- 25 -
NR-BW415 / NR-BW465
13. TECHNICAL INFORMATION
NR-BW415VN, VW / NR-BW465VN, VW / NR-BW415XS / NR-BW465XS
•
Lead wire (Pink color) open
Recommend : At occurrence
1. Symptom of the problem
Effective from : Refer to page no. 28
Serial No. start : Refer to page no. 28
Countries
: Refer to page no. 28
Type
: Countermeasure taken
The defrost function didn’t operated caused by Lead wire open.
So the unit didn’t cool.
2. Cause
1. Some conductor of lead wire (Pink color) is breaking of wire by
2. When defrost function would operate, would start sparking
between conductors in condition of water condensation in
plastic bag.
3. Completely breaking of lead wire. (Pink color)
3. Detail of countermeasure / TI No. : REF 12-07
1) Change new lead wire (Pink) with new connector 1 pcs.
2) Connect by U-Connector 1 pcs.
3) Cover by silicone tape 1 pcs.
4) Replace new one plastic bag & cable tie per 1 pcs.
5) Refer to detail of KIT as below.
4. Description part addition / compatibility
Status
Ref.
Part Name
Description
Q’ty
Photos Content
New
1
Countermeasure kit
CNRBG17006KT
1 Kit
Lead wire (Pink color)
1 Pcs.
2
U-Connector
CNR76-316850
N/A
1 Pcs.
3
Silicone tape
CNR79-314920
1 Pcs.
4
Plastic bag
CNRAG-164170
1 Pcs.
5
Cable tie
CNR39-220010
1 Pcs.
Conditions
Countermeasure Kit to old unit
OK
Parts compatibility