Items
Procedure
Check or
Replace Parts
(
H
)*
Transmitted Power
Confirmation
Remove the Antenna before starting steps from 1 to 4.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
•
Test mode: FP
•
Traffic Channel: 5
•
Traffic Slot: 4
•
Mode: Loopback
•
PMID: 00000
2. Execute the command "testmode".
3. Initiate connection from DECT tester. (“set up connect”)
4. Confirm that the NTP value at ANT is 20dBm ~ 25dBm.
IC6,IC4,L2,
C57,C61,C75,
C77,C78,C76,
C68,C69,R79,
R80,C63,C64,
R83,R84,C65,
L3,C79,C67,
C66,D10,C62
(
I
)
Modulation Check and
Adjustment
Follow steps 1 to 3 of
(H)
above.
4. Confirm that the B-Field Modulation is 340kHz/div ~ 402kHz/div using data
type Fig31.
5. Adjust the B-Field Modulation if required. (Execute the command "readmod"
and "wrtmod xx", where xx is the value.)
IC6,IC4,L2,
C57,C61,C75,
C77,C78,C76,
C68,C69,R79,
R80,C63,C64,
R83,R84,C65,
L3,C79,C67,
C66,D10,C62
(
J
)
Frequency Offset
Confirmation
Follow steps 1 to 3 of
(H)
above.
4. Confirm that the frequency offset is -50KHz ~ +50kHz.
IC6,IC4,L2,
C57,C61,C75,
C77,C78,C76,
C68,C69,R79,
R80,C63,C64,
R83,R84,C65,
L3,C79,C67,
C66,D10,C62
(
K
)
Sensitivity Receiver
Confirmation
Follow steps 1 to 3 of
(H)
above.
4. Set DECT tester power to -88dBm.
5. Confirm that the BER is < 1000ppm.
IC6,IC4,L2,
C57,C61,C75,
C77,C78,C76,
C68,C69,R79,
R80,C63,C64,
R83,R84,C65,
L3,C79,C67,
C66,D10,C62
(
L
)
Timing Confirmation
Follow steps 1 to 3 of
(H)
above.
4. Confirm that the Timing accuracy is < ± 5.0ppm.
IC6,IC4,L2,
C57,C61,C75,
C77,C78,C76,
C68,C69,R79,
R80,C63,C64,
R83,R84,C65,
L3,C79,C67,
C66,D10,C62
(
M
)*
RSSI Level
Confirmation
Follow steps 1 to 3 of
(H)
above.
4. Set DECT tester power to -70dBm.
5. Execute the command "readrssi".
6. Confirm: 59
returned value
77 (0x68 ± F (hex))
IC6,IC4,L2,
C57,C61,C75,
C77,C78,C76,
C68,C69,R79,
R80,C63,C64,
R83,R84,C65,
L3,C79,C67,
C66,D10,C62
47
KX-TCD445BXS / KX-TCD445BXT / KX-TCD445BXF / KX-A144BXS / KX-A144BXT / KX-A144BXF /
Содержание KX-A144BXF
Страница 19: ...19 KX TCD445BXS KX TCD445BXT KX TCD445BXF KX A144BXS KX A144BXT KX A144BXF ...
Страница 26: ...8 6 Selecting a Base Unit 26 KX TCD445BXS KX TCD445BXT KX TCD445BXF KX A144BXS KX A144BXT KX A144BXF ...
Страница 29: ...29 KX TCD445BXS KX TCD445BXT KX TCD445BXF KX A144BXS KX A144BXT KX A144BXF ...
Страница 65: ...24 SIGNAL ROUTE 65 KX TCD445BXS KX TCD445BXT KX TCD445BXF KX A144BXS KX A144BXT KX A144BXF ...
Страница 83: ...33 2 KX A144BXS BXT BXF 83 KX TCD445BXS KX TCD445BXT KX TCD445BXF KX A144BXS KX A144BXT KX A144BXF ...