![Panasonic IMAGECHECKER PV230 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/panasonic/imagechecker-pv230/imagechecker-pv230_manual_271802008.webp)
vi
├
Edge Threshold
─
0.01 to 1.00
├
Angle Range
─
2 to 20
└
Composite Code
─
None /
CC-A/B
(Selectable
only for GS1
DataBar)
For Data Matrix
├
Code Model
Parameter
┬
│
Standard / Enhanced / Manual
│
(Following items can be set when selecting "Manual".)
├
Training
└
Base Data on
─
Current Val. / Default Val.
├
Mirrored
─
No / Yes / Auto
├
Contrast Min.
─
1 to 100
├
Strict Model
─
No / Yes
├
Module Columns Min.
─
10 to 144
├
Module Columns Max.
─
10 to 144
├
Module Rows Min.
─
8 to 144
├
Module Rows Max.
─
8 to 144
├
Gap Size Min.
─
No / Small / Big
├
Gap Size Max.
─
No / Small / Big
├
Module Grid
─
Fixed / Variable / Auto
└
Slant Max.
─
0.0 to 30.0