WHITE LEVEL ADJUSTMENT
1) Remove the CCD TOOL from CCD unit.
2) Attach the white paper on the CCD unit.
3) Attach the CCD TOOL on the CCD unit.
4) Adjust VR801 on the CCD board so that the waveform becomes 1.0
}
0.2V.
Notes:1. After the adjustment is finished, assemble the unit by reversing above procedure.
2. Please adjust with covering topside of the lens by hands in order not to let in outdoor daylight.
3. If you have no instrument to repair, trim off the chart on next page, then attach on the target glass.
(This is a temporary treatment. You should use an instrument for this adjustment purpose, if you require an
accurate repairment.)
5. DOCUMENT READ START POSITION ADJUSTMENT
1) Connect AC cord.
2) Copy the document, and confirm the read start position of the document.
3) If get out of position, adjust the read position.
4) Press the MENU button.
5) Press the #, 9, 0, 0, 0,
and 5, 6, 3 buttons.
6) Press the
,
, SET and MENU buttons.
30
.
.
.
16
15
14
.
.
.
00
To move the image to the right direction
Standard (Default)
To move the image to the left direction
The starting position of reading shifts 1 mm as number of changes.
CCD Tool
(PFZZ1F780M)
White Paper
(ex. PPC Paper)
WAVEFORM
1.0 0.2V
+
–
Chart
Содержание KX-F680BX
Страница 1: ......
Страница 11: ......
Страница 106: ......
Страница 107: ......
Страница 108: ......
Страница 109: ......
Страница 110: ......
Страница 111: ......
Страница 112: ......
Страница 113: ......
Страница 114: ......
Страница 115: ......
Страница 116: ......
Страница 117: ......
Страница 118: ......
Страница 119: ......
Страница 120: ......
Страница 121: ......
Страница 122: ......
Страница 123: ......
Страница 124: ......
Страница 125: ......
Страница 126: ......
Страница 127: ......
Страница 128: ......
Страница 129: ......
Страница 130: ... 165 KX F680BX KX F2681BX EC1 EC2 EC3 EC4 EC5 EC6 EC7 EC9 EC10 EC11 EC12 EC13 EC8 TOOLS ...
Страница 131: ......
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ......