF Integration Group Log Group FWD Floating Extension Number Specifies the floating extension number of the incoming...

Страница 637: ...mory Value Range 0 100 Maintenance Console Location 5 13 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Guide References 1 18 2 Incoming Call Log Grou...

Страница 638: ...etting Indicates the current FWD status for incoming intercom calls reference only Value Range Off On Maintenance Console Location 5 13 3 5 1 Incoming Call Distribution Group Group Settings Programmin...

Страница 639: ...Programming Manual References None Feature Guide References 1 3 1 2 Call Forwarding FWD PC Programming Manual 639 5 13 3 5 1 Incoming Call Distribution Group Group Settings...

Страница 640: ...rs to another group click Member list copy select the group and click OK Extension Number Specifies the extension number of each member In addition to the extension numbers of PT SLT PS and T1 OPX ext...

Страница 641: ...nsion can accept another call This timer is used when Options Wrap up Timer based on is set to ICD Group Member in 5 16 3 5 3 Incoming Call Distribution Group Miscellaneous Value Range 10 n n 0 300 s...

Страница 642: ...e overflow destination when there is no answer Disconnect Disconnects the line Sequence 01 16 Redirects the call to a different sequence Wait 5 n n 1 16 s If preceded by an OGM plays the Music on Hold...

Страница 643: ...Enhanced Phantom button mode When set to Enhanced Phantom mode creating an ICD Group button at an extension using PT personal programming automatically registers the extension as a member of the relev...

Страница 644: ...gs and 6 10 4 2 1 Portable Station Extension Settings become unavailable Value Range Extension The timer is activated after all calls to or from the extension including a retrieved call on hold ICD Gr...

Страница 645: ...embers to the group click Member List To assign extensions as overflow destinations easily click Destination Setting see 2 1 6 Extension Number Setting Hunting Group Name Specifies the name of the hun...

Страница 646: ...e mode Value Range Max 32 digits consisting of 0 9 T Transfer Secret P Pause and F Flash Maintenance Console Location 5 17 3 6 Extension Hunting Group Programming Manual References None Feature Guide...

Страница 647: ...of 0 9 Maintenance Console Location 5 18 3 6 Extension Hunting Group Member List Programming Manual References 5 17 3 6 Extension Hunting Group Feature Guide References 1 2 1 Idle Extension Hunting E...

Страница 648: ...nces 1 2 2 4 Queuing Feature 1 24 1 Voice Mail VM Group Intercept to Mailbox Enables the PBX to send the mailbox number of the called extension to the VPS when a call is redirected to the VM DPT group...

Страница 649: ...nswered within a programmed time period 2 when the VPS is assigned as the Transfer Recall destination of a certain extension When the VPS receives the mailbox number the VPS answers the call with the...

Страница 650: ...ion 5 20 3 7 2 VM DPT Group Unit Settings Programming Manual References 3 24 1 1 Slot Port Property Extension Port Feature Guide References 1 24 1 Voice Mail VM Group 1 24 3 Voice Mail DPT Digital Int...

Страница 651: ...ss 4 9 2 6 1 Numbering Plan Main Other PBX Extension Feature Guide References 1 24 1 Voice Mail VM Group 1 24 3 Voice Mail DPT Digital Integration 1 30 5 2 Centralised Voice Mail Group Name Specifies...

Страница 652: ...ole Location 5 21 3 7 2 VM DPT Group Unit Settings Member List Programming Manual References DPT Type Type 5 20 3 7 2 VM DPT Group Unit Settings Feature Guide References None Port Indicates the port n...

Страница 653: ...the port reference only Value Range 1 12 Maintenance Console Location 5 21 3 7 2 VM DPT Group Unit Settings Member List Programming Manual References DPT Type Type 5 20 3 7 2 VM DPT Group Unit Settin...

Страница 654: ...sion Name Indicates the name of the extension reference only Value Range Max 20 characters Maintenance Console Location 5 21 3 7 2 VM DPT Group Unit Settings Member List Programming Manual References...

Страница 655: ...the PBX sends to the VPS when the called extension is ringing Value Range Max 4 digits consisting of 0 9 and P pause Maintenance Console Location 5 22 3 8 1 VM DTMF Group System Settings Programming M...

Страница 656: ...4 digits consisting of 0 9 and P pause Maintenance Console Location 5 22 3 8 1 VM DTMF Group System Settings Programming Manual References None Feature Guide References None VM DTMF Status Signal Answ...

Страница 657: ...Status Signal Disconnect Specifies the DTMF status signal the PBX sends to the VPS when the caller hangs up Value Range Max 4 digits consisting of 0 9 and P pause Maintenance Console Location 5 22 3 8...

Страница 658: ...Location 5 22 3 8 1 VM DTMF Group System Settings Programming Manual References None Feature Guide References None VM DTMF Status Signal FWD to Extension Ringback Tone Specifies the DTMF status signa...

Страница 659: ...essage waiting notification from the VPS so that the extension user can retrieve a new message in a certain mailbox without having to dial the mailbox number manually Value Range Max 16 digits consist...

Страница 660: ...System Settings Programming Manual References None Feature Guide References None Timing DTMF Length for VM Specifies the length of DTMF signals the PBX sends to the VPS Value Range 80 ms 160 ms Mainte...

Страница 661: ...ce Console Location 5 22 3 8 1 VM DTMF Group System Settings Programming Manual References None Feature Guide References None Timing Waiting Time before Sending VM DTMF Status Signal Specifies the len...

Страница 662: ...mailbox or in the AA service mode It is also possible to send no DTMF signal to the VPS Value Range None Answer by Mailbox AA Maintenance Console Location 5 22 3 8 1 VM DTMF Group System Settings Pro...

Страница 663: ...Group Group Settings Miscellaneous Programmed Mailbox No 6 1 4 1 1 Wired Extension Extension Settings Option 1 Programmed Mailbox No 6 10 4 2 1 Portable Station Extension Settings Option 1 Programmed...

Страница 664: ...aintenance Console Location 5 23 3 8 2 VM DTMF Group Group Settings Programming Manual References None Feature Guide References 1 24 1 Voice Mail VM Group Group Name Specifies the name of the VM DTMF...

Страница 665: ...sole Location 5 23 3 8 2 VM DTMF Group Group Settings Programming Manual References None Feature Guide References 1 24 2 Voice Mail DTMF Integration PC Programming Manual 665 5 23 3 8 2 VM DTMF Group...

Страница 666: ...VPS Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 5 24 3 8 2 VM DTMF Group Group Settings Member List Programming Manual References 5 23 3 8 2 VM DTMF Group Group Settings F...

Страница 667: ...3 9 PS Ring Group Programming Manual References None Feature Guide References 1 25 2 PS Ring Group Group Name Specifies the name of the PS ring group which will be shown on the display of extensions t...

Страница 668: ...ge Caller ID Called Number Maintenance Console Location 5 25 3 9 PS Ring Group Programming Manual References None Feature Guide References 1 25 2 PS Ring Group 668 PC Programming Manual 5 25 3 9 PS Ri...

Страница 669: ...er Specifies the extension number of the PS assigned to the PS Ring Group Value Range Max 5 digits Maintenance Console Location 5 26 3 9 PS Ring Group Member List Programming Manual References 5 25 3...

Страница 670: ...ame of the conference group Value Range Max 20 characters Maintenance Console Location 5 27 3 10 Conference Group Programming Manual References None Feature Guide References 1 15 1 Conference Group Ca...

Страница 671: ...talk feature allows PS users to speak during the call by pressing any of their dial keys Value Range Disable Enable Maintenance Console Location 5 27 3 10 Conference Group Programming Manual Reference...

Страница 672: ...al Number Specifies the destination number of each member of the conference group Value Range Max 32 digits consisting of 0 9 Secret and P Pause Maintenance Console Location 5 28 3 10 Conference Group...

Страница 673: ...Section 6 4 Extension PC Programming Manual 673...

Страница 674: ...utton settings To assign a set of CLIP numbers automatically click CLIP Generate Main Extension Number Specifies the extension number of the extension Value Range Max 5 digits consisting of 0 9 Mainte...

Страница 675: ...ture Guide References None Slot Indicates the slot position of each extension card reference only Value Range Slot number Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Prog...

Страница 676: ...rogramming Manual References None Feature Guide References 2 1 1 Extension Port Configuration Telephone Type Indicates the type of telephone connected to the extension port reference only Value Range...

Страница 677: ...nants call pickup groups and paging groups Value Range For KX NCP500 KX NCP1000 KX TDE100 KX TDE200 1 32 For KX TDE600 1 96 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Pr...

Страница 678: ...ping PINs secret b Selecting complex random PINs that cannot be easily guessed c Changing PINs frequently Value Range Max 10 digits consisting of 0 9 Maintenance Console Location 6 1 4 1 1 Wired Exten...

Страница 679: ...ing DND Note that Intercept Routing Busy calls are routed using Intercept Destination When Called Party is Busy below Value Range Max 32 digits consisting of 0 9 Secret and P Pause Maintenance Console...

Страница 680: ...ension Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 25 1 1 Slot Port Property Extension Port Con...

Страница 681: ...ters Dial IRNA Recall Tone Intercept Routing No Answer IRNA Day Lunch Break Night Feature Guide References 1 1 1 6 Intercept Routing ISDN CLIP Extension Number Specifies the extension number of the ex...

Страница 682: ...ion Presentation CLIP COLP CLIP on Extension CO Selects the CLIP number to show on the called party s telephone Value Range Extension Show the CLIP number specified in CLIP ID on the Option 1 tab CO S...

Страница 683: ...Connected Line Identification Presentation CLIP COLP COLR Specifies whether to restrict the display of the CLIP number of the extension on the caller s telephone display when answering a call Value Ra...

Страница 684: ...tension number of the PS with which Wireless XDP Parallel Mode is established To enable Wireless XDP Parallel Mode the PS must be turned off once and then turned on after assigning this setting When c...

Страница 685: ...Voice Processing Systems VPS with DTMF Integration Value Range Max 16 digits consisting of 0 9 and Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual Referenc...

Страница 686: ...amming Manual References 10 6 8 5 Carrier Feature Guide References 1 9 6 Verification Code Entry 1 10 1 Automatic Route Selection ARS Option 2 Extension Number Specifies the extension number of the ex...

Страница 687: ...lt in speaker W OHCA Voice from the handset Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Guide References 1 1 3 3 Call Waiting 1...

Страница 688: ...Recall Tone Dial Hot Line Pickup Dial Start Feature Guide References 1 6 1 7 Hot Line Pickup Dial No Specifies the number to be dialled automatically after going off hook when the Hot Line feature is...

Страница 689: ...s consisting of 0 9 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 25 1 1 Slot Port Property Extension Port Connection Command Feature Guide...

Страница 690: ...utive Override Deny Specifies whether calls can be interrupted by other extensions Value Range Disable Allows other extension users to interrupt an existing call Enable Prevents other extension users...

Страница 691: ...lue Range 0 9999999 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 8 2 6 2 Hotel Charge Feature Guide References 1 9 2 Budget Management Interc...

Страница 692: ...Wired Extension Extension Settings Programming Manual References None Feature Guide References None Outgoing Preferred Line Selects the line to be seized after going off hook to make a call Value Ran...

Страница 693: ...ng Line The longest ringing call is selected PDN The call arriving at any PDN button is selected F 1 F 84 The call arriving at a flexible button F 1 F 84 is selected A flexible button customised as a...

Страница 694: ...Answer Mode Specifies whether the extension s mailbox is monitored in Hands free or Private mode Value Range Hands free Monitor through the built in speaker Private Monitor through the handset or the...

Страница 695: ...Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Guide References None Display Language Selects the display language of the extensi...

Страница 696: ...Enables the first line of the display to show the call duration automatically after answering a trunk call Value Range Disable Enable Maintenance Console Location 6 1 4 1 1 Wired Extension Extension S...

Страница 697: ...4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Guide References 1 4 1 4 Hands free Answerback Option 6 Extension Number Specifies the extension number of the exten...

Страница 698: ...on Settings Programming Manual References None Feature Guide References None Flexible Button Programming Mode Specifies whether the extension user can modify all flexible buttons without limitation or...

Страница 699: ...ion Extension Settings Programming Manual References None Feature Guide References None Display Lock SVM Lock Locks or unlocks the Incoming Call Log and Simplified Voice Message Log display i e specif...

Страница 700: ...Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 25 1 1 Slot Port Property Extension Port Connection Command Feature Guide References None Extension Name...

Страница 701: ...uring a trunk conversation Value Range EFA Terminate Flash Recall Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Guide References...

Страница 702: ...l References None Feature Guide References 1 6 1 4 Last Number Redial ISDN Bearer Selects the ISDN bearer mode When Automatic is selected the bearer mode is set automatically depending on the extensio...

Страница 703: ...tension Value Range Max 20 characters Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Guide References None Group CW w o Tone Ring...

Страница 704: ...after the previous unanswered call When receiving two calls in quick succession e g when a call waiting in a queue is directed to an extension immediately after the previous unanswered call stops ring...

Страница 705: ...3 5 3 Incoming Call Distribution Group Miscellaneous Value Range 0 3000 s Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 5 14 3 5 1 Incoming Ca...

Страница 706: ...extension an extension with one or more PDN buttons Value Range Immediate 1 Ring 2 Rings 3 Rings 4 Rings 5 Rings 6 Rings Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Prog...

Страница 707: ...ferred FWD and DND settings can be programmed separately for each extension in 6 3 4 1 2 Wired Extension FWD DND Extension Number Specifies the extension number of the extension Value Range Max 5 digi...

Страница 708: ...g FWD FWD Destination for Call from CO Indicates the forwarding destination of incoming trunk calls reference only Value Range Max 32 digits consisting of 0 9 Secret and P Pause Maintenance Console Lo...

Страница 709: ...Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 6 3 4 1 2 Wired Extension FWD DND Feature Guide References 1 3 1 2 Call Forwarding FWD FWD No Answer Time S...

Страница 710: ...estination via FWD N A or FWD Busy N A Value Range Disable Enable Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 6 3 4 1 2 Wired Extension FWD...

Страница 711: ...s 1 21 1 2 Calling Connected Line Identification Presentation CLIP COLP Location Entry Number to Generate Specifies the number of locations to be programmed A CLIP number will only be assigned to conn...

Страница 712: ...ole Location 6 2 4 1 1 Wired Extension Extension Settings CLIP Generate Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Feature Guide References 1 21 1 2 Calling Connected L...

Страница 713: ...Feature Guide References 1 21 1 2 Calling Connected Line Identification Presentation CLIP COLP PC Programming Manual 713 6 2 4 1 1 Wired Extension Extension Settings CLIP Generate...

Страница 714: ...6 3 4 1 2 Wired Extension FWD DND Programming Manual References None Feature Guide References 1 3 1 1 Call Forwarding FWD Do Not Disturb DND SUMMARY Forward DND For internal calls Specifies the FWD D...

Страница 715: ...ed Dialling number to call using the Personal Speed Dialling Directory shown on the extension s display Value Range Max 20 characters Maintenance Console Location 6 4 4 1 3 Wired Extension Speed Dial...

Страница 716: ...tons see 1 20 2 Flexible Buttons in the Feature Guide Display Option Key Setting Type Specifies the feature to be assigned to the flexible button Value Range Not Stored Loop CO Single CO Group CO DSS...

Страница 717: ...0 1 96 Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Guide References 1 5 5 3 Trunk Access Parameter Selection for Call Park Specifi...

Страница 718: ...5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Guide References 1 2 2 7 Log in Log out Parameter Selection for Time Service Selects which time modes are switched ma...

Страница 719: ...KX NCP500 KX NCP1000 KX TDE100 KX TDE200 1 8 For KX TDE600 1 32 Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Guide References 2 2 4...

Страница 720: ...g extension number of an incoming call distribution group to be accessed Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming M...

Страница 721: ...ed Extension Flexible Button Programming Manual References None Feature Guide References 1 3 Call Forwarding FWD Do Not Disturb DND Features Extension Number for Group Fwd External Specifies the float...

Страница 722: ...number of an incoming call distribution group for which call log information is displayed If the cell is left empty the extension will display its own call log information Value Range Max 5 digits con...

Страница 723: ...nces None Feature Guide References 1 2 2 4 Queuing Feature Extension Number for Two way Record Specifies the floating extension number of the VM DPT group containing the extension s mailbox Value Rang...

Страница 724: ...on 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Guide References 1 24 2 Voice Mail DTMF Integration 1 24 3 Voice Mail DPT Digital Integration Extension Number f...

Страница 725: ...a maximum of 2000 with the KX NCP500 KX NCP1000 KX TDE100 KX TDE200 or 5000 with the KX TDE600 One touch Dialling buttons for extensions and DSS Consoles Value Range Max 32 digits consisting of 0 9 T...

Страница 726: ...ecret P Pause and F Flash Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Guide References 1 30 5 1 Network Direct Station Selection N...

Страница 727: ...ge KX DT300 series except KX DT321 KX T7600 series except KX T7665 IP PT except KX NT265 KX NT321 1 30 KX DT321 KX T7665 KX NT265 KX NT321 1 8 Even if ring tone 9 30 is selected ring tone 1 is heard O...

Страница 728: ...ue Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Guide References 1 24 3 Voice Mail DPT Digital...

Страница 729: ...Fwd Both Extension Number for Group Fwd External Extension Number for Group Fwd Internal Extension Number for Call Log Extension Number for Log in Log out Extension Number for Hurry up Extension Numbe...

Страница 730: ...atic Manual Parameter Selection for SDN Feature Guide References None Parameter 2 This parameter is equivalent to Optional Parameter Ringing Tone Type Number on the Key Setting screen Maintenance Cons...

Страница 731: ...on Value Range Max 20 characters Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Guide References None Colour of Font Specifies the co...

Страница 732: ...size of the font on the label for the corresponding button Value Range 4 15 Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Guide Refe...

Страница 733: ...intenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Guide References None PC Programming Manual 733 6 5 4 1 4 Wired Extension Flexible Butto...

Страница 734: ...extensions can be selected To select all extensions at once click Select All When selecting multiple extensions note that if the source extension has an SDN button the copy operation cannot be perfor...

Страница 735: ...uch access Value Range Not Stored One Touch Maintenance Console Location 6 7 4 1 5 Wired Extension PF Button Programming Manual References None Feature Guide References 1 20 2 Flexible Buttons Dial Sp...

Страница 736: ...atus data is transmitted over the network for the selected extension This setting is automatically set to ON when the feature is used and can only be manually changed from ON to OFF to cancel data tra...

Страница 737: ...icates the shelf type and or position reference only Value Range For KX NCP500 KX NCP1000 KX TDE100 KX TDE200 Physical Virtual For KX TDE600 Shelf number Virtual Maintenance Console Location 6 9 4 1 7...

Страница 738: ...0 9 Maintenance Console Location 6 9 4 1 7 Wired Extension Simplified Voice Message Programming Manual References 3 61 1 2 Portable Station Feature Guide References None Extension Name Indicates the n...

Страница 739: ...recording space are available for each extension Value Range None Card1 A Card1 B Card2 A Card2 B Maintenance Console Location 6 9 4 1 7 Wired Extension Simplified Voice Message Programming Manual Re...

Страница 740: ...ps click Extension User Group Table See 5 7 3 2 User Group for more details Main Extension Number Indicates the extension number of the PS reference only Value Range Max 5 digits consisting of 0 9 Mai...

Страница 741: ...e PS belongs The extension user group is used to compose tenants call pickup groups and paging groups Value Range For KX NCP500 KX NCP1000 KX TDE100 KX TDE200 1 32 For KX TDE600 1 96 Maintenance Conso...

Страница 742: ...otect the PBX from this kind of fraudulent use we strongly recommend a Keeping PINs secret b Selecting complex random PINs that cannot be easily guessed c Changing PINs frequently Value Range Max 10 d...

Страница 743: ...the Intercept Routing destination of calls in each time mode for Intercept Routing No Answer and Intercept Routing DND Note that Intercept Routing Busy calls are routed using Intercept Destination Whe...

Страница 744: ...outing Intercept No Answer Time Extension Number Indicates the extension number of the PS reference only Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 10 4 2 1 Portable Sta...

Страница 745: ...table Station Extension Settings Programming Manual References 4 5 2 3 Timers Counters Dial IRNA Recall Tone Intercept Routing No Answer IRNA Day Lunch Break Night Feature Guide References 1 1 1 6 Int...

Страница 746: ...onsole Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Guide References 1 21 1 2 Calling Connected Line Identification Presentation CLIP COLP CLIP on...

Страница 747: ...ange Disable Enable Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Guide References 1 21 1 2 Calling Connected Line Identificati...

Страница 748: ...ne Extension Name Specifies the name of the PS Value Range Max 20 characters Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 61 1 2 Portable...

Страница 749: ...2 1 Portable Station Extension Settings Programming Manual References None Feature Guide References 1 24 2 Voice Mail DTMF Integration Transfer Recall Destination Specifies the transfer recall destin...

Страница 750: ...Code Entry 1 10 1 Automatic Route Selection ARS Option 2 Extension Number Indicates the extension number of the PS reference only Value Range Max 5 digits consisting of 0 9 Maintenance Console Locati...

Страница 751: ...ces 1 1 3 3 Call Waiting Automatic C Waiting Specifies whether to receive call waiting notification for a call from trunk a doorphone call or a call via an incoming call distribution group Value Range...

Страница 752: ...Range Max 32 digits consisting of 0 9 T Transfer Secret P Pause and F Flash Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Guide...

Страница 753: ...ther extension users to pick up calls to your PS Enable Prevents other extension users from picking up calls to your PS Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Prog...

Страница 754: ...one Feature Guide References 1 19 2 Absent Message Charge Limit Specifies the maximum limit of call charges allowed for the PS When this limit is reached the PS cannot be used to make further trunk ca...

Страница 755: ...ettings Programming Manual References 3 61 1 2 Portable Station Extension Name Feature Guide References None Outgoing Preferred Line Selects the line to be seized after going off hook to make a call V...

Страница 756: ...Line The longest ringing call is selected PDN The call arriving at any PDN button is selected F 1 F 12 The call arriving at a flexible button F 1 F 12 is selected A flexible button customised as a Si...

Страница 757: ...ual References None Feature Guide References 1 24 3 Voice Mail DPT Digital Integration Option 5 Extension Number Indicates the extension number of the PS reference only Value Range Max 5 digits consis...

Страница 758: ...able Station Extension Settings Programming Manual References None Feature Guide References 1 20 4 Display Information Incoming Call Display Selects which caller information is shown on the first line...

Страница 759: ...mation Option 6 Extension Number Indicates the extension number of the PS reference only Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 10 4 2 1 Portable Station Extension S...

Страница 760: ...ch Dial Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Guide References 1 6 1 2 One touch Dialling SVM Lock Selects whether Simp...

Страница 761: ...ifies the name of the PS Value Range Max 20 characters Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 61 1 2 Portable Station Extension Nam...

Страница 762: ...all Terminate 1 11 7 External Feature Access EFA Incoming Call Log Memory Specifies the number of incoming trunk calls that are retained in the PS s Incoming Call Log memory Value Range 0 100 Maintena...

Страница 763: ...h Audio Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Guide References 1 21 1 1 Integrated Services Digital Network ISDN SUMMAR...

Страница 764: ...hat the extension goes on hook for the previous call Value Range Disable Enable Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature G...

Страница 765: ...n number of the PS reference only Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 61 1 2 Portable...

Страница 766: ...Value Range Disable Basic Only Enable Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 4 1 1 Slot Card Property IPCMPR for KX NCP500 KX NCP10...

Страница 767: ...gs Programming Manual References 3 61 1 2 Portable Station Extension Name Feature Guide References None FWD Mode for Call from CO Indicates the forwarding type of incoming trunk calls reference only V...

Страница 768: ...ference only Value Range None FWD All FWD Busy FWD N A FWD Busy N A Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 6 12 4 2 2 Portable Statio...

Страница 769: ...ion FWD DND Feature Guide References 1 3 1 2 Call Forwarding FWD Keep ring after FWD NA to CO Specifies whether a PS continues to ring after forwarding an incoming call to an outside destination via F...

Страница 770: ...es 1 21 1 2 Calling Connected Line Identification Presentation CLIP COLP Location Entry Number to Generate Specifies the number of locations to be programmed A CLIP number will only be assigned to reg...

Страница 771: ...Location 6 11 4 2 1 Portable Station Extension Settings CLIP Generate Programming Manual References 6 10 4 2 1 Portable Station Extension Settings Feature Guide References 1 21 1 2 Calling Connected...

Страница 772: ...Feature Guide References 1 21 1 2 Calling Connected Line Identification Presentation CLIP COLP 772 PC Programming Manual 6 11 4 2 1 Portable Station Extension Settings CLIP Generate...

Страница 773: ...able Station FWD DND Programming Manual References None Feature Guide References 1 3 1 1 Call Forwarding FWD Do Not Disturb DND SUMMARY Forward DND For internal calls Specifies the FWD DND setting for...

Страница 774: ...al Group Fwd Both Group Fwd External Group Fwd Internal Account Conference Terminate EFA Charge Call Park Log in Log out Hurry up Wrap up Time Service TRS Level Change ISDN Service CLIR COLR ISDN Hold...

Страница 775: ...Park Specifies whether a call is parked in an idle parking zone automatically or in a specific parking zone Value Range Automatic Specific Maintenance Console Location 6 13 4 2 3 Portable Station Fle...

Страница 776: ...ight Lunch Break Day Night Break Day Night Lunch Day Night Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual References None Feature Guide References 2 2 4 Ti...

Страница 777: ...n SDN button The value specified here is only used when System Wireless SDN Delayed Ringing with LCD on 4 18 2 9 System Options is set to Enable Value Range Immediate 1 Ring 2 Rings 3 Rings 4 Rings 5...

Страница 778: ...ible Button Programming Manual References None Feature Guide References None Extension Number for Message Waiting Specifies the number of an extension or floating extension number of an incoming call...

Страница 779: ...tension number of an incoming call distribution group for which trunk calls are forwarded Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 13 4 2 3 Portable Station Flexible B...

Страница 780: ...Feature Guide References None Extension Number for Hurry up Specifies the floating extension number of the incoming call distribution group whose longest waiting call will be redirected Manual Queue...

Страница 781: ...x 5 digits consisting of 0 9 Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual References None Feature Guide References 1 24 3 Voice Mail DPT Digital Integrat...

Страница 782: ...s 1 7 1 Primary Directory Number PDN Secondary Directory Number SDN Extension Extension Name Indicates the name of the extension when an extension number is specified reference only Value Range Max 20...

Страница 783: ...Feature Guide References 1 21 1 12 ISDN Service Access by Keypad Protocol Dial for NDSS Specifies the network extension number of the extension to be accessed using Network Direct Station Selection No...

Страница 784: ...hen a Call Park button with Parameter Selection for Call Park on this screen set to Specific is pressed Value Range 0 99 Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Progra...

Страница 785: ...ter is equivalent to Extension Number on the Key Setting screen Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual References 6 13 4 2 3 Portable Station Flexi...

Страница 786: ...cation 6 13 4 2 3 Portable Station Flexible Button Programming Manual References 6 13 4 2 3 Portable Station Flexible Button Display Option Key Setting Parameter Selection for Single CO Parameter Sele...

Страница 787: ...g Tone Type Number for Call Park Feature Guide References None Mailbox Number This parameter is equivalent to Ext No of Mailbox on the Key Setting screen Maintenance Console Location 6 13 4 2 3 Portab...

Страница 788: ...To select all PSs at once click Select All When selecting multiple extensions note that if the source extension has an SDN button the copy operation cannot be performed Maintenance Console Location 6...

Страница 789: ...s data is transmitted over the network for the selected extension This setting is automatically set to ON when the feature is used and can only be manually changed from ON to OFF to cancel data transm...

Страница 790: ...Console Location 6 16 4 2 5 Portable Station Simplified Voice Message Programming Manual References 3 61 1 2 Portable Station Feature Guide References None Extension Name Indicates the name of the ex...

Страница 791: ...6 16 4 2 5 Portable Station Simplified Voice Message Programming Manual References 3 1 1 1 Slot Feature Guide References 1 17 7 Built in Simplified Voice Message SVM Maximum of SVM Log Specifies the...

Страница 792: ...own list Note that it is necessary to save these settings separately from system data For more information on flexible buttons see 1 20 2 Flexible Buttons in the Feature Guide Pair Extension Specifies...

Страница 793: ...r KX NCP500 KX NCP1000 KX TDE100 KX TDE200 1 128 For KX TDE600 1 640 Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References None Feature Guide References 1 5 5 3 Trunk Access...

Страница 794: ...out Specifies which incoming call distribution groups that the paired extension belongs to are logged in to or logged out from Value Range None The incoming call distribution group is selected manual...

Страница 795: ...on Value Range 1 7 Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References None Feature Guide References 1 9 1 Toll Restriction TRS Call Barring Barring 1 9 4 Dial Tone Transfe...

Страница 796: ...ure Guide References 1 7 1 Primary Directory Number PDN Secondary Directory Number SDN Extension Extension Number for DSS Specifies the number of an extension to be accessed Value Range Max 5 digits c...

Страница 797: ...Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References None Feature Guide References None Extension Number for Group Fwd Both Specifies t...

Страница 798: ...ion group for which intercom calls are forwarded Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References None Feature Guide Reference...

Страница 799: ...rences None Extension Number for Hurry up Specifies the floating extension number of the incoming call distribution group whose longest waiting call will be redirected Manual Queue Redirection Value R...

Страница 800: ...mailbox Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References None Feature Guide References 1 24 3 Voice Mail DPT Digital Integrat...

Страница 801: ...eature Guide References 1 1 1 2 Direct In Line DIL Extension Name Indicates the name of the extension when an extension number is specified reference only Value Range Max 20 characters Maintenance Con...

Страница 802: ...Feature Guide References 1 21 1 12 ISDN Service Access by Keypad Protocol Dial for NDSS Specifies the network extension number of the extension to be accessed using Network Direct Station Selection No...

Страница 803: ...e Value Range KX DT300 series except KX DT321 KX T7600 series except KX T7665 IP PT except KX NT265 KX NT321 1 30 KX DT321 KX T7665 KX NT265 KX NT321 1 8 Even if ring tone 9 30 is selected ring tone 1...

Страница 804: ...sion each time Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References None Feature Guide References 1 24 3 Voice Mail DPT Digital In...

Страница 805: ...Fwd Both Extension Number for Group Fwd External Extension Number for Group Fwd Internal Extension Number for Call Log Extension Number for Log in Log out Extension Number for Hurry up Extension Numbe...

Страница 806: ...vice Automatic Manual Parameter Selection for SDN Feature Guide References None Parameter 2 This parameter is equivalent to Optional Parameter Ringing Tone Type Number on the Key Setting screen Mainte...

Страница 807: ...nding button Value Range Max 20 characters Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References None Feature Guide References None Colour of Font Specifies the colour used f...

Страница 808: ...eferences None Font Size Specifies the size of the font on the label for the corresponding button Value Range 4 15 Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References None...

Страница 809: ...Programming Manual References None Feature Guide References None PC Programming Manual 809 6 17 4 3 DSS Console...

Страница 810: ...ion DSS Console Select the number of the DSS Console and paired extension Multiple DSS Consoles can be selected To select all DSS Consoles at once click Select All When selecting multiple extensions n...

Страница 811: ...Section 7 5 Optional Device PC Programming Manual 811...

Страница 812: ...ole Location 7 1 5 1 Doorphone Programming Manual References None Feature Guide References 1 17 1 Doorphone Call Physical Location Slot Indicates the slot to which the doorphone is connected reference...

Страница 813: ...amming Manual References None Feature Guide References 1 17 1 Doorphone Call Destination Day Lunch Break Night Specifies the destination number of doorphone calls for each port in each time mode Value...

Страница 814: ...d sets restrictions on intercom calls from certain extensions Internal Call Block Value Range 1 64 Maintenance Console Location 7 1 5 1 Doorphone Programming Manual References 4 12 2 7 1 Class of Serv...

Страница 815: ...Maintenance Console Location 7 1 5 1 Doorphone Programming Manual References None Feature Guide References 1 17 1 Doorphone Call 1 24 3 Voice Mail DPT Digital Integration PC Programming Manual 815 7...

Страница 816: ...e Range Max 5 digits consisting of 0 9 Maintenance Console Location 7 2 5 2 External Pager Programming Manual References None Feature Guide References 1 16 1 Paging 1 17 3 Trunk Answer From Any Statio...

Страница 817: ...nd trunk calls can be made Trunk Intercom calls and TIE line calls without PBX code can be made TIE line calls with PBX code and trunk calls are restricted All All calls are restricted Maintenance Con...

Страница 818: ...s are busy Selects how DISA calls are handled if all DISA ports are currently in use Value Range to Operator to AA 0 to AA 9 Disable Busy Tone Maintenance Console Location 7 3 5 3 1 Voice Message DISA...

Страница 819: ...Message DISA System Programming Manual References 7 3 5 3 1 Voice Message DISA System Option 1 CO CO with DISA Fwd Transfer to Public CO Feature Guide References None CO CO with DISA DISA to Private...

Страница 820: ...rogramming Manual References 7 3 5 3 1 Voice Message DISA System Option 1 CO CO with DISA DISA to Public CO Feature Guide References None CO CO with DISA Fwd Transfer to Private Network Enables trunk...

Страница 821: ...by DTMF Enables a trunk caller to return to the DISA top menu by pressing while hearing a ringback reorder or busy tone If disabled retrying the call is possible by pressing Value Range Disable Enabl...

Страница 822: ...ime Specifies the maximum duration of the cyclic tone that will be recognised by the PBX When the tone sent from the telephone company is shorter than the value set here the PBX recognises it as a ton...

Страница 823: ...g Manual References 3 1 1 1 Slot 3 58 1 1 Slot OPB3 Card Property Feature Guide References None DISA Cyclic Tone Option Repeating Times of ON OFF for Detection Specifies the number of times the tone p...

Страница 824: ...lable on the card To apply changes to this setting follow the steps below 1 Change this setting 2 Set the status of the OPB3 card to OUS then INS Value Range Low About 120 minutes of messages can be r...

Страница 825: ...Voice Message DISA Message Programming Manual References None Feature Guide References 1 17 5 Outgoing Message OGM 1 17 6 Direct Inward System Access DISA Name Specifies the name of the OGM Value Rang...

Страница 826: ...or sets DND Value Range None 1 64 Maintenance Console Location 7 4 5 3 2 Voice Message DISA Message Programming Manual References 7 3 5 3 1 Voice Message DISA System Feature Guide References 1 17 6 Di...

Страница 827: ...Feature Guide References 1 17 8 Automatic Fax Transfer PC Programming Manual 827 7 4 5 3 2 Voice Message DISA Message...

Страница 828: ...ot Feature Guide References 1 17 7 Built in Simplified Voice Message SVM SVM Card No 1 2 Floating Extension Number Specifies the floating extension number used to access the SVM feature Value Range Ma...

Страница 829: ...ded Maintenance Console Location 7 5 5 3 3 Voice Message SVM Programming Manual References 6 9 4 1 7 Wired Extension Simplified Voice Message 6 16 4 2 5 Portable Station Simplified Voice Message Featu...

Страница 830: ...es is optional as specified in SVM Cyclic Tone Option on this screen Maintenance Console Location 7 5 5 3 3 Voice Message SVM Programming Manual References 3 1 1 1 Slot Feature Guide References 1 17 7...

Страница 831: ...or OPB3 card to OUS then INS See 3 5 1 1 Slot OPB3 Card Property or 3 58 1 1 Slot OPB3 Card Property Value Range 20 n n 6 200 ms Maintenance Console Location 7 5 5 3 3 Voice Message SVM Programming Ma...

Страница 832: ...Feature Guide References 1 17 7 Built in Simplified Voice Message SVM 832 PC Programming Manual 7 5 5 3 3 Voice Message SVM...

Страница 833: ...External Relay Programming Manual References None Feature Guide References 1 17 10 External Relay Control Physical Location Shelf KX TDE600 only Indicates the shelf position reference only Value Range...

Страница 834: ...Indicates the port number reference only Value Range Port number Maintenance Console Location 7 6 5 4 External Relay Programming Manual References None Feature Guide References 1 17 10 External Relay...

Страница 835: ...0 External Relay Control COS Number Specifies the Class of Service COS number COS programming determines the extensions that are able to activate relays Value Range 1 64 Maintenance Console Location 7...

Страница 836: ...1 16 For KX TDE600 1 64 Maintenance Console Location 7 7 5 5 External Sensor Programming Manual References None Feature Guide References 1 17 9 External Sensor Physical Location Shelf KX TDE600 only...

Страница 837: ...dicates the port number reference only Value Range Port number Maintenance Console Location 7 7 5 5 External Sensor Programming Manual References None Feature Guide References 1 17 9 External Sensor N...

Страница 838: ...one Feature Guide References 1 17 9 External Sensor Tenant No Specifies the tenant to which the sensor belongs to determine the Time Table for the sensor The tenant number corresponds to the Time Tabl...

Страница 839: ...Section 8 6 Feature PC Programming Manual 839...

Страница 840: ...ammed Whether a tenant uses the basic System Speed Dialling Table or the additional table depends on the setting of System Speed Dial in 8 6 6 6 Tenant Value Range For KX NCP500 KX NCP1000 KX TDE100 K...

Страница 841: ...ies the CLI destination extension to which incoming calls from the programmed telephone number are routed If a Caller ID Modification Table is being used the modified number must match the telephone n...

Страница 842: ...Y 1 27 2 Room Status Control SMDR for External Hotel Application 1 Room Status Control Selects whether check in and check out data is output on SMDR Value Range No Print Print Maintenance Console Loca...

Страница 843: ...e is selected from an extension This character can be used a maximum of seven times in a Printing Message Value Range Max 16 characters Maintenance Console Location 8 2 6 2 Hotel Charge Programming Ma...

Страница 844: ...g for Guest Room Checkout Billing LCD for Minibar Specifies the name of charge item 2 as shown on the display of the hotel operator extension when entering room charges Value Range Max 12 characters M...

Страница 845: ...ters Maintenance Console Location 8 2 6 2 Hotel Charge Programming Manual References None Feature Guide References 1 27 3 Call Billing for Guest Room Checkout Billing Bill SMDR for Minibar Specifies t...

Страница 846: ...the language used for standard items shown on guest bills printed out using the Call Billing feature Value Range Language 1 Language 5 Maintenance Console Location 8 2 6 2 Hotel Charge Programming Ma...

Страница 847: ...est Room Charge Margin Tax Margin Rate for Telephone Specifies the percentage margin to be added to telephone charges displayed on the guest bill Value Range 0 00 99 99 Maintenance Console Location 8...

Страница 848: ...9 99 Maintenance Console Location 8 2 6 2 Hotel Charge Programming Manual References None Feature Guide References 1 27 3 Call Billing for Guest Room Margin Tax Tax Rate for Others Specifies the perce...

Страница 849: ...rrency Specifies the currency characters shown on the display of the extension and the SMDR Value Range Max 3 characters Maintenance Console Location 8 2 6 2 Hotel Charge Programming Manual References...

Страница 850: ...and then the call is disconnected Maintenance Console Location 8 2 6 2 Hotel Charge Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Option 3 Charge Limit 6 10 4 2 1 Portabl...

Страница 851: ...Feature Guide References 1 26 3 Call Charge Services PC Programming Manual 851 8 2 6 2 Hotel Charge...

Страница 852: ...ole Location 8 3 6 3 Verification Code Programming Manual References None Feature Guide References 1 9 6 Verification Code Entry User Name Specifies the user name assigned to the verification code Val...

Страница 853: ...Number Specifies the COS that applies when making a trunk call with the verification code Value Range 1 64 Maintenance Console Location 8 3 6 3 Verification Code Programming Manual References 4 12 2 7...

Страница 854: ...on the verification code The number of decimal places that can be specified here depends on the value set in Charge Options Digits After Decimal Point in 8 2 6 2 Hotel Charge Value Range 0 9999999 Mai...

Страница 855: ...of codes click the applicable tab Second Dial Tone Waiting Code Specifies the Second Dial Tone Waiting code Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 8 4 6 4 Second...

Страница 856: ...maximum of 8 Absent Messages can be programmed and any extension user can select one of them Absent Message Specifies the message for display Value Range Max 16 characters Maintenance Console Location...

Страница 857: ...GM7 Tone For KX TDE series Same as System Setting BGM BGM2 BGM3 BGM4 BGM5 BGM6 BGM7 BGM8 Tone Maintenance Console Location 8 6 6 6 Tenant Programming Manual References 4 4 2 2 Operator BGM Feature Gui...

Страница 858: ...ance Console Location 8 6 6 6 Tenant Programming Manual References 10 1 8 1 System Setting Feature Guide References 1 10 1 Automatic Route Selection ARS 2 2 3 Tenant Service System Speed Dial Specifie...

Страница 859: ...Section 9 7 TRS PC Programming Manual 859...

Страница 860: ...ing digits of the dialled number are not found in the applicable Denied Code Tables the call is made A maximum of 100 denied codes can be programmed for each level 20 codes are displayed at a time To...

Страница 861: ...s checked against the applicable Exception Code Tables and if a match is found the call is made A maximum of 100 exception codes can be programmed for each level 20 codes are displayed at a time To di...

Страница 862: ...um of 20 with the KX NCP500 KX NCP1000 KX TDE100 KX TDE200 or 100 with the KX TDE600 Special Carrier Access Codes can be programmed With the KX TDE600 20 codes are displayed at a time To show other se...

Страница 863: ...egarded A maximum of 10 emergency numbers can be programmed Emergency Number Specifies the numbers used for making emergency calls It is not necessary to start the emergency number with a Trunk Access...

Страница 864: ...re Guide References 1 9 1 Toll Restriction TRS Call Barring Barring TRS Check for Dial Enables a TRS Barring check for the user dialled and This is useful in preventing unauthorised calls which could...

Страница 865: ...es a trunk call If the number of dialled digits exceeds the programmed limit the line will be disconnected Value Range None 1 7 Maintenance Console Location 9 5 7 5 Miscellaneous Programming Manual Re...

Страница 866: ...ny Table 2_N Except Table N_6 The Denied Code Tables for the higher levels are applied to all levels below it and the Exception Code Tables for the lower levels are applied to all levels above it Deny...

Страница 867: ...Section 10 8 ARS PC Programming Manual 867...

Страница 868: ...n user makes a call using Idle Line Access Trunk Access or S CO Line Access method Maintenance Console Location 10 1 8 1 System Setting Programming Manual References None Feature Guide References 1 5...

Страница 869: ...digits of the user dialled number excluding the leading number 100 leading numbers are displayed at a time To display other sets of leading numbers click the applicable tab Leading Number Specifies t...

Страница 870: ...ber Value Range For KX NCP500 KX NCP1000 KX TDE100 KX TDE200 1 16 For KX TDE600 1 48 Maintenance Console Location 10 2 8 2 Leading Number Programming Manual References None Feature Guide References 1...

Страница 871: ...lan Tables and each Routing Plan Table can have its own time blocks Select the desired Routing Plan Table number from the Routing Plan list To adjust the currently displayed Routing Plan click and dra...

Страница 872: ...alue Range Disable Enable Maintenance Console Location 10 4 8 3 Routing Plan Time Time Setting Programming Manual References None Feature Guide References 1 10 1 Automatic Route Selection ARS Time A D...

Страница 873: ...sired day of the week by clicking the applicable tab Time A Time D Specifies the carrier to be given priority for each time zone Value Range For KX NCP500 KX NCP1000 KX TDE100 KX TDE200 None 1 10 For...

Страница 874: ...ole Location 10 6 8 5 Carrier Programming Manual References None Feature Guide References 1 10 1 Automatic Route Selection ARS Removed Number of Digits Specifies the number of leading digits to remove...

Страница 875: ...onsisting of 0 9 and P Pause Maintenance Console Location 10 6 8 5 Carrier Programming Manual References None Feature Guide References 1 10 1 Automatic Route Selection ARS TRG 01 TRG 64 for KX NCP500...

Страница 876: ...ommand in Modify Command on the Carrier tab Authorisation Code for Tenant Tenant 1 Tenant 32 Specifies the Authorisation code of each carrier for each tenant Note For the KX NCP500 KX NCP1000 KX TDE10...

Страница 877: ...fferent leading number exceptions can be programmed 40 leading number exception entries are displayed on the screen at a time To display other sets click the applicable tab Leading Number Exception Sp...

Страница 878: ...groups click the applicable tab Authorisation Code for Trunk Group TRG 01 TRG 64 for KX NCP500 KX NCP1000 KX TDE100 KX TDE200 TRG 01 TRG 96 for KX TDE600 Specifies the Authorisation code of each carri...

Страница 879: ...Section 11 9 Private Network PC Programming Manual 879...

Страница 880: ...played at a time To display other priority sets click the applicable tab Using a private network up to 8 PBXs can share one VPS centralised VM connected to another PBX This VPS can provide voice mail...

Страница 881: ...ces None Feature Guide References 1 30 1 TIE Line Service Added Number Specifies the number to be added to the dialled number in place of the removed digits for each priority Value Range Max 32 digits...

Страница 882: ...r the PBX code of other PBXs in the TIE line network Value Range Max 3 digits consisting of 0 9 and Maintenance Console Location 11 1 9 1 TIE Table Programming Manual References None Feature Guide Ref...

Страница 883: ...Maintenance Console Location 11 1 9 1 TIE Table Programming Manual References None Feature Guide References 1 30 5 QSIG Enhanced Features PC Programming Manual 883 11 1 9 1 TIE Table...

Страница 884: ...Network ID to two PBXs will cause network data transmission problems Changing this value in Interactive mode will automatically clear any NDSS Link Data Value Range 0 The PBX retransmits BLF data sen...

Страница 885: ...1 Network Direct Station Selection NDSS Network Data Transmission for Centralised Operator Feature Data Transmission Counter Specifies the maximum number of hops or transmissions between two PBXs befo...

Страница 886: ...being cancelled Value Range 0 10 Maintenance Console Location 11 2 9 2 Network Data Transmission Programming Manual References 11 1 9 1 TIE Table Enhanced QSIG Call Information Activation Key Required...

Страница 887: ...Manual References 11 1 9 1 TIE Table Enhanced QSIG Call Information Activation Key Required Feature Guide References 1 30 5 2 Centralised Voice Mail PC Programming Manual 887 11 2 9 2 Network Data Tr...

Страница 888: ...tor PBX can be specified here Value Range Max 16 digits consisting of 0 9 and Maintenance Console Location 11 3 9 3 Network Operator VoIP Programming Manual References 11 2 9 2 Network Data Transmissi...

Страница 889: ...Programming Manual References 3 1 1 1 Slot Feature Guide References 1 30 5 1 Network Direct Station Selection NDSS PC Programming Manual 889 11 3 9 3 Network Operator VoIP...

Страница 890: ...extension attached to another PBX that will be monitored The number input here can use either Extension Number Method or PBX Code Method Value Range Max 16 digits consisting of 0 9 and Maintenance Con...

Страница 891: ...n is connected to reference only Value Range None 1 8 Maintenance Console Location 11 4 9 4 NDSS Key Table Programming Manual References 11 2 9 2 Network Data Transmission Network Data Transmission fo...

Страница 892: ...892 PC Programming Manual 11 4 9 4 NDSS Key Table...

Страница 893: ...Section 12 10 CO Incoming Call PC Programming Manual 893...

Страница 894: ...e shelf type and or position to which each trunk card belongs reference only Value Range For KX NCP500 KX NCP1000 KX TDE100 KX TDE200 Physical Virtual For KX TDE600 Shelf number Virtual Maintenance Co...

Страница 895: ...nnected reference only Value Range Card type Maintenance Console Location 12 1 10 1 CO Line Settings Programming Manual References None Feature Guide References None CO Name Specifies the trunk name w...

Страница 896: ...card is installed the value is automatically set to 7 for the corresponding trunks Value Range For KX NCP500 KX NCP1000 KX TDE100 KX TDE200 1 64 For KX TDE600 1 96 Maintenance Console Location 12 1 10...

Страница 897: ...ion is set different DIL destinations can be programmed depending on the time mode day lunch break night Generally DIL distribution is used for trunk calls from analogue trunks Tenant number and VM tr...

Страница 898: ...re Guide References None Card Type Indicates the trunk card type reference only Value Range Card type Maintenance Console Location 12 2 10 2 DIL Table Port Settings Programming Manual References None...

Страница 899: ...s on the trunk through which the calls arrive DDI DID Distribution depends on the DDI DID number of the calls MSN Distribution depends on the MSN of the calls Maintenance Console Location 12 2 10 2 DI...

Страница 900: ...erences 1 1 1 2 Direct In Line DIL 2 2 3 Tenant Service 2 2 4 Time Service VM Trunk Group No Specifies the number of the VM trunk group sent to the VPS when the DIL destination is the floating extensi...

Страница 901: ...type and or position reference only Value Range For KX NCP500 KX NCP1000 KX TDE100 KX TDE200 Physical Virtual For KX TDE600 Shelf number Virtual Maintenance Console Location 12 2 10 2 DIL Table Port S...

Страница 902: ...ntenance Console Location 12 2 10 2 DIL Table Port Settings Programming Manual References None Feature Guide References 1 1 1 1 Incoming Trunk Call Features SUMMARY Trunk Property Indicates the networ...

Страница 903: ...2 10 2 DIL Table Port Settings Programming Manual References None Feature Guide References 1 1 1 1 Incoming Trunk Call Features SUMMARY CLI Ring for DIL Day Lunch Break Night Enables CLI distribution...

Страница 904: ...ferences None Feature Guide References None Slot Indicates the slot position of each trunk card reference only Value Range Slot number Maintenance Console Location 12 2 10 2 DIL Table Port Settings Pr...

Страница 905: ...tworking type of each trunk reference only Value Range Public Private TIE VPN Maintenance Console Location 12 2 10 2 DIL Table Port Settings Programming Manual References None Feature Guide References...

Страница 906: ...git Specifies the number of leading digits to be removed from the incoming called number for DDI DID distribution or for TIE line service Value Range 0 15 Maintenance Console Location 12 2 10 2 DIL Ta...

Страница 907: ...gs Programming Manual References None Feature Guide References 1 1 1 3 Direct Inward Dialling DID Direct Dialling In DDI 1 1 1 4 Multiple Subscriber Number MSN Ringing Service 1 30 1 TIE Line Service...

Страница 908: ...1 6 Extension Number Setting It is possible to programme DDI DID numbers and DDI DID destinations in each time mode day lunch break night for a set of locations in series at once by clicking Automati...

Страница 909: ...Registration Feature Guide References 1 1 1 3 Direct Inward Dialling DID Direct Dialling In DDI 1 30 1 TIE Line Service Tenant Number Specifies the tenant number to determine the Time Table by which...

Страница 910: ...eferences None Feature Guide References 1 1 1 3 Direct Inward Dialling DID Direct Dialling In DDI 1 24 3 Voice Mail DPT Digital Integration CLI Ring for DDI DID Day Lunch Break Night Enables CLI distr...

Страница 911: ...ct Inward Dialling DID Direct Dialling In DDI Generate DDI DID Number From Specifies the DID number of the first location to be programmed DDI DID numbers for subsequent locations will be generated au...

Страница 912: ...or a certain time mode click the appropriate Same all check box If the Same all check box for a certain time mode is not clicked the destination numbers for subsequent locations will be generated auto...

Страница 913: ...s 12 3 10 3 DDI DID Table Feature Guide References 1 1 1 3 Direct Inward Dialling DID Direct Dialling In DDI Number to Generate Specifies the number of locations to be programmed Value Range 1 1000 Ma...

Страница 914: ...10 3 DDI DID Table Name Generate Programming Manual References 12 3 10 3 DDI DID Table Feature Guide References 1 1 1 3 Direct Inward Dialling DID Direct Dialling In DDI Name Suffix Specifies the tex...

Страница 915: ...rs Select the card to programme or select All to display all matching cards MSN To assign MSN destination numbers enter directly or click Destination Setting see 2 1 6 Extension Number Setting Shelf K...

Страница 916: ...d Maintenance Console Location 12 6 10 4 MSN Table Programming Manual References 3 33 1 1 Slot Port Property BRI Port Feature Guide References 1 1 1 4 Multiple Subscriber Number MSN Ringing Service MS...

Страница 917: ...mber Specifies the tenant number to determine the Time Table by which calls are distributed depending on the time of day Value Range For KX NCP500 KX NCP1000 KX TDE100 KX TDE200 1 8 For KX TDE600 1 32...

Страница 918: ...to the CLI destinations instead of the MSN destinations if the caller s identification number is found in the System Speed Dialling Table CLI distribution can be enabled or disabled for each time mod...

Страница 919: ...Table Programming Manual References None Feature Guide References None CLI Ring for MSN Day Lunch Break Night Enables CLI distribution in each time mode Value Range Disable Enable Maintenance Console...

Страница 920: ...nation Maintenance Console Location 12 7 10 5 Miscellaneous Programming Manual References None Feature Guide References 1 1 1 6 Intercept Routing 1 3 1 3 Do Not Disturb DND Intercept Routing to Operat...

Страница 921: ...ing feature to operate for extension calls Value Range Disable Enable Maintenance Console Location 12 7 10 5 Miscellaneous Programming Manual References None Feature Guide References 1 1 1 7 Intercept...

Страница 922: ...922 PC Programming Manual 12 7 10 5 Miscellaneous...

Страница 923: ...Section 13 11 Maintenance PC Programming Manual 923...

Страница 924: ...Manual References None Feature Guide References 1 26 1 1 Station Message Detail Recording SMDR SMDR Format Port Selects the Serial Interface port that is used to output the SMDR data Value Range None...

Страница 925: ...page The number of lines for the skip perforation should be shorter than the page length Value Range 0 95 Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Guide R...

Страница 926: ...dialled digits of outgoing trunk calls are printed Class of Service COS programming determines the printable records Value Range No Print Print Maintenance Console Location 13 1 11 1 Main Programming...

Страница 927: ...nt Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Guide References 1 26 1 1 Station Message Detail Recording SMDR Print Information Log in Log out Specifies whe...

Страница 928: ...Print Information Timed Reminder Wake up Call Selects whether Timed Reminder data is output on SMDR Value Range No Print Print Maintenance Console Location 13 1 11 1 Main Programming Manual Reference...

Страница 929: ...ion 13 1 11 1 Main Programming Manual References None Feature Guide References 1 5 4 8 Host PBX Access Code Access Code to the Telephone Company from a Host PBX 1 10 Automatic Route Selection ARS Feat...

Страница 930: ...t Print Dialled Number Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Guide References 1 6 1 1 Memory Dialling Features SUMMARY 1 26 1 1 Station Message Detail...

Страница 931: ...Value Range No Print Print Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Guide References 1 26 1 1 Station Message Detail Recording SMDR Option Condition Code...

Страница 932: ...re Guide References 1 26 1 1 Station Message Detail Recording SMDR LAN SMDR Port Number Specifies the port number used to output SMDR data via the LAN Value Range 1 65535 Maintenance Console Location...

Страница 933: ...e Guide References 1 26 1 1 Station Message Detail Recording SMDR RS 232C Communication Baud Rate Specifies the data transmission speed from the PBX to the printer or personal computer To ensure stabl...

Страница 934: ...cter Make an appropriate selection depending on the requirements of the printer or personal computer Value Range None Mark Space Even Odd Maintenance Console Location 13 1 11 1 Main Programming Manual...

Страница 935: ...ue Range None Hardware Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Guide References None Communication Stop Bit Selects a stop bit code that indicates the en...

Страница 936: ...ies the command to manually initialise an external modem The command specified here is controlled by PT system programming External Modem Control 801 Value Range Max 30 characters Maintenance Console...

Страница 937: ...eck of the PBX for local alarm and error log Value Range Disable Enable Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Guide References 2 4 3 Local Alarm Inform...

Страница 938: ...a Transmission for Centralised VM Feature Data Re transmission Repeat Counter in 11 2 9 2 Network Data Transmission Value Range Disable Enable Maintenance Console Location 13 1 11 1 Main Programming M...

Страница 939: ...e PBX to output local alarm information to a syslog server Value Range Disable Enable Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Guide References 1 26 1 2 S...

Страница 940: ...ut minor alarm information to a syslog server Value Range Disable Enable Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Guide References 1 26 1 2 Syslog Record...

Страница 941: ...this screen must be enabled Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Guide References 2 3 1 PC Programming Remo...

Страница 942: ...s the PBX from a remote location for maintenance purposes This number can be specified by Quick Setup Value Range Max 32 digits consisting of 0 9 and Maintenance Console Location 13 1 11 1 Main Progra...

Страница 943: ...e 4 10 digits consisting of 0 9 and Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Guide References 2 3 2 PT Programming Manager Password PT Programming Prog 1...

Страница 944: ...fies the system password used to access Maintenance Console at Administrator Level This password can only be set in Interactive mode Value Range 4 10 characters Maintenance Console Location 13 1 11 1...

Страница 945: ...Programming Manual References None Feature Guide References 2 3 1 PC Programming PC Programming Manual 945 13 1 11 1 Main...

Страница 946: ...erence only Value Range 000 999 Maintenance Console Location 13 2 11 2 PT Programming Access Programming Manual References None Feature Guide References 2 3 2 PT Programming PROG Selects whether User...

Страница 947: ...h to set connections from the Shelf list Note that PFT connections can only be made within the same shelf Trunk Card Slot No Specifies the position of the trunk card to be used Value Range For KX NCP5...

Страница 948: ...enance Console Location 13 3 11 3 Power Failure Transfer Programming Manual References None Feature Guide References 2 4 1 Power Failure Transfer 948 PC Programming Manual 13 3 11 3 Power Failure Tran...

Страница 949: ...ole Location 13 4 11 4 1 SNMP System Setting Programming Manual References None Feature Guide References 2 4 4 Simple Network Management Protocol SNMP System Monitor Port Number Receive Specifies the...

Страница 950: ...Location 13 4 11 4 1 SNMP System Setting Programming Manual References None Feature Guide References 2 4 4 Simple Network Management Protocol SNMP System Monitor MIB SysLocation Specifies a physical l...

Страница 951: ...Location 13 5 11 4 2 SNMP Manager Programming Manual References None Feature Guide References 2 4 4 Simple Network Management Protocol SNMP System Monitor Community Name Specifies a community name of...

Страница 952: ...ion 13 5 11 4 2 SNMP Manager Programming Manual References None Feature Guide References 2 4 4 Simple Network Management Protocol SNMP System Monitor TRAP Authentication Failure Selects whether the PB...

Страница 953: ...de References 2 4 4 Simple Network Management Protocol SNMP System Monitor TRAP Alarm Minor Selects whether the PBX sends Minor Alarm TRAP to an SNMP manager or not Value Range Disable Enable Maintena...

Страница 954: ...ow to select them for addition 4 Click OK Deleting CSs Follow the steps below to delete CSs from the air synchronisation group 1 Click Delete A dialogue box will appear Registered CSs are displayed on...

Страница 955: ...lot number Maintenance Console Location 13 6 11 5 Air Synchronisation Programming Manual References None Feature Guide References None Port Indicates the port number reference only Value Range Port nu...

Страница 956: ...desired cell in the column and then click Command Value Range INS The port is in service OUS The port is out of service Fault The port is not communicating with the network Maintenance Console Locatio...

Страница 957: ...Maintenance Console Location 13 6 11 5 Air Synchronisation Programming Manual References None Feature Guide References None Primary CS Index Specifies the number of the primary CS Value Range 1 32 Mai...

Страница 958: ...erence only Value Range Port number Maintenance Console Location 13 6 11 5 Air Synchronisation Programming Manual References None Feature Guide References None Primary CS CS Name Indicates the name of...

Страница 959: ...y CS Slot Indicates the slot position of the secondary CS reference only Value Range Slot number Maintenance Console Location 13 6 11 5 Air Synchronisation Programming Manual References None Feature G...

Страница 960: ...CS CS Name Indicates the name of the secondary CS reference only Value Range Max 20 characters Maintenance Console Location 13 6 11 5 Air Synchronisation Programming Manual References None Feature Gui...

Страница 961: ...Section 14 Appendix PC Programming Manual 961...

Страница 962: ...X TDE series OGM No BGM and Music on Hold Music Source of BGM2 7 for KX NCP series Music Source of BGM3 8 for KX TDE series Card 4 5 2 3 Timers Counters Miscellaneous Air Synchronisation Watching Dege...

Страница 963: ...ension First Digit Dial Extension Inter digit 6 1 4 1 1 Wired Extension Extension Settings Option 1 Wireless XDP 6 10 4 2 1 Portable Station Extension Settings Maximum length of extension number 8 6 6...

Страница 964: ...cards 3 4 1 1 Slot Card Property IPCMPR for KX NCP500 KX NCP1000 KX TDE100 KX TDE200 IPCEMPR for KX TDE600 VoIP DSP Option IP Extension Count of BGM 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW...

Страница 965: ...PDF Output 13 6 11 5 Air Synchronisation PC Programming Manual 965 14 1 2 KX NCP500 KX NCP1000 PBMPR Software File Version 4 1xxx...

Страница 966: ...t 3 9 1 1 Slot Shelf Property Virtual IP Gateway 3 58 1 1 Slot OPB3 Card Property 5 13 3 5 1 Incoming Call Distribution Group Group Settings 6 1 4 1 1 Wired Extension Extension Settings 6 9 4 1 7 Wire...

Страница 967: ...ation Key 3 4 1 1 Slot Card Property IPCMPR for KX NCP500 KX NCP1000 KX TDE100 KX TDE200 IPCEMPR for KX TDE600 3 15 1 1 Slot Port Property Virtual IP Extension 3 57 1 1 Slot Port Property IP Extension...

Страница 968: ...erator BGM BGM and Music on Hold Music Source of BGM2 7 for KX NCP series Music Source of BGM3 8 for KX TDE series OGM No BGM and Music on Hold Music Source of BGM2 7 for KX NCP series Music Source of...

Страница 969: ...2IP 3 14 1 1 Slot Card Property Virtual IP Extension 4 18 2 9 System Options Option 4 Send CLIP of CO Caller when call is transferred to CO CLIP of Held Party Send CLIP of CO Caller when call is forwa...

Страница 970: ...7 2 VM DPT Group Unit Settings Centralised VM Unit Setting Changed Contents 3 4 1 1 Slot Card Property IPCMPR for KX NCP500 KX NCP1000 KX TDE100 KX TDE200 IPCEMPR for KX TDE600 VoIP DSP Option IP Exte...

Страница 971: ...Hold Music Source of BGM2 7 for KX NCP series Music Source of BGM3 8 for KX TDE series OGM No BGM and Music on Hold Music Source of BGM2 7 for KX NCP series Music Source of BGM3 8 for KX TDE series C...

Страница 972: ...1 1 Slot Port Property IP Extension Port KX TDE series only 3 61 1 2 Portable Station 4 18 2 9 System Options Option 4 Send CLIP of CO Caller when call is transferred to CO CLIP of Held Party Send CL...

Страница 973: ...6 CTI CTI Hold Forced Idle when Hold by PDN SDN Key 5 20 3 7 2 VM DPT Group Unit Settings Centralised VM Unit Setting Changed Contents 3 4 1 1 Slot Card Property IPCMPR for KX NCP500 KX NCP1000 KX TDE...

Страница 974: ...974 PC Programming Manual 14 1 8 KX TDE600 PGMPR Software File Version 4 1xxx...

Страница 975: ...Feature Programming References PC Programming Manual 975...

Страница 976: ...CNIR CONR CF Rerouting CT CCBS AOC D AOC E E911 3PTY Feature Guide References 1 21 1 3 Advice of Charge AOC Automatic Callback Busy Camp on 4 9 2 6 1 Numbering Plan Main Features Automatic Callback Bu...

Страница 977: ...eature Guide References 1 17 4 Background Music BGM Budget Management 6 1 4 1 1 Wired Extension Extension Settings Option 3 Charge Limit 6 10 4 2 1 Portable Station Extension Settings Option 3 Charge...

Страница 978: ...end talk 5 6 3 1 5 Trunk Group Charge Rate 6 5 4 1 4 Wired Extension Flexible Button Type 6 13 4 2 3 Portable Station Flexible Button Type 6 17 4 3 DSS Console Type 8 2 6 2 Hotel Charge Charge Margin...

Страница 979: ...nager Group Forward Set Optional Device Other Extensions Remote Operation by Other Extension 5 1 3 1 1 Trunk Group TRG Settings Main CO CO Duration Time 60s Extension CO Duration Time 60s 5 13 3 5 1 I...

Страница 980: ...Recall 4 9 2 6 1 Numbering Plan Main Features Call Park Call Park Retrieve 6 5 4 1 4 Wired Extension Flexible Button Type Parameter Selection for Call Park Optional Parameter Ringing Tone Type Number...

Страница 981: ...Rerouting CT CCBS AOC D AOC E 3PTY 3 35 1 1 Slot Port Property PRI Port Supplementary Service COLP CLIR COLR CNIP CONP CNIR CONR CF Rerouting CT CCBS AOC D AOC E E911 3PTY Feature Guide References 1...

Страница 982: ...ngs Option 2 Manual C Waiting for Extension Call Option 2 Automatic C Waiting Option 4 Call Waiting Tone Type Feature Guide References 1 8 4 2 Call Waiting Tone Caller ID 4 5 2 3 Timers Counters Misce...

Страница 983: ...LP CLIR COLR CNIP CONP CNIR CONR CF Rerouting CT CCBS AOC D AOC E 3PTY 3 35 1 1 Slot Port Property PRI Port CO Setting Subscriber Number Supplementary Service COLP CLIR COLR CNIP CONP CNIR CONR CF Rer...

Страница 984: ...ces 1 30 4 2 Calling Connected Line Identification Presentation CLIP COLP and Calling Connected Name Identification Presentation CNIP CONP by QSIG Centralised Voice Mail 3 62 1 3 Option New Card Insta...

Страница 985: ...R CF Rerouting CT CCBS AOC D AOC E E911 3PTY CCBS Type CCBS Delete Digits Feature Guide References 1 21 1 10 Completion of Calls to Busy Subscriber CCBS Completion of Calls to Busy Subscriber CCBS by...

Страница 986: ...ence Group Member List Feature Guide References 1 15 1 Conference Group Call Confirmation Tone 4 18 2 9 System Options Option 3 Confirmation Tone Tone 1 Called by Voice Confirmation Tone Tone 2 Paged...

Страница 987: ...38 1 1 Slot Port Property T1 Port CO Dial Mode DTMF Width CO Pulse Speed 3 44 1 1 Slot Port Property E1 Port CO Dial Mode DTMF Width CO Pulse Speed 3 47 1 1 Slot Port Property EM Port KX TDE series on...

Страница 988: ...Counters Miscellaneous Extension PIN Lock Counter 4 12 2 7 1 Class of Service COS Settings Optional Device Other Extensions Accept the Call from DISA 5 1 3 1 1 Trunk Group TRG Settings Tone Detection...

Страница 989: ...References 1 3 1 3 Do Not Disturb DND Door Open 3 58 1 1 Slot OPB3 Card Property Device Type 4 5 2 3 Timers Counters DISA Door Reminder U Conf Doorphone Open Duration 4 9 2 6 1 Numbering Plan Main Fea...

Страница 990: ...al Lock Off Remote Extension Dial Lock On 4 12 2 7 1 Class of Service COS Settings TRS TRS Level on Extension Lock Feature Guide References 1 9 3 Extension Dial Lock Extension Feature Clear 4 9 2 6 1...

Страница 991: ...ellaneous TRS Check after EFA Feature Guide References 1 11 7 External Feature Access EFA External Relay Control 3 58 1 1 Slot OPB3 Card Property Device Type 4 9 2 6 1 Numbering Plan Main Features Ext...

Страница 992: ...20 2 Flexible Buttons Flexible Numbering Fixed Numbering 4 9 2 6 1 Numbering Plan Main Extension Features Other PBX Extension 4 10 2 6 2 Numbering Plan Quick Dial 4 11 2 6 3 Numbering Plan B NA DND Ca...

Страница 993: ...umber for Group Fwd Both Extension Number for Group Fwd External Extension Number for Group Fwd Internal 6 17 4 3 DSS Console Type Extension Number for Group Fwd Both Extension Number for Group Fwd Ex...

Страница 994: ...Reorder Tone for PT Hands free 6 1 4 1 1 Wired Extension Extension Settings Option 4 LCS Answer Mode Feature Guide References 1 11 1 Hands free Operation Headset Operation 3 24 1 1 Slot Port Property...

Страница 995: ...ng Call Distribution Group Features Incoming Call Log 5 13 3 5 1 Incoming Call Distribution Group Group Settings Miscellaneous Supervisor Extension Number 6 1 4 1 1 Wired Extension Extension Settings...

Страница 996: ...out Manual Queue Redirection Destination Day Lunch Break Night 6 1 4 1 1 Wired Extension Extension Settings Intercept Destination Intercept No Answer Time 6 10 4 2 1 Portable Station Extension Setting...

Страница 997: ...ion 3 15 1 1 Slot Port Property Virtual IP Extension 3 55 1 1 Slot Card Property IP Extension KX TDE series only 3 57 1 1 Slot Port Property IP Extension Port KX TDE series only Feature Guide Referenc...

Страница 998: ...tion 1 PT Fwd DND Fwd LED Option 1 PT Fwd DND DND LED Option 4 DSS Key DSS key mode for Incoming Call Feature Guide References 1 20 3 LED Indication Line Preference Incoming 6 1 4 1 1 Wired Extension...

Страница 999: ...d Extension Extension Settings Option 8 Wrap up Timer 6 5 4 1 4 Wired Extension Flexible Button Type Parameter Selection for Log in Log out Extension Number for Log in Log out 6 10 4 2 1 Portable Stat...

Страница 1000: ...Port Settings DDI DID TIE MSN Distribution Method DDI DID TIE MSN Remove Digit DDI DID TIE MSN Additional Dial 12 6 10 4 MSN Table Feature Guide References 1 1 1 4 Multiple Subscriber Number MSN Ringi...

Страница 1001: ...OHCA Whisper OHCA Feature Guide References 1 8 4 3 Off hook Call Announcement OHCA Off hook Monitor 4 18 2 9 System Options Option 1 PT Operation Off Hook Monitor for KX T74xx T75xx T76xx Feature Gui...

Страница 1002: ...ystem Options Option 4 Send CLIP of CO Caller when call is forwarded to CO Send CLIP of Extension Caller when call is forwarded to CO Feature Guide References 1 2 2 3 Outside Destinations in Incoming...

Страница 1003: ...rt Property T1 Port Pause Time 3 44 1 1 Slot Port Property E1 Port Pause Time 3 47 1 1 Slot Port Property EM Port KX TDE series only Pause Time 3 50 1 1 Slot Port Property DID Port KX TDE series only...

Страница 1004: ...erences 2 4 6 Packet Internet Groper PING Confirmation Portable Station PS Connection 3 61 1 2 Portable Station Feature Guide References 1 25 1 Portable Station PS Connection Power Failure Transfer 13...

Страница 1005: ...s Option 4 System Wireless Out of Range Registration Feature Guide References 1 30 6 1 PS Roaming by Network ICD Group PT Programming 4 12 2 7 1 Class of Service COS Settings Manager Programming Mode...

Страница 1006: ...n Feature Guide References 1 5 4 5 Reverse Circuit Ring Tone Pattern Selection 4 15 2 8 1 Ring Tone Patterns Call from CO Ring Tone Pattern Plan 1 8 4 16 2 8 2 Ring Tone Patterns Call from Doorphone R...

Страница 1007: ...Guide References 2 3 8 Software Upgrading Special Carrier Access Code 9 3 7 3 Special Carrier Feature Guide References 1 5 4 9 Special Carrier Access Code Speed Dialling Personal System 4 9 2 6 1 Num...

Страница 1008: ...2 4 Week Table 4 8 2 5 Holiday Table 4 14 2 7 3 Class of Service Internal Call Block 5 7 3 2 User Group 5 13 3 5 1 Incoming Call Distribution Group Group Settings Main Tenant Number 6 1 4 1 1 Wired E...

Страница 1009: ...TRS TRS Level Day Lunch Break Night 4 18 2 9 System Options Option 4 Private Network TIE Call by Extension Numbering Activation Key Required 5 1 3 1 1 Trunk Group TRG Settings Main COS 11 1 9 1 TIE T...

Страница 1010: ...tion 1 Timed Reminder Wake up Call 13 1 11 1 Main SMDR Print Information Timed Reminder Wake up Call Feature Guide References 1 28 4 Timed Reminder Toll Restriction TRS Call Barring Barring 4 12 2 7 1...

Страница 1011: ...r Selection for Single CO Parameter Selection for Group CO 6 13 4 2 3 Portable Station Flexible Button Type Parameter Selection for Single CO Parameter Selection for Group CO 6 17 4 3 DSS Console Type...

Страница 1012: ...ed Extension Extension Settings Option 1 ARS Itemised Code Option 3 Charge Limit 6 10 4 2 1 Portable Station Extension Settings Option 1 ARS Itemised Code Option 3 Charge Limit 8 3 6 3 Verification Co...

Страница 1013: ...ode 6 5 4 1 4 Wired Extension Flexible Button Type Extension Number for Two way Record Extension Number for Two way Transfer Extension Number for Voice Mail Transfer Ext No of Mailbox for Two way Tran...

Страница 1014: ...e Mail Transfer Feature Guide References 1 24 2 Voice Mail DTMF Integration Voice over Internet Protocol VoIP Network 3 56 1 1 Slot Card Property IP Extension Common Settings KX TDE series only Gatewa...

Страница 1015: ...ess XDP Parallel Mode 3 24 1 1 Slot Port Property Extension Port DPT Type Type 3 61 1 2 Portable Station PS Registration and De registration 4 9 2 6 1 Numbering Plan Main Features Wireless XDP Paralle...

Страница 1016: ...is copyrighted by Panasonic System Networks Co Ltd and may be reproduced for internal use only All other reproduction in whole or in part is prohibited without the written consent of Panasonic System...

Отзывы: