Unlike many other appliances, the microwave oven is a high
voltage, high current device. It is free from danger in ordinary
use, though extreme care should be taken during repair.
Caution
Servicemen
should
remove
their
watches
whenever
working close to or replacing the magnetron.
3.1. Check the grounding
Do not operate on a two wire extension cord. The microwave
oven is designed to be grounded when used. It is imperative,
therefore, to ensure the appliance is properly grounded before
beginning repair work.
3.2. Inverter warnings
DANGER,
HIGH
VOLTAGE
AND
HIGHTEMPERATURE
(HOT/LIVE) OF THE INVERTERPOWER SUPPLY (U)
The High Voltage Inverter Power Supply handles very high
voltage and current for the magnetron tube. Though it is
free from danger in ordinary use, extreme care should be
taken during repair.
The aluminum heat sink is also energized with high voltage
(HOT), do not touch when the AC input terminals are
energized. The power device Collector is directly connected
to the aluminum heat sink.
The aluminum heat sink may be HOT due to heat energy,
therefore, extreme care should be taken during servicing.
H.V. Inverter warning
WARNING
FOR
INVERTER
POWER
SUPPLY
(U)
GROUNDING
Check the High Voltage Inverter Power Supply circuit
grounding. The high voltage inverter power supply circuit
board must have a proper chassis ground. The inverter
grounding bracket must be connected to the chassis. If the
inverter board is not grounded it will expose the user to very
high voltages and cause extreme DANGER! Be sure that
the inverter circuit is properly grounded via the inverter
grounding bracket.
Grounding of the inverter circuit board
WARNING!
DISCHARGE
THE
HIGH
VOLATGE
CAPACITORS
For about 30 seconds after the oven is turned off, an
electric charge remains in the high voltage capacitors in the
Inverter Power Supply circuit board.
When replacing or checking parts, remove the power plug
from the outlet and short the inverter output terminal of the
magnetron filament terminals to the chassis ground with an
insulated handle screwdriver to discharge. Please be sure
to touch the chassis ground side first and then short to the
output terminals.
3 CAUTIONS TO BE OBSERVED WHEN
TROUBLESHOOTING
10
NN-T695 NN-T685SF
Содержание INVERTER NN-H665
Страница 2: ...2 NN T695 NN T685SF ...
Страница 3: ...3 NN T695 NN T685SF ...
Страница 5: ...1 SCHEMATIC DIAGRAM 1 1 APH 5 NN T695 NN T685SF ...
Страница 6: ...1 2 CPH 6 NN T695 NN T685SF ...
Страница 7: ...1 3 RPH 7 NN T695 NN T685SF ...
Страница 24: ...9 EXPLODED VIEW AND PARTS LIST 9 1 EXPLODED VIEW 24 NN T695 NN T685SF ...
Страница 35: ...10 DIGITAL PROGRAMMER CIRCUIT 10 1 NN T695SF APH CPH T695SF SM RPH 35 NN T695 NN T685SF ...
Страница 36: ...36 NN T695 NN T685SF ...
Страница 37: ...10 2 NN T685SF APH CPH T675SF APH 37 NN T695 NN T685SF ...
Страница 38: ...38 NN T695 NN T685SF ...
Страница 39: ...10 3 NN T665SF APH T655SF APH T664SFR APH 39 NN T695 NN T685SF ...
Страница 40: ...40 NN T695 NN T685SF ...
Страница 41: ...10 4 NN H665 APH CPH H635 APH S655 APH S645 APH S615 CPH 41 NN T695 NN T685SF ...
Страница 42: ...42 NN T695 NN T685SF ...
Страница 44: ...44 NN T695 NN T685SF ...