14
Rack Mounting
Remove the
rubber feet.
z
Remove the rubber feet (4 pcs.) on the bottom of the
unit.
x
Install the rack mounting brackets (Option: Refer to the
following.) on both sides of the unit. Using the mounting
screws (4 pcs.) for the rack mounting brackets, fix them
firmly.
1. When installing one unit:
Model No.: WV-Q204/1S
• Rack mounting bracket (Large) x 1
• Rack mounting bracket (Small) x 1
• Rack mounting screws (M3 x 8: 6 pcs.)
2. When installing two units:
Model No.: WV-Q204/2S
• Rack mounting bracket (Small) x 2
• Joint bracket x 3
• Bracket mounting screws (M3 x 8: 6 pcs.)
• Bracket mounting screws
(Flat head, M3 x 8: 12 pcs.)
c
Install the unit in the rack.
• Using the rack mounting screws, fix them firmly.
Important:
• When operating the units, keep the temperature inside
the rack surely below 45 °C {113 °F}.
• Mount the unit into the rack with a space equivalent to
approx. 1 unit (44 mm) or more to separate from other
devices.
• To prevent the unit from overheating, do not block the
ventilation openings or slots in the cover.
• Be sure to keep the temperature inside the rack below
30 °C {86 °F} when operating the units. Installing venti-
lation fan(s) in the rack is recommended especially
when the rack is covered with front lids.
Rack mounting bracket (Small)
Rack mounting bracket (Large)
Bracket mounting
screws
(Remove two screws at the rear side,
and fix the brackets with bracket
mounting screws (Flat head, M3 x 6).
Joint bracket
Flat head screws
Flat head screws
Rack mounting
bracket (Small)
Rack mounting
bracket (Large)
Bracket mounting
screws
Rack mounting screws