Panasonic HYBRID IP-PBX KX-TDA100 Скачать руководство пользователя страница 1

Thank you for purchasing the Panasonic Hybrid IP-PBX, KX-TDA30/KX-TDA100/KX-TDA200.
Please read this manual carefully before using this product and save this manual for future use.

KX-TDA30/KX-TDA100/KX-TDA200: Version 1.1

 Model    

KX-TDA30/KX-TDA100/KX-TDA200

Hybrid IP-PBX

Installation Manual

SD Logo is
a trademark.

Содержание HYBRID IP-PBX KX-TDA100

Страница 1: ...X TDA30 KX TDA100 KX TDA200 Please read this manual carefully before using this product and save this manual for future use KX TDA30 KX TDA100 KX TDA200 Version 1 1 Model KX TDA30 KX TDA100 KX TDA200 Hybrid IP PBX Installation Manual SD Logo is a trademark ...

Страница 2: ... TDA0189 8 Port Caller ID Pay Tone Card CID PAY8 KX TDA0193 8 Port Caller ID Card CID8 KX TDA0284 4 Port BRI Card BRI4 KX TDA0288 8 Port BRI Card BRI8 KX TDA0290CE CJ PRI Card PRI30 KX TDA0290 PRI Card PRI23 KX TDA0480 4 Channel VoIP Gateway Card IP GW4 KX TDA0484 4 Channel VoIP Gateway Card IP GW4E Extension Cards KX TDA0143 4 Cell Station Interface Card CSIF4 KX TDA0144 8 Cell Station Interface ...

Страница 3: ... a DHLC DLC Card PT interface CS for 2 4 GHz Portable Station KX TDA0142CE 4 Channel Cell Station Unit Using a CSIF Card for DECT Portable Station KX TDA0142 3 Channel Cell Station Unit Using a CSIF Card for 2 4 GHz Portable Station Proprietary Equipment KX A228 S M type Back up Battery Cable KX A229 L type Back up Battery Cable KX A258 Blank Slot Cover KX T30865 Doorphone System Components Table ...

Страница 4: ...rd DLC4 KX TDA3172 8 Port Digital Extension Card DLC8 KX TDA3173 4 Port Single Line Telephone Extension Card SLC4 KX TDA3174 8 Port Single Line Telephone Extension Card SLC8 Other Cards KX TDA3105 Memory Expansion Card MEC KX TDA3161 4 Port Doorphone Card DPH4 KX TDA3162 2 Port Doorphone Card German Type DPH2 KX TDA3166 8 Channel Echo Canceller Card ECHO8 KX TDA3168 Extension Caller ID Card EXT CI...

Страница 5: ...e line telephone SLT Notice There are some optional service cards and features that are not available for certain countries areas Consult your certified Panasonic dealer for detailed instructions The power supply capacity of the Hybrid IP PBX may differ from the values described in this manual depending on the model number Please consult your dealer for detailed information The KX TDA100CN and KX ...

Страница 6: ...ll only fit into an earthing type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the earthing type plug 9 Do not allow anything to rest on the power cord Do not locate this product where the cord will be abused by people walking on it 10 Do not overload wall outl...

Страница 7: ...hange in performance 14 Avoid using a telephone other than a cordless type during an electrical storm There may be a remote risk of electric shock from lightning 15 Do not use the telephone to report a gas leak in the vicinity of the leak SAVE THESE INSTRUCTIONS ...

Страница 8: ...on For users in New Zealand only This equipment shall not be set to make automatic calls to the Telecom 111 Emergency Service The grant of a Telepermit for any item of terminal equipment indicates only that Telecom has accepted that the item complies with minimum conditions for connection to its network It indicates no endorsement of the product by Telecom nor does it provide any sort of warranty ...

Страница 9: ...E RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE THE POWER SUPPLY CORD IS USED AS THE MAIN DISCONNECT DEVICE ENSURE THAT THE SOCKET OUTLET IS LOCATED INSTALLED NEAR THE EQUIPMENT AND IS EASILY ACCESSIBLE CAUTION DANGER OF EXPLOSION EXISTS IF THE BATTERY IS INCORRECTLY REPLACED REPLACE THE BATTERY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE BATTERY MANUFACTURE...

Страница 10: ...o interwork with the Analogue Public Switched Telephone Network PSTN of a European country Pan European Integrated Services Digital Network ISDN using ISDN basic rate access Pan European Integrated Services Digital Network ISDN using ISDN primary rate access ONP 2048 kbit s digital structured leased lines D2048S We Panasonic Communications Co Ltd Panasonic Communications Company U K Ltd declare th...

Страница 11: ...nformation of the KX TDA Maintenance Console Section 4 Troubleshooting KX TDA100 KX TDA200 Provides information on the KX TDA100 KX TDA200 and telephone troubleshooting Section 5 System Outline KX TDA30 Provides general information on the KX TDA30 including the system capacity and specifications Section 6 Installation KX TDA30 Describes the procedures to install the KX TDA30 Detailed instructions ...

Страница 12: ...n the United States and or other countries Intel and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries All other trademarks identified herein are the property of their respective owners Screen shots reprinted with permission from Microsoft Corporation ...

Страница 13: ...MOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE CUT OFF PLUG IS INSERTED INTO ANY 13 AMP SOCKET If a new plug is to be fitted please observe the wiring code as shown below If in any doubt please consult a qualified electrician WARNING THIS APPLIANCE MUST BE EARTHED IMPORTANT The wires in this mains leads are coloured in accordance with the foll...

Страница 14: ...dress signalling The equipment must be connected to direct exchange lines and a payphone should not be connected as an extension 999 and 112 can be dialled on the apparatus after accessing the Exchange line for the purpose of making outgoing calls to the BT emergency 999 and 112 service During dialling this apparatus may tinkle the bells of other telephones using the same line This is not a fault ...

Страница 15: ...cations 39 2 2 3 Opening Closing the Front Cover 40 2 2 4 Installing Replacing the Power Supply Unit 42 2 2 5 Frame Earth Connection 46 2 2 6 Backup Batteries Connection 47 2 2 7 Installing Removing the Optional Service Cards 48 2 2 8 Types of Connectors 53 2 2 9 Attaching a Ferrite Core 55 2 2 10 Fastening Amphenol Type Connector 57 2 2 11 Wall Mounting KX TDA200 59 2 2 12 Wall Mounting KX TDA100...

Страница 16: ...ble Stations KX TDA100 KX TDA200 136 2 8 1 Overview 136 2 8 2 Procedure Overview 138 2 8 3 Site Planning 140 2 8 4 Before Site Survey 144 2 8 5 Site Survey Using the KX TCA255 KX TD7590 148 2 8 6 After Site Survey 152 2 8 7 Connecting a Cell Station to the Hybrid IP PBX 153 2 8 8 Wall Mounting 162 2 9 Connection of 2 4 GHz Portable Stations KX TDA100 KX TDA200 164 2 9 1 Overview 164 2 9 2 Procedur...

Страница 17: ...DA30 5 System Outline KX TDA30 235 5 1 System Highlights KX TDA30 236 5 1 1 System Highlights 236 5 2 Basic System Construction KX TDA30 238 5 2 1 Main Unit 238 5 2 2 System Connection Diagram 239 5 3 Options KX TDA30 241 5 3 1 Options 241 5 4 Specifications KX TDA30 243 5 4 1 General Description 243 5 4 2 Characteristics 245 5 4 3 System Capacity 246 6 Installation KX TDA30 249 6 1 Before Install...

Страница 18: ...XDP Connection 316 6 6 4 First Party Call Control CTI Connection 321 6 7 Connection of DECT Portable Stations KX TDA30 322 6 7 1 Overview 322 6 7 2 Procedure Overview 324 6 7 3 Site Planning 326 6 7 4 Before Site Survey 330 6 7 5 Site Survey Using the KX TCA255 KX TD7590 334 6 7 6 After Site Survey 338 6 7 7 Connecting a Cell Station to the Hybrid IP PBX 339 6 7 8 Wall Mounting 346 6 8 Connection ...

Страница 19: ...3 Installation of the KX TDA30 Maintenance Console 395 7 3 1 Installing and Starting the KX TDA30 Maintenance Console 395 7 3 2 Structure of the KX TDA30 Maintenance Console 399 7 3 3 Hybrid IP PBX Configuration 400 7 3 4 Hybrid IP PBX Maintenance 401 8 Troubleshooting KX TDA30 403 8 1 Troubleshooting KX TDA30 404 8 1 1 Installation 404 8 1 2 Connection 405 8 1 3 Operation 407 8 1 4 Using the Rese...

Страница 20: ...20 Installation Manual ...

Страница 21: ...Installation Manual 21 Section 1 System Outline KX TDA100 KX TDA200 This section provides general information on the Hybrid IP PBX including the system capacity and specifications ...

Страница 22: ...euing Feature When a preprogrammed number of extensions in an incoming call distribution group are busy additional incoming calls can wait in a queue While calls are waiting in the queue the calls are handled by the Queuing Time Table which can be assigned for each time mode day lunch break night Log in Log out Incoming call distribution group members can join Log in or leave Log out the groups ma...

Страница 23: ... each telephone to act as an independent extension with its own extension number Digital XDP A DPT can be connected to another DPT which is connected to a DPT port or a Super Hybrid Port of the PBX Similar to XDP mode each DPT acts as an independent extension with its own extension number Portable Station PS Features PSs e g KX TD7690 can be connected to this Hybrid IP PBX It is possible to use th...

Страница 24: ...ystem Construction KX TDA100 KX TDA200 1 2 1 Basic Shelf The basic shelf contains an MPR card For system expansion optional service cards and a power supply unit can be installed in the basic shelf Construction of Basic Shelf KX TDA100 KX TDA200 B B A A A Slots for Expansion B MPR Card ...

Страница 25: ...Hold MOH Pager Speaker Batteries Voice Processing System KX T7636 KX T7633 Remote PC PC Printer Router Private IP Network Trunk Telephone Company Lines Analogue BRI PRI T1 E1 Hybrid IP PBX PC SLT CS PS Wireless Phone Fax Machine PC USB APT DPT ISDN Telephone Amplifier Server PC PC PC SLT DPT DSS Console DSS Console KX T7600 DPT KX T7600 DPT ...

Страница 26: ... KX TDA0183 DLC16 KX TDA0172 DLC8 KX TDA0171 DHLC8 KX TDA0170 MSLC16 KX TDA0175 SLC16 KX TDA0174 SLC8 KX TDA0173 CSIF4 KX TDA0143 CSIF8 KX TDA0144 CTI LINK KX TDA0410 OPB3 KX TDA0190 E1 KX TDA0188 IP GW4 KX TDA0480 IP GW4E KX TDA0484 PRI30 KX TDA0290 CE CJ PRI23 KX TDA0290 BRI4 KX TDA0284 BRI8 KX TDA0288 T1 KX TDA0187 E M8 KX TDA0184 DID8 KX TDA0182 Analogue Analogue Trunk Trunk Analogue Trunk E M...

Страница 27: ...r 2 German type doorphones and 2 door openers To be mounted on the OPB3 card 4 8 KX TDA0166 16 Channel Echo Canceller Card ECHO16 16 channel card for echo cancellation during conferences To be mounted on the OPB3 card 2 2 KX TDA0170 8 Port Digital Hybrid Extension Card DHLC8 8 port digital hybrid extension card for DPTs APTs SLTs DSS consoles and PT interface CSs with 2 power failure transfer PFT ...

Страница 28: ...4 KX TDA0188 E 1 Trunk Card E1 1 port E1 trunk card ITU T standard compliant 2 4 KX TDA0189 8 Port Caller ID Pay Tone Card CID PAY8 8 port Caller ID signal type FSK FSK with Call Waiting Caller ID Visual Caller ID DTMF and 8 ports of Pay Tone Service 12 kHz 16 kHz To be mounted on the LCOT8 LCOT16 cards 8 16 KX TDA0190 Optional 3 Slot Base Card OPB3 Optional 3 slot base card for mounting a maximum...

Страница 29: ...e 1 1 KX TDA0480 4 Channel VoIP Gateway Card IP GW4 4 channel VoIP gateway card VoIP H 323 V 2 ITU T G 729a and G 723 1 compliant G3 fax support 2 4 KX TDA0484 4 Channel VoIP Gateway Card IP GW4E 4 channel VoIP gateway card VoIP H 323 V 2 ITU T G 729a G 723 1 and G 711 compliant 2 4 KX TDA0103 L Type Power Supply Unit PSU L Power Supply Unit for KX TDA200 Total power output of 279 W Safety Class 1...

Страница 30: ...imum Power Failure Tolerance 300 ms without using backup batteries Memory Backup Duration 7 years Dialling Trunk Dial Pulse DP 10 pps 20 pps Tone DTMF Dialling Extension Dial Pulse DP 10 pps 20 pps Tone DTMF Dialling Mode Conversion DP DTMF DTMF DP Ring Frequency 20 Hz 25 Hz selectable Trunk Loop Limit 1600 maximum Operating Environment Temperature 0 C to 40 C Humidity 10 to 90 non condensing Conf...

Страница 31: ...PT 1 pair wire D1 D2 or 2 pair wire T R D1 D2 APT 2 pair wire T R D1 D2 PT interface CS 1 pair wire D1 D2 DSS Console and Add on Key Module 1 pair wire D1 D2 Dimension KX TDA100 334 mm W 390 mm H 270 mm D KX TDA200 430 mm W 415 mm H 270 mm D Weight when fully mounted KX TDA100 Under 12 kg KX TDA200 Under 16 kg ...

Страница 32: ...Port connection of a PT and an SLT 3 by Digital eXtra Device Port connection of two DPTs and an SLT Ring Voltage 75 Vrms at 20 Hz 25 Hz depending on the Ringing Load Trunk Loop Limit 1600 maximum Hookswitch Flash Recall Timing Range 24 ms to 2032 ms BRI Cards Internal ISDN Mode Supply Voltage 40 V Power Supply 4 5 W per 1 line 10 W per 4 lines BRI4 4 5 W per 1 line 20 W per 8 lines BRI8 Power Supp...

Страница 33: ...ed Maximum Terminal Equipment The following number of terminal equipment can be supported by the Hybrid IP PBX Card Type KX TDA100 KX TDA200 Trunk Card 1 1 One T1 E1 PRI30 PRI23 or IP GW4 card counts as 2 cards 4 8 Extension Card 4 8 Total 5 10 Terminal Equipment Type KX TDA100 KX TDA200 Without an MEC Card With an MEC Card Without an MEC Card With an MEC Card Telephone 1 1 A single T1 OPX Off Pre...

Страница 34: ...re Calculation PSU Capability Each PSU supports a different amount of load figures Equipment Type Load Figure PT KX T7600 series DPT DSS console and KX T7560 KX T7565 DPT 1 APT and other DPT DSS console 4 Extension Card 1 1 Only the extension cards that can support SLTs count for the load figures DHLC8 8 SLC8 8 SLC16 16 MSLC16 16 CS 4 ISDN Extension 2 VPS 1 PSU Type Maximum Load Figures PSU S 1 1 ...

Страница 35: ... the procedures to install the Hybrid IP PBX Detailed instructions for planning the installation site installing the shelves and optional service cards and cabling of peripheral equipment are provided Further information on system expansion and peripheral equipment installation is included ...

Страница 36: ...ay result in malfunction noise or discolouration 1 In direct sunlight and hot cold or humid places Temperature range 0 C to 40 C 2 Sulphuric gases produced in areas where there are thermal springs etc may damage the equipment or contacts 3 Places in which shocks or vibrations are frequent or strong 4 Dusty places or places where water or oil may come into contact with the unit 5 Near high frequenc...

Страница 37: ...s 5 The power switch and battery switch of the Hybrid IP PBX must be off during wiring After the wiring is completed turn the power switch on 6 Mis wiring may cause the Hybrid IP PBX to operate improperly 7 If an extension does not operate properly disconnect the telephone from the extension line and then connect again or turn the power to the Hybrid IP PBX off and on again 8 The Hybrid IP PBX is ...

Страница 38: ...DA100 KX TDA200 2 2 1 Unpacking Unpack the box and check the items below KX TDA100 KX TDA200 Main Unit 1 1 AC Cord with a Ferrite Core 1 1 In Canada there is no ferrite core attached to the AC cord 1 1 Metal Bracket 1 1 Screw A 3 4 Screw B Black 2 6 Anchor Plug 3 4 Mini Plug for pager and music source 4 4 SD Memory Card 1 1 ...

Страница 39: ...iew Note Null slot is not available for any optional service card MPR Card Slot RUN Indicator ALARM Indicator RS 232C Port Free Slots 1 to 5 Free Slots 1 to 10 USB Port RS 232C Port USB Port RUN Indicator ALARM Indicator MPR Card Slot Null Slot PSU Slot PSU Slot Option Card Slot Option Card Slot KX TDA100 KX TDA200 ...

Страница 40: ...ning Closing the Front Cover Opening the Front Cover 1 Insert a flathead screwdriver into the opening on the left of the screw cover and unlatch the screw cover 2 Turn the screw anticlockwise to loosen 3 Slide the front cover to the right until it stops then lift the front cover Screw Cover ...

Страница 41: ... protrusions on the cover with the receptacles on the cabinet Then slide the front cover to the left until it locks 2 Turn the screw clockwise to tighten 3 Secure the screw cover Notes For safety reasons close the front cover and tighten the screw when the Hybrid IP PBX is in operation Do not forget to tighten the screw before securing the screw cover 1 2 ...

Страница 42: ...e mains outlet ground and the PSU case To ensure the PBX chassis is safely grounded it is essential that the PSU case be securely fastened to the PBX chassis with the 4 screws provided with each PSU When installing or replacing PSU basic safety precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following PSU Type Lower Upper Input Vo...

Страница 43: ... battery supply are disconnected 4 To protect the back board from static electricity do not touch parts on the back board in the main unit and PSU To discharge static electricity touch ground or wear an earthing strap The following procedures are for installing or replacing a PSU only Do not replace or remove the PSU for any other purpose Installing the Power Supply Unit 1 Insert the PSU along the...

Страница 44: ...the direction of the arrow so that the PSU engages securely with the connector on the back board 3 Turn the 4 screws clockwise in the order indicated by the numbers 1 to 4 to fix the PSU Replacing the Power Supply Unit 1 Unplug the AC power cord and Back up Battery Cable Release Lever Back Board Screws 1 3 2 4 ...

Страница 45: ...al 45 2 Turn the 4 screws anticlockwise to loosen them 3 Pull the release lever in the direction of the arrow to disconnect the PSU from the back board 4 Replace the PSU 5 Follow the steps in Installing the Power Supply Unit Screws Release Lever Back Board Current PSU New PSU ...

Страница 46: ...the user of electrocution in the case of lightning strike The earthing wire of the AC cable has an effect against the external noise and lightning strikes but it may not be enough to protect the Hybrid IP PBX A permanent connection between earth and the earth terminal of the Hybrid IP PBX must be made 1 Loosen the screw 2 Insert an earthing wire user supplied 3 Tighten the screw 4 Connect the eart...

Страница 47: ...t be maintained Make sure that the type and capacity of the 3 backup batteries are identical The Back up Battery Cable should not be exposed to direct sunlight Keep the Back up Battery Cable and the backup batteries away from heating appliances and fire Place the backup batteries in ventilated place For details about the backup batteries refer to the manual intended for the batteries CAUTION Be su...

Страница 48: ...tricity touch ground or wear an earthing strap Note The optional service cards can be installed or removed while the DC power is supplied However when installing or removing the MPR card the DC power supply must be turned off Installing Optional Service Cards 1 Insert the card along the guide rails Card Type Slot Type KX TDA100 Free Slots 1 to 5 KX TDA200 Free Slots 1 to 10 Option Slot MPR Slot MP...

Страница 49: ...card as shown below push the release lever in the direction of the arrow so that the card engages securely with the connector on the back board 3 Turn the 2 screws clockwise to fix the card in place Note Make sure the screws are tightened to earth the card securely Release Lever Back Board Screws ...

Страница 50: ... KX TDA200 50 Installation Manual Covering the Blank Slots Be sure to cover each slot in which no optional service card is installed by using a Blank Slot Cover CAUTION Failure to install the Blank Slot Cover may cause electromagnetic interferences ...

Страница 51: ...llation Manual 51 Handling of the Cables When cables are connected to the Hybrid IP PBX run the cables to either right or left and then towards the backside of the cabinet as shown below Note For safety reasons do not stretch bend or pinch the AC power cord 3 4 1 2 ...

Страница 52: ...tion Manual Removing the Optional Service Cards 1 Turn the 2 screws anticlockwise to loosen them 2 Pull the release lever in the direction of the arrow to disconnect the card from the back board Pull the card from the cabinet to remove it Screws Release Lever Back Board ...

Страница 53: ...e CSIF4 KX TDA0143 CSIF8 KX TDA0144 T1 KX TDA0187 E1 KX TDA0188 BRI4 KX TDA0284 BRI8 KX TDA0288 PRI30 KX TDA0290CE CJ PRI23 KX TDA0290 CTI LINK KX TDA0410 IP GW4 KX TDA0480 IP GW4E KX TDA0484 E1 KX TDA0188 PRI30 KX TDA0290CE CJ Shielded twisted pair cable DHLC8 KX TDA0170 DLC8 KX TDA0171 DLC16 KX TDA0172 SLC8 KX TDA0173 SLC16 KX TDA0174 MSLC16 KX TDA0175 LCOT8 KX TDA0180 LCOT16 KX TDA0181 DID8 KX ...

Страница 54: ...X TDA100 KX TDA200 54 Installation Manual DPH4 KX TDA0161 DPH2 KX TDA0162 IP GW4 KX TDA0480 Basic Shelf MPR MPR Connector Type Pin Number Used for 10 pin Terminal Block 8 pin Terminal Block 8 1 10 1 RS 232C 9 5 6 1 USB 2 1 3 4 Mini Plug 2 4 ...

Страница 55: ...ore is included with the card When connecting a T1 E1 PRI card Wrap the cable once around the ferrite core then close the case of the ferrite core Attach the ferrite core 5 cm away from the connector When connecting a BRI card Attach the ferrite core then close the case of the ferrite core Attach the ferrite core as close to the card s connector as possible 5 cm When only 1 or 2 cables are used fo...

Страница 56: ...ore a ferrite core holds a maximum of 4 cables When connecting an extension card Pass the cable through the ferrite core then close the case of the ferrite core Attach the ferrite core 3 cm away from the connector If you need to open the ferrite core use a flathead screwdriver to unlatch the case of the ferrite core 3 cm ...

Страница 57: ...rvice cards To connect an Amphenol connector use the spring latch or screw to fix the upper part and use Velcro tape to fix the lower part of the connector Type A Spring Latch Velcro Tape Type B Screw Velcro Tape Velcro Tape Velcro Tape 2 1 2 2 1 Spring Latch 1 Spring Latch Remove the screw on the optional service card Insert the screw included with the Amphenol or optional service card ...

Страница 58: ...C 4 RD RD RD RD SGA RB D2D RD RD RB 29 TD TD TD TD SGB TB D1D TD TD TB 5 RE RE RE TB D2B D2B D2E RE RE 30 TE TE TE RB D1B D1B D1E TE TE 6 RF RF RF T1B D2F RF RF 31 TF TF TF R1B D1F TF TF 7 RG RG RG EB RC D2G RG RG RC 32 TG TG TG MB TC D1G TG TG TC 8 RH RH RH TC D2C D2C D2H RH RH 33 TH TH TH RC D1C D1C D1H TH TH 9 RI T1C D2I RI RI 34 TI R1C D1I TI TI 10 RJ EC RD D2J RJ RJ RD 35 TJ MC TD D1J TJ TJ T...

Страница 59: ...mounting screws into the wall Be careful to avoid touching any metal laths wire laths or metal plates in the wall 1 Install 4 anchor plugs in the wall using the metal bracket as a template Fix the metal bracket with 4 screws A Screw A Screw A Metal Bracket Hammer Anchor Plug 30 mm 6 5 mm Wall TOP TOP Anchor Plug Metal Bracket ...

Страница 60: ... screws B to fix both sides of the cabinet Notes Do not block the openings of the cabinet Allow space of at least 20 cm above and 10 cm at the sides of the cabinet Make sure that the wall behind the cabinet is flat and free of obstacles so that the openings on the back of the cabinet will not be blocked Make sure that the wall behind the cabinet is not made of wood Be careful not to drop the cabin...

Страница 61: ...mounting screws into the wall Be careful to avoid touching any metal laths wire laths or metal plates in the wall 1 Install 3 anchor plugs in the wall using the metal bracket as a template Fix the metal bracket with 3 screws A Metal Bracket Screw A Anchor Plug Wall TOP TOP Screw A Hammer Anchor Plug 30 mm 6 5 mm Metal Bracket ...

Страница 62: ... screws B to fix both sides of the cabinet Notes Do not block the openings of the cabinet Allow space of at least 20 cm above and 10 cm at the sides of the cabinet Make sure that the wall behind the cabinet is flat and free of obstacles so that the openings on the back of the cabinet will not be blocked Make sure that the wall behind the cabinet is not made of wood Be careful not to drop the cabin...

Страница 63: ...DA200 Only 1 Install 4 anchor plugs in the floor using the metal bracket as a template Fix the metal bracket with 4 screws A 2 Remove the front cover of the cabinet refer to 2 2 3 Opening Closing the Front Cover Anchor Plug Hammer 30 mm 6 5 mm Metal Bracket Screw A Floor Screw A Metal Bracket Anchor Plug TOP ...

Страница 64: ...ds until it locks and retain it with 2 screws B Notes Do not block the openings of the cabinet Allow space of at least 20 cm above and 10 cm at the sides of the cabinet Make sure that the surface behind the cabinet is flat and free of obstacles so that the openings on the back of the cabinet will not be blocked Screws B Metal Bracket FRONT TOP 1 2 ...

Страница 65: ...P PBX KX TDA100 KX TDA200 Installation Manual 65 Make sure that the surface behind the cabinet is not made of wood Be careful not to drop the cabinet 4 Fix the front cover on the cabinet refer to 2 2 3 Opening Closing the Front Cover ...

Страница 66: ...ons requiring the installation of lightning protection A lightning strike to a telephone cable which is 10 m above ground can be as high as 200 000 V The Hybrid IP PBX must be installed with lightning protectors In addition earthing connection to earth is very important for the protection of the user Be sure to comply with applicable local regulations e g law guidelines Recommended Lightning Prote...

Страница 67: ...t to protect the wire Note The lightning protector for an extension and CS is different from that for trunks Installation of an Earth Rod 1 Installation location of the earth rod Near the protector CS SLT PT Main Building Trunk Trunk Extn Extn Extn Extension Line Earth Another Building Extn Extn Lightning Protectors Terminal Board Lightning Protector SLT PT Hybrid IP PBX CS Trunk Hybrid IP PBX Ear...

Страница 68: ...obstructions None 3 Composition of the earth rod Metal 4 Depth of the earth rod More than 50 cm 5 Cross sectional area of the earthing wire More than 1 3 mm2 Notes The above figures are recommendations only The length of earth rod and the required depth depend on the composition of the soil ...

Страница 69: ...2 MEC Card and 2 3 3 RMT Card Notes For details about connecting peripherals refer to 2 11 1 Connection of Peripherals For details about System Initialise Switch refer to 2 13 1 Starting the Hybrid IP PBX For details about Reset Button refer to 4 1 4 Using the Reset Button CAUTION Use only the SD Memory Card included with the Hybrid IP PBX The SD Memory Card contains software for all the processes...

Страница 70: ...ration may cause damage to the SD Memory Card or result in loss of data A LITHIUM BATTERY IS USED IN THE MPR CARD THERE IS A RISK OF EXPLOSION IF BATTERY IS REPLACED WITH THE INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS LED Indications Indication Colour Description BATT ALARM Red Battery alarm indication OFF Normal ON Alarm SD ACCESS Green SD memory card status ON Accessi...

Страница 71: ... 71 2 3 2 MEC Card Function Memory expansion card for Broadcasting features and to double the number of DPTs using Digital XDP connection To be installed in the MEC slot Accessory and User supplied Items Accessory included Screws 2 User supplied not included none MEC Card Screw inside ...

Страница 72: ...Installation Manual 2 3 3 RMT Card Function Analogue modem card for remote communication with the Hybrid IP PBX V90 support To be mounted on the MPR card Accessory and User supplied Items Accessory included Screws 2 User supplied not included none RMT Card Screw inside ...

Страница 73: ...fer to 2 12 1 Power Failure Connections To confirm the trunk connection refer to Confirming the Trunk Connection in 2 13 1 Starting the Hybrid IP PBX LCOT4 4 port analogue trunk card with 2 power failure transfer PFT ports LCOT8 8 port analogue trunk card with 2 power failure transfer PFT ports One CID8 or CID PAY8 card can be mounted on the LCOT8 card refer to 2 4 3 CID PAY8 Card and 2 4 4 CID8 C...

Страница 74: ...TE Tip port 5 6 RF Ring port 6 31 TF Tip port 6 7 RG Ring port 7 32 TG Tip port 7 8 RH Ring port 8 33 TH Tip port 8 9 RI Ring port 9 34 TI Tip port 9 10 RJ Ring port 10 35 TJ Tip port 10 11 RK Ring port 11 36 TK Tip port 11 12 RL Ring port 12 37 TL Tip port 12 13 RM Ring port 13 38 TM Tip port 13 14 RN Ring port 14 39 TN Tip port 14 15 RO Ring port 15 40 TO Tip port 15 16 RP Ring port 16 41 TP Tip...

Страница 75: ...cessory and User supplied Items Accessory included Screws 2 User supplied not included Amphenol connector Notes To connect the Amphenol connector refer to 2 2 10 Fastening Amphenol Type Connector To confirm the trunk connection refer to Confirming the Trunk Connection in 2 13 1 Starting the Hybrid IP PBX To DID line LED Amphenol ...

Страница 76: ...port 3 4 RD Ring port 4 29 TD Tip port 4 5 RE Ring port 5 30 TE Tip port 5 6 RF Ring port 6 31 TF Tip port 6 7 RG Ring port 7 32 TG Tip port 7 8 RH Ring port 8 33 TH Tip port 8 9 25 Reserved 34 50 Reserved Indication Colour Description CARD STATUS Green Red Card status indication OFF Power Off Green ON Normal all ports are idle Green Flashing 60 times per minute Normal a port is in use Red ON Faul...

Страница 77: ...ems Accessory included Screws 2 User supplied not included none Note Only 1 CID PAY8 card can be mounted on the LCOT8 card Switch Settings on LCOT8 LCOT16 cards Switch Type Usage and Status Definition Port Setting DIP Set all DIP switches at OFF positions Note SW2 is for the LCOT16 card only CID PAY8 Card inside Screw Set all DIP switches for ports 01 08 at OFF positions Set all DIP switches for p...

Страница 78: ...ccessory and User supplied Items Accessory included Screws 2 User supplied not included none Note Only 1 CID8 card can be mounted on the LCOT8 card Switch Settings on LCOT8 LCOT16 cards Switch Type Usage and Status Definition Port Setting DIP Keep all DIP switches at default ON positions Do not change the positions of these switches Note SW2 is for the LCOT16 card only CID8 Card inside Screw OFF O...

Страница 79: ...ied not included Amphenol connector Notes Connect this optional service card to the trunk through terminal board from the E M TIE line do not connect to the trunk directly To connect the Amphenol connector refer to 2 2 10 Fastening Amphenol Type Connector To confirm the trunk connection refer to Confirming the Trunk Connection in 2 13 1 Starting the Hybrid IP PBX To terminal board from the E M TIE...

Страница 80: ...T1C Tip 1 port 3 34 R1C Ring 1 port 3 10 EC E line port 3 35 MC M line port 3 11 TD Tip port 4 36 RD Ring port 4 12 T1D Tip 1 port 4 37 R1D Ring 1 port 4 13 ED E line port 4 38 MD M line port 4 14 TE Tip port 5 39 RE Ring port 5 15 T1E Tip 1 port 5 40 R1E Ring 1 port 5 16 EE E line port 5 41 ME M line port 5 17 TF Tip port 6 42 RF Ring port 6 18 T1F Tip 1 port 6 43 R1F Ring 1 port 6 19 EF E line p...

Страница 81: ...81 LED Indications Indication Colour Description CARD STATUS Green Red Card status indication OFF Power Off Green ON Normal all ports are idle Green Flashing 60 times per minute Normal a port is in use Red ON Fault includes reset Red Flashing 60 times per minute Out of Service ...

Страница 82: ...included ferrite core except in Canada where the ferrite core is not necessarily required Refer to 2 2 9 Attaching a Ferrite Core This optional service card can be used for either trunk or extension connection by setting the A B switch or using the connector with appropriate pin assignments To confirm the trunk connection refer to Confirming the Trunk Connection in 2 13 1 Starting the Hybrid IP PB...

Страница 83: ...eserved 4 RX Receive data 5 RX Receive data 6 8 Reserved Indication Colour Description CARD STATUS Green Red Card status indication OFF Power Off Green ON Normal all ports are idle Green Flashing 60 times per minute Normal a port is in use Red ON Fault includes reset Red Flashing 60 times per minute Out of Service SYNC ERR Red Non synchronisation status indication OFF Normal ON Out of synchronisat...

Страница 84: ...sion Connection The maximum distance of the extension cable that connects the T1 cards is shown below SYNC Green Synchronisation status indication OFF Not synchronised ON Synchronised Flashing 60 times per minute Synchronised Clock Master Indication Colour Description Diameter Maximum Distance 0 5 mm Under 200 m ...

Страница 85: ...ection RJ45 and BNC cannot be used simultaneously When connecting the RJ45 connector attach the included ferrite core Refer to 2 2 9 Attaching a Ferrite Core This optional service card can be used for either trunk or extension connection by setting the A B switch or using the connector with appropriate pin assignments To confirm the trunk connection refer to Confirming the Trunk Connection in 2 13...

Страница 86: ... or B for extension use When using BNC connectors keep the A position Frame Ground Short Short pin J308 is for BNC TX outer conductor and J309 is for BNC RX outer conductor Connection of 1 and 2 Open default Connection of 2 and 3 Short No Signal Name Level V Function 1 RX Receive data 2 RX Receive data 3 Reserved 4 TX Transmit data 5 TX Transmit data 6 8 Reserved No Signal Name Level V Function 1 ...

Страница 87: ...f Green ON Normal all ports are idle Green Flashing 60 times per minute Normal a port is in use Red ON Fault includes reset Red Flashing 60 times per minute Out of Service SYNC ERR Red Non synchronisation status indication OFF Normal ON Out of synchronisation RAI Red RAI signal status indication OFF Normal ON Alarm Clock Slave Flashing 60 times per minute Alarm Clock Master AIS Red AIS status indi...

Страница 88: ...sion connection by setting the A B switch or using the connector with appropriate pin assignments For details about power failure transfer refer to 2 12 1 Power Failure Connections To confirm the trunk connection refer to Confirming the Trunk Connection in 2 13 1 Starting the Hybrid IP PBX Notice If the connected ISDN terminal has no external power source make sure that the power is supplied from ...

Страница 89: ...1 2 Reserved 3 TX1 Transmit data 1 4 RX2 Receive data 2 5 RX1 Receive data 1 6 TX2 Transmit data 2 7 8 Reserved No Signal Name Level V Function 1 2 Reserved 3 RX2 Receive data 2 4 TX1 Transmit data 1 5 TX2 Transmit data 2 6 RX1 Receive data 1 7 8 Reserved Indication Colour Description CARD STATUS Green Red Card status indication OFF Power Off Green ON Normal all ports are idle Green Flashing 60 ti...

Страница 90: ...hed Master Clock ON Master OFF Slave LINE 8 LINE 7 LINE 6 LINE 5 LINE 4 LINE 3 LINE 2 LINE 1 Green Line status indication LINE 1 to LINE 8 Refer to LINE LED Pattern below for details Note LINE 5 to LINE 8 are for BRI8 card only L1 L2 Master Clock LED Pattern OFF OFF OFF ON OFF OFF ON ON OFF ON OFF ON ON ON ON Indication Colour Description 1 s 1 s 1 s 1 s 1 s ...

Страница 91: ...of S0 Bus Connection The maximum distance of the extension cable that connects the Hybrid IP PBX and the ISDN terminal equipment TE is shown below CAT 5 Under 1000 m TE Point to Point Expansion Point to Multipoint Point to Multipoint TE 1 TE 8 TE 8 TE 1 CAT 5 Under 150 m CAT 5 Under 500 m CAT 5 Under 50 m ...

Страница 92: ... connect to the U interface of the trunk directly Use only 1 type of connector RJ45 or BNC for connection RJ45 and BNC cannot be used simultaneously When connecting the RJ45 connector attach the included ferrite core Refer to 2 2 9 Attaching a Ferrite Core This optional service card can be used for either trunk or extension connection by setting the A B switch or using the connector with appropria...

Страница 93: ...r type to be used A B Slide When using an RJ45 connector select A default for trunk or B for extension use When using BNC connectors keep the A position No Signal Name Level V Function 1 RX Receive data 2 RX Receive data 3 Reserved 4 TX Transmit data 5 TX Transmit data 6 8 Reserved No Signal Name Level V Function 1 TX Transmit data 2 TX Transmit data 3 Reserved 4 RX Receive data 5 RX Receive data ...

Страница 94: ...rt is in use Red ON Fault includes reset Red Flashing 60 times per minute Out of Service SYNC ERR Red Non synchronisation status indication OFF Normal ON Out of synchronisation RAI Red RAI signal status indication OFF Normal ON Alarm Clock Slave Flashing 60 times per minute Alarm Clock Master AIS Red AIS status indication OFF Normal ON Alarm SYNC Green Synchronisation status indication OFF Not syn...

Страница 95: ...Cards KX TDA100 KX TDA200 Installation Manual 95 Maximum Cabling Distance of Extension Connection The maximum distance of the extension cable that connects the PRI30 cards is shown below Diameter Maximum Distance 0 5 mm Under 200 m ...

Страница 96: ...connecting the RJ45 connector attach the included ferrite core except in Canada where the ferrite core is not necessarily required Refer to 2 2 9 Attaching a Ferrite Core This optional service card can be used for either trunk or extension connection by setting the A B switch or using the connector with appropriate pin assignments To confirm the trunk connection refer to Confirming the Trunk Conne...

Страница 97: ...eserved 4 RX Receive data 5 RX Receive data 6 8 Reserved Indication Colour Description CARD STATUS Green Red Card status indication OFF Power Off Green ON Normal all ports are idle Green Flashing 60 times per minute Normal a port is in use Red ON Fault includes reset Red Flashing 60 times per minute Out of Service SYNC ERR Red Non synchronisation status indication OFF Normal ON Out of synchronisat...

Страница 98: ... the extension cable that connects the PRI23 cards is shown below SYNC Green Synchronisation status indication OFF Not synchronised ON Synchronised Flashing 60 times per minute Synchronised Clock Master D LINK Green Data link status indication OFF Not established ON Established Indication Colour Description Diameter Maximum Distance 0 5 mm Under 200 m ...

Страница 99: ...nnector Notes Maximum length of the cable to be connected to this optional service card is 100 m The IP GW4 card occupies the space of 2 free slots when it is installed in the Hybrid IP PBX For programming instructions and other information about the IP GW4 card refer to the documentation for the IP GW4 card To programme the IP GW4 card use the PC programming software designed for the IP GW4 card ...

Страница 100: ...s are idle Green Flashing 60 times per minute Normal a port is in use Red ON Fault includes reset Red Flashing 60 times per minute Out of Service ONLINE Green On line status indication ON On line mode Flashing Emergency maintenance mode ALARM Red Alarm indication OFF Normal ON Alarm IAM BUSY Green Busy status indication OFF Not used ON At least one line is used LINK Green Link status indication OF...

Страница 101: ...Trunk Cards KX TDA100 KX TDA200 Installation Manual 101 SIOSEL Green Serial maintenance port status indication OFF CPU power port used maintenance port not available ON Maintenance port available Indication Colour Description ...

Страница 102: ...pies the space of only 1 free slot when it is installed in the Hybrid IP PBX For programming instructions and other information about the IP GW4E card refer to the documentation for the IP GW4E card To programme the IP GW4E card use the web programming designed for the IP GW4E card To confirm the trunk connection refer to Confirming the Trunk Connection in 2 13 1 Starting the Hybrid IP PBX Pin Ass...

Страница 103: ...ashing 60 times per minute Out of Service ONLINE Green On line status indication ON On line mode OFF Off line mode Flashing Maintenance mode Note If the LINK indicator is OFF the ONLINE indicator will also be OFF ALARM Red Alarm indication OFF Normal ON Alarm VoIP BUSY Green VoIP H 323 process indication OFF VoIP process inactive ON VoIP process active LINK Green Link status indication OFF Connect...

Страница 104: ...INE 8 are for CSIF8 card only When using the CSIF4 card please note that the Hybrid IP PBX software will recognise the CSIF4 card as the CSIF8 card As a result 8 cell stations may appear to be available however only 4 cell stations are supported by the CSIF4 card For details about connecting the CS refer to 2 8 7 Connecting a Cell Station to the Hybrid IP PBX in 2 8 Connection of DECT Portable Sta...

Страница 105: ... Reserved 3 D1 Data port High 4 POWH Power High 5 POWL Power Low 6 D2 Data port Low 7 8 Reserved Indication Colour Description CARD STATUS Green Red Card status indication OFF Power Off Green ON Normal all ports are idle Green Flashing 60 times per minute Normal a port is in use Red ON Fault includes reset Red Flashing 60 times per minute Out of Service 8 1 ...

Страница 106: ...ansfer PFT ports Accessory and User supplied Items Accessory included Screws 2 Ferrite core 1 User supplied not included Amphenol connector Notes Attach the included ferrite core to the cable Refer to 2 2 9 Attaching a Ferrite Core To connect the Amphenol connector refer to 2 2 10 Fastening Amphenol Type Connector For details about power failure transfer refer to 2 12 1 Power Failure Connections L...

Страница 107: ...w 33 D1C PT Data port 3 High 9 Reserved 34 Reserved 10 RD SLT Ring port 4 35 TD SLT Tip port 4 11 D2D PT Data port 4 Low 36 D1D PT Data port 4 High 12 Reserved 37 Reserved 13 RE SLT Ring port 5 38 TE SLT Tip port 5 14 D2E PT Data port 5 Low 39 D1E PT Data port 5 High 15 Reserved 40 Reserved 16 RF SLT Ring port 6 41 TF SLT Tip port 6 17 D2F PT Data port 6 Low 42 D1F PT Data port 6 High 18 Reserved ...

Страница 108: ...n CARD STATUS Green Orange Red Card status indication OFF Power Off Green ON Normal all ports are idle Green Flashing 60 times per minute Normal a port is in use Orange Flashing Detection of PT interface CS connection when starting up the PT interface CS Red ON Fault includes reset Red Flashing 60 times per minute Out of Service ...

Страница 109: ...onsoles and PT interface CSs Accessory and User supplied Items Accessory included Screws 2 Ferrite core 1 User supplied not included Amphenol connector Notes Attach the included ferrite core to the cable Refer to 2 2 9 Attaching a Ferrite Core To connect the Amphenol connector refer to 2 2 10 Fastening Amphenol Type Connector LED Amphenol To extensions ...

Страница 110: ...37 38 Reserved 14 D2E Data port 5 Low 39 D1E Data port 5 High 15 16 Reserved 40 41 Reserved 17 D2F Data port 6 Low 42 D1F Data port 6 High 18 19 Reserved 43 44 Reserved 20 D2G Data port 7 Low 45 D1G Data port 7 High 21 22 Reserved 46 47 Reserved 23 D2H Data port 8 Low 48 D1H Data port 8 High 24 25 Reserved 49 50 Reserved Indication Colour Description CARD STATUS Green Orange Red Card status indica...

Страница 111: ...consoles and PT interface CSs Accessory and User supplied Items Accessory included Screws 2 Ferrite core 1 User supplied not included Amphenol connector Notes Attach the included ferrite core to the cable Refer to 2 2 9 Attaching a Ferrite Core To connect the Amphenol connector refer to 2 2 10 Fastening Amphenol Type Connector LED Amphenol To extensions ...

Страница 112: ...Low 34 D1I Data port 9 High 10 D2J Data port 10 Low 35 D1J Data port 10 High 11 D2K Data port 11 Low 36 D1K Data port 11 High 12 D2L Data port 12 Low 37 D1L Data port 12 High 13 D2M Data port 13 Low 38 D1M Data port 13 High 14 D2N Data port 14 Low 39 D1N Data port 14 High 15 D2O Data port 15 Low 40 D1O Data port 15 High 16 D2P Data port 16 Low 41 D1P Data port 16 High 17 25 Reserved 42 50 Reserved...

Страница 113: ... User supplied Items Accessory included Screws 2 Ferrite core 1 User supplied not included Amphenol connector Notes Attach the included ferrite core to the cable Refer to 2 2 9 Attaching a Ferrite Core To connect the Amphenol connector refer to 2 2 10 Fastening Amphenol Type Connector For details about power failure transfer refer to 2 12 1 Power Failure Connections LED Amphenol To extensions ...

Страница 114: ...ort 4 35 TD Tip port 4 11 12 Reserved 36 37 Reserved 13 RE Ring port 5 38 TE Tip port 5 14 15 Reserved 39 40 Reserved 16 RF Ring port 6 41 TF Tip port 6 17 18 Reserved 43 44 Reserved 19 RG Ring port 7 44 TG Tip port 7 20 21 Reserved 45 46 Reserved 22 RH Ring port 8 47 TH Tip port 8 23 25 Reserved 48 50 Reserved Indication Colour Description CARD STATUS Green Red Card status indication OFF Power Of...

Страница 115: ...C16 card Attach the included ferrite core to the cable Refer to 2 2 9 Attaching a Ferrite Core To connect the Amphenol connector refer to 2 2 10 Fastening Amphenol Type Connector For details about power failure transfer refer to 2 12 1 Power Failure Connections SLC16 16 port extension card for SLTs with 4 power failure transfer PFT ports MSLC16 16 port extension card for SLTs with Message Waiting ...

Страница 116: ...RH Ring port 8 33 TH Tip port 8 9 RI Ring port 9 34 TI Tip port 9 10 RJ Ring port 10 35 TJ Tip port 10 11 RK Ring port 11 36 TK Tip port 11 12 RL Ring port 12 37 TL Tip port 12 13 RM Ring port 13 38 TM Tip port 13 14 RN Ring port 14 39 TN Tip port 14 15 RO Ring port 15 40 TO Tip port 15 16 RP Ring port 16 41 TP Tip port 16 17 25 Reserved 42 50 Reserved Indication Colour Description CARD STATUS Gre...

Страница 117: ...6 card MSG4 card CAUTION A LITHIUM BATTERY IS USED IN OPB3 CARD THERE IS A RISK OF EXPLOSION IF BATTERY IS REPLACED WITH THE INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS LED Indications Indication Colour Description CARD STATUS Green Red Card status indication OFF Power Off Green ON Normal all ports are idle Green Flashing 60 times per minute Normal a port is in use Red O...

Страница 118: ...Items Accessory included Screws 3 10 pin terminal block 1 8 pin terminal block 1 User supplied not included Copper wire Notes Maximum of 3 DPH4 cards can be mounted on the OPB3 card For details about connection to doorphones and door openers refer to 2 10 1 Connection of Doorphones and Door Openers Screw DPH4 Card OPB3 Card Fully insert the connectors through the panel openings To door openers To ...

Страница 119: ...ne 4 receive 3 DP3 Doorphone 3 transmit 4 com3 Doorphone 3 receive 5 DP2 Doorphone 2 transmit 6 com2 Doorphone 2 receive 7 DP1 Doorphone 1 transmit 8 com1 Doorphone 1 receive No Signal Name Function 1 2 Reserved 3 OP4b Door opener 4 4 OP4a Door opener 4 com 5 OP3b Door opener 3 6 OP3a Door opener 3 com 7 OP2b Door opener 2 8 OP2a Door opener 2 com 9 OP1b Door opener 1 10 OP1a Door opener 1 com 8 1...

Страница 120: ...upplied Items Accessory included Screws 3 10 pin terminal block 1 8 pin terminal block 1 User supplied not included Copper wire Notes Maximum of 3 DPH2 cards can be mounted on the OPB3 card For details about connection to doorphones and door openers refer to 2 10 1 Connection of Doorphones and Door Openers Screw DPH2 Card OPB3 Card Fully insert the connectors through the panel openings To doorphon...

Страница 121: ...ne 2 call button 4 Call_2a Doorphone 2 call button com 5 Path_1b Doorphone 1 transmit 6 Path_1a Doorphone 1 receive 7 Call_1b Doorphone 1 call button 8 Call_1a Doorphone 1 call button com No Signal Name Function 1 2 Reserved 3 OP2b Door opener 2 4 OP2a Door opener 2 com 5 OP1b Door opener 1 6 OP1a Door opener 1 com 7 DC2b Doorphone control 2 8 DC2a Doorphone control 2 com 9 DC1b Doorphone control ...

Страница 122: ...U B Path_2a Path_2b DC2b DC2a OP2b 10 9 8 7 6 5 4 3 2 1 Path_1a Path_1b DC1b DC1a OP1b OP1a 8 7 6 5 4 3 2 1 L O U B 12V 8V TO 0 V BL Light RT Call Button OP Door Opener Connection Terminal DC Doorphone Current Supply Control Terminal Path Doorphone Call Path Speaker Microphone Shield Call_2b Call_1a Call_2a Call_1b Doorphone 1 Adaptor 220 V BL Door Opener 1 RT L O U B L O U B 12V 8V TO 0 V German ...

Страница 123: ...d Accessory and User supplied Items Accessory included Screws 3 User supplied not included none Notes To establish a conference call involving 6 to 8 parties install an ECHO16 card and enable the echo cancellation for conference using the KX TDA Maintenance Console refer to 3 3 3 Hybrid IP PBX Configuration Only 1 ECHO16 card can be mounted on the OPB3 card Screw inside ECHO16 Card OPB3 Card ...

Страница 124: ... Manual 2 6 5 MSG4 Card Function 4 channel message card To be mounted on the OPB3 card Accessory and User supplied Items Accessory included Screws 3 User supplied not included none Note Maximum of 3 MSG4 cards can be mounted on the OPB3 card Screw MSG4 Card OPB3 Card inside ...

Страница 125: ...al service card is 100 m This optional service card can be connected to PCs on a LAN via a Server PC to provide third party call control CTI The operating system of the PC or Server PC required for third party call control depends on your CTI application software For details refer to the manual for your CTI application software Pin Assignments RJ45 Connector 10BASE T No Signal Name Input I Output ...

Страница 126: ...ED Indications Indication Colour Description CARD STATUS Green Red Card status indication OFF Power Off Green ON Normal Red ON Fault includes reset Red Flashing 60 times per minute Out of Service LINK STATUS Green Link status indication Flashing In communication ON In normal linking ...

Страница 127: ...16 SLC8 Cards DLC16 DLC8 Cards Cable Maximum Distance ø 0 4 mm Under 500 m ø 0 5 mm Under 720 m ø 0 6 mm Under 830 m CAT 5 Under 720 m Cable Maximum Distance ø 0 4 mm Under 140 m ø 0 5 mm Under 229 m ø 0 6 mm Under 360 m CAT 5 Under 229 m Cable Maximum Distance ø 0 4 mm Under 698 m ø 0 5 mm Under 1128 m ø 0 6 mm Under 1798 m CAT 5 Under 1128 m Other PT and DSS Console SLT KX T7600 Series PT interf...

Страница 128: ...Port XDP mode can be selected through system programming If the XDP mode is enabled through system programming parallel connection is not possible Refer to 1 10 9 Parallelled Telephone and 2 1 1 Extension Port Configuration in the Feature Guide for further information Using a Modular T Adaptor To DHLC8 card 4 conductor wiring cord Connect pins T R D1 and D2 2 conductor wiring cord Connect pins T a...

Страница 129: ...cept KX T7560 and KX T7565 To DHLC8 card DPT SLT To DHLC8 card To SLT 2 conductor wiring cord Connect pins T and R 4 conductor wiring cord Connect pins T R D1 and D2 TO MAIN UNIT PABX TO TEL To DHLC8 card DPT SLT To DHLC8 card To SLT 2 conductor wiring cord Connect pins T and R 4 conductor wiring cord Connect pins T R D1 and D2 TO TEL TO EMSS or TO MAIN UNIT ...

Страница 130: ...lel connection is not possible Refer to 1 10 9 Parallelled Telephone and 2 1 1 Extension Port Configuration in the Feature Guide for further information With KX T7600 Series DPT except KX T7600E Series Using a Modular T Adaptor To DLC8 DLC16 card To DHLC8 card for connection of SLT 4 conductor wiring cord Connect pins D1 and D2 Slave DPT SLT Master DPT Modular T Adaptor 4 conductor wiring cord Con...

Страница 131: ...wiring cord Connect pins T and R 4 conductor wiring cord Connect pins T R D1 and D2 Slave DPT Master DPT To SLT TO MAIN UNIT PABX TO TEL TO TEL TO MAIN UNIT PABX Cable Maximum Distance ø 0 4 mm Under 30 m ø 0 5 mm Under 50 m ø 0 6 mm Under 60 m CAT 5 Under 50 m Back View of DPTs To DLC8 DLC16 card To DHLC8 card for connection of SLT To DLC8 DLC16 card To DHLC8 card for connection of SLT ...

Страница 132: ...ular T Adaptor 4 conductor wiring cord Connect pins D1 and D2 2 conductor wiring cord Connect pins T and R Slave DPT Master DPT TO MAIN UNIT PABX TO DIGITAL TO MAIN UNIT PABX Cable Maximum Distance ø 0 4 mm Under 30 m ø 0 5 mm Under 50 m ø 0 6 mm Under 60 m CAT 5 Under 50 m Back View of DPTs To DLC8 DLC16 card To DHLC8 card for connection of SLT To DLC8 DLC16 card To DHLC8 card for connection of S...

Страница 133: ... conductor wiring cord Connect pins T and R 4 conductor wiring cord Connect pins T R D1 and D2 Slave DPT Master DPT To SLT TO MAIN UNIT PABX TO TEL TO DIGITAL TO MAIN UNIT PABX Cable Maximum Distance ø 0 4 mm Under 30 m ø 0 5 mm Under 50 m ø 0 6 mm Under 60 m CAT 5 Under 50 m Back View of DPTs To DLC8 DLC16 card To DHLC8 card for connection of SLT To DLC8 DLC16 card To DHLC8 card for connection of...

Страница 134: ...t pins D1 and D2 2 conductor wiring cord Connect pins T and R 4 conductor wiring cord Connect pins T R D1 and D2 TO DIGITAL TO MAIN UNIT PABX TO TEL Back View of DPTs Cable Maximum Distance ø 0 4 mm Under 30 m ø 0 5 mm Under 50 m ø 0 6 mm Under 60 m CAT 5 Under 50 m To DLC8 DLC16 card To DHLC8 card for connection of SLT To DLC8 DLC16 card To DHLC8 card for connection of SLT ...

Страница 135: ...X T7601 must be connected to the KX T7633 T7636 DPT Note The operating system of the PC required for first party call control depends on your CTI application software For details refer to the manual for your CTI application software Notes Maximum length of the USB cable is 3 m USB Modules must not be connected to DPTs in the Digital XDP connection In a Digital XDP connection the PC cannot be used ...

Страница 136: ...4 can be connected to the KX TDA200 KX TDA0141CE Using a DHLC DLC Card This unit determines the area covered by the wireless system Up to 2 calls can be made at the same time through each CS Note for users in Europe This Cell Station Unit for DECT is for connection to a Panasonic PBX of a European country PS DECT Portable Station KX TCA155 KX TCA255 KX TD7590 KX TD7580 The KX TDA100 and KX TDA200 ...

Страница 137: ...tance may vary depending on the environment Transmission Output Average 10 mW Peak 250 mW 1 The number may vary depending on the country area In Taiwan it is 1880 MHz to 1895 MHz 2 The number may vary depending on the country area In Taiwan it is 8 Equipment Distance CS and office equipment such as a computer telex fax machine etc or microwaves More than 2 m CS and PS More than 1 m Each PS More th...

Страница 138: ... box d Install each CS temporarily as planned Notes Install at least 2 m above the floor Keep the antennas in the upright position 3 Conduct the site survey Refer to 2 8 5 Site Survey Using the KX TCA255 KX TD7590 a Test the radio signal strength using the PS Confirm that the radio signal strength level is 12 near the CS Using the KX TCA255 Using the KX TD7590 b By walking away from the CS with th...

Страница 139: ... supplying power b Turn off the PS 5 Connect the CS and PS to the Hybrid IP PBX and test the operation Refer to 2 8 7 Connecting a Cell Station to the Hybrid IP PBX a Connect the CSs to the Hybrid IP PBX b Register the PSs to the Hybrid IP PBX c Walk around the service area while having a conversation using a registered PS If noise is frequent or conversations disconnect relocate the CSs or instal...

Страница 140: ...e illustration below shows the special transmitting patterns of radio waves 1 Radio waves are reflected by objects such as those made of metal 2 Radio waves are diffracted by objects such as metallic columns 3 Radio waves penetrate objects like those made of glass Relationships Between Radio Waves and Building Structure and Materials The CS coverage area is affected more by the building materials ...

Страница 141: ...eat resistant film Radio waves are weakened considerably when they penetrate windows Floor Ferroconcrete Radio waves can penetrate them but the more iron there is the more radio waves are reflected Partition Steel Radio waves are reflected and rarely penetrate them Plywood Glass Radio waves usually penetrate them Column Ferroconcrete Radio waves can penetrate them but the more iron there is the mo...

Страница 142: ... information to the map 2 Examine the service area demanded by the user on the map referring to the following example a Draw the coverage area around a CS Extend the coverage area to 30 m to 60 m in one direction depending on the materials of the building structures and obstacles in the installation site Note that a CS cannot be installed outside a building Gray Zone Conversation will be intermitt...

Страница 143: ...PS moves away from a CS and there are no CSs available for handover the PS may go out of range and the call could be lost Example Installing in a Room Separated by Walls Things to take note of The room is separated by walls The room is surrounded by concrete walls CS installation plan The coverage area of each CS will not extend as much it does where there is no obstacle because the radio signals ...

Страница 144: ... ID number using the KX TDA Maintenance Console refer to 3 3 4 Hybrid IP PBX Maintenance Assigning the CS ID Number to the PS Using the KX TCA255 Note To clear the CS ID number assigned to the PS follow the procedure below Press 1 9 and POWER for more than 2 seconds 0 to 7 0 to 9 and A to F CS No CS ID No 1 9 9 2 ABC To enter letters A C E B D F To the initial display To the Desired CS No 3 DEF 4 ...

Страница 145: ... the procedure below Press 1 9 and POWER for more than 5 seconds 0 to 7 0 to 9 and A to F CS No CS ID No 1 9 9 2 ABC To enter letters F1 F2 F3 INT OK A C E B D F To the initial display To the Desired CS No Press 1 9 and POWER for more than 5 seconds 0 to 7 CS No 1 9 9 3 DEF To the Desired CS No OR To clear one by one To clear all at once To the initial display ...

Страница 146: ...Notes To see the radio signal strength of more than 1 CS a channel number must be set for each CS If more than 1 CS is in Radio Signal Test mode each CS must have a unique channel number Channel Number Switch Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 9 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 DIP Switch 1 2 3 4 5 6 OFF ON...

Страница 147: ...tor Note for users in the United Kingdom 240 V AC must not be used on a building site Instead of an AC adaptor connect a battery box to the CS 4 Install the CS temporarily for the site survey Install the CS at least 2 m above the floor keeping the antennas in the upright position To AC Adaptor KX A11 KX TCA1 Battery Box PSZZTD142CE Power Supply Adaptor PSZZ1TDA0142 Modular Telephone Cord ...

Страница 148: ...nged by pressing the appropriate keys 0 through 9 1 Enter the Radio Signal Test mode Using the KX TCA255 Using the KX TD7590 Notes 1 Channel number 2 Slot number 3 When a slot is synchronised SYNC is displayed 4 Radio signal strength level 5 Frame error 0000 to 9999 Frame counter 0000 to 9999 Frame error indicates the number of errors out of 10 000 radio signal receptions An increased number of fr...

Страница 149: ...rom the CS and identify the CS coverage area within which the radio signal strength level is greater than 8 Draw the area on the map c Move away from the CS and identify the CS coverage area within which the radio signal strength level is greater than 3 Draw the area on the map Channel no 0 PS PS PS CH0 L 03 CH0 L 12 Radio Signal Strength Levels Out of range Receives noise easily or disconnects Ma...

Страница 150: ...l strength level is greater than 3 at any location in the service area demanded by the user Notes If a channel is set the results of measurement for the 24 slots on the channel are saved each time If the same channel is set the new results override the previous ones Therefore a measurement of 10 channels 24 slots in total can be made If correct results cannot be obtained e g there are many error c...

Страница 151: ...to clear the scan data Using the KX TCA255 Using the KX TD7590 Press 1 9 and POWER for more than 2 seconds 0 to 9 Log No 1 9 1 Previous or Next 0 to 9 Channel No To go to other slots To go to specific channel A a Press 1 9 and POWER for more than 5 seconds 0 to 9 Log No 1 9 1 Previous or Next 0 to 9 Channel No To go to other slots To go to specific channel Press 1 9 and POWER for more than 2 secon...

Страница 152: ...e proper measurement results exit the Radio Signal Test mode before connecting the CS to the Hybrid IP PBX 1 Keep pressing POWER button on the PS until the PS is turned OFF 2 Disconnect the AC adaptor or battery box from the CS and stop supplying electricity 3 Switch all DIP switches on the CS from ON to OFF 1 2 3 4 5 6 OFF ON ...

Страница 153: ...nd User supplied Items for the CS Accessory included Screws 2 Washers 2 Ferrite core 1 User supplied not included RJ11 connector Note For details about CSIF card refer to 2 5 1 CSIF4 and CSIF8 Card Signal Name Signal Name Pin No 1 2 3 4 D1 POWH POWL D2 D1 POWH POWL D2 Pin No 1 2 3 4 5 6 7 8 CSIF card RJ45 CS RJ11 Cable Maximum Distance ø 0 4 mm Under 444 m ø 0 5 mm Under 694 m ø 0 6 mm Under 1000 ...

Страница 154: ...d Items for the CS Accessory included Screws 2 Washers 2 User supplied not included RJ11 connector Note For details about DHLC card or DLC card refer to 2 5 2 DHLC8 Card 2 5 3 DLC8 Card or 2 5 4 DLC16 Card Signal Name D1 D2 DHLC DLC card Amphenol Cable Maximum Distance ø 0 4 mm Under 222 m ø 0 5 mm Under 347 m ø 0 6 mm Under 500 m CAT 5 Under 347 m Signal Name Pin No 1 2 3 4 D1 D2 CS RJ11 DHLC8 Ca...

Страница 155: ... Installation Manual 155 Connecting the CS 1 Connect the cable from the CSIF DHLC DLC card to the CS 2 Pass the cable through the groove of the CS in any direction depending on your preference Modular To CSIF DHLC DLC card To CSIF DHLC DLC card TO MAIN UNIT PABX ...

Страница 156: ...156 Installation Manual For the KX TDA0142CE User only 3 Wrap the cable once around the ferrite core Then close the case of the ferrite core Note If you need to open the ferrite core use a flathead screwdriver to unlatch the case of the ferrite core To CSIF card ...

Страница 157: ...g and 3 3 PT Programming in the Feature Guide Entering the Hybrid IP PBX System Programming Mode Using a PT Administrator Level Note means default value PS Registration One PS can be registered to a maximum of 4 different Hybrid IP PBXs Using the KX TCA155 KX TCA255 1234 System Password for Administrator for PT Programming Programming No 3 digits PROGRAM PAUSE 690 001 to 128 PS No 1 to 4 digits EN...

Страница 158: ... Registration System Lock Password System Lock Password Press POWER for 5 seconds 4 digits 4 digits ENABLE F SELECT SELECT SELECT OK OK OK C Tone To set system lock F DISABLE OR To register for the first time To re register Select INITIAL SETTING SELECT Select PS PROGRAM SELECT Select DECT SYS SETTING SELECT 4 digits If required OK System Lock Password Select REGISTRATION Select Setting Handset Se...

Страница 159: ... registration will only be used when registering the PS to the Hybrid IP PBX Therefore even when there is more than 1 Hybrid IP PBX with the same PIN near the PS the PS will not be linked to a different Hybrid IP PBX during normal operation after registration Setting the PIN for Hybrid IP PBX Changing the Display Language of the PS Using the KX TCA155 KX TCA255 Using the KX TD7590 Using the KX TD7...

Страница 160: ...PS operation below If Rejected or Time out is displayed CLEAR YES Press YES Press CLEAR 4 digits Handset PIN Select Setting Handset Select Registration Select Base 1 4 Press POWER for 2 seconds C Tone Select YES Select Cancel Base Select the desired item F 0 Select DECT SYS SETTING SELECT 4 digits If required OK System Lock Password Select CANCEL DECT SYS SELECT SELECT Select YES C Tone Press POWE...

Страница 161: ...s KX TDA100 KX TDA200 Installation Manual 161 Testing the Operation Walk around the service area while having a conversation using a registered PS If noise is frequent or conversations disconnect relocate the CSs or install an additional CS ...

Страница 162: ...ace the reference for wall mounting on the following page on the wall to mark the 2 screw positions 2 Install the 2 screws and washers included into the wall Notes Make sure that the screw heads are at the same distance from the wall Install the screws perpendicular to the wall 3 Hook the CS on the screw heads ...

Страница 163: ... Manual 163 Reference for Wall Mounting Please copy this page and use as a reference for wall mounting Note When you print out this page the distance on the paper output may deviate slightly from the measurement indicated above Install a screw here Install a screw here 71 mm ...

Страница 164: ...time through each CS PS 2 4 GHz Portable Station KX TD7680 KX TD7690 The KX TDA100 and KX TDA200 can support up to 128 PSs For more details about the PS refer to the PS Operating Instructions CAUTION The CS should be kept free of dust moisture high temperature more than 40 C low temperature less than 0 C vibration and should not be exposed to direct sunlight The CS should not be placed outdoors us...

Страница 165: ...ration the distance between the CSs when site planning Please consult a certified dealer for details However the required distance between CSs may vary depending on the environment of the installation site and conditions in which the wireless system is used Conduct the site survey to determine the appropriate distance Equipment Distance ...

Страница 166: ...rily as planned Notes Install at least 2 m above the floor Keep the antennas in the upright position 3 Conduct the site survey Refer to 2 9 5 Site Survey a Test the radio signal strength using the PS Confirm that the radio signal strength level is 12 near the CS Using the KX TD7680 Using the KX TD7690 b By walking away from the CS with the PS check the radio signal strength The radio signal streng...

Страница 167: ...the Hybrid IP PBX and test the operation Refer to 2 9 7 Connecting a Cell Station to the Hybrid IP PBX a Connect the CSs to the Hybrid IP PBX b Register the PSs to the Hybrid IP PBX c Walk around the service area while having a conversation using a registered PS If noise is frequent or conversations disconnect relocate the CSs or install an additional CS 6 Mount the CS on the wall Refer to 2 9 8 W...

Страница 168: ...he illustration below shows the special transmitting patterns of radio waves 1 Radio waves are reflected by objects such as those made of metal 2 Radio waves are diffracted by objects such as metallic columns 3 Radio waves penetrate objects like those made of glass Relationships Between Radio Waves and Building Structure and Materials The CS coverage area is affected more by the building materials...

Страница 169: ...heat resistant film Radio waves are weakened considerably when they penetrate windows Floor Ferroconcrete Radio waves can penetrate them but the more iron there is the more radio waves are reflected Partition Steel Radio waves are reflected and rarely penetrate them Plywood Glass Radio waves usually penetrate them Column Ferroconcrete Radio waves can penetrate them but the more iron there is the m...

Страница 170: ...on the map 2 Examine the service area demanded by the user on the map referring to the following example a Draw the coverage area around a CS Extend the coverage area to 30 m to 60 m in one direction depending on the materials of the building structures and obstacles in the installation site Note that a CS cannot be installed outside a building Gray Zone Conversation will be intermittent Coverage ...

Страница 171: ...e lost If the signal from the CS fades due to the structure of the building there may be some handover delay The user will hear a range warning before handover in this case This also applies in the case of interference from 2 4 GHz apparatus Example Installing in a Room Separated by Walls Things to take note of The room is separated by walls The room is surrounded by concrete walls CS installation...

Страница 172: ...et the CS number switches as desired Notes To see the radio signal strength of more than 1 CS a CS number must be set for each CS If more than 1 CS is in Radio Signal Test mode each CS must have a unique CS number CS Number Switch CS no 1 CS no 2 CS no 3 CS no 4 CS no 5 CS no 6 CS no 7 CS no 8 CS no 9 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 DIP Switch 1 2 3 4 5 6 OF...

Страница 173: ...onnect an AC adaptor or battery box to the CS using a power supply adaptor 4 Install the CS temporarily for the site survey Install the CS at least 2 m above the floor keeping the antennas in the upright position To AC Adaptor KX A11 KX TCA1 Battery Box PSZZTD142CE Power Supply Adaptor PSZZ1TDA0142 Modular Telephone Cord ...

Страница 174: ...for the site survey is only in English 1 Enter the Radio Signal Test mode Using the KX TD7680 Using the KX TD7690 Notes 1 CS number and radio signal strength level 2 Scan data test result number Empty memory space will be indicated by a number stored memory space will be indicated by a Display example Press 1 9 and POWER for more than 2 seconds SEARCHING CS NO 1 LEVEL 12 1 SAVE 0123456789 2 1 to 9...

Страница 175: ...ve away from the CS and identify the CS coverage area within which the radio signal strength level is greater than 3 Draw the area on the map 3 Repeat the steps 1 and 2 for other CSs and relocate the CSs when necessary a Overlap adjacent CS coverage areas where the radio signal strength level is 8 by 5 m to 10 m CS no 1 PS PS PS CS NO 1 LEVEL 3 CS NO 1 LEVEL 12 Radio Signal Strength Levels CS NO 1...

Страница 176: ...eferring to the Stored Scan Data Using the KX TD7680 Using the KX TD7690 CS no 1 CS no 2 CS no 3 CS no 4 Press 1 9 and POWER for more than 2 seconds 0 to 9 Scan Data No 1 9 1 Display example When there is scan data When there is no scan data NO 1 CS No 2 LEVEL 9 NO 0 NOT SAVED To the Desired Scan Data No Press 1 9 and POWER for more than 2 seconds 0 to 9 Scan Data No 1 9 1 Display example When the...

Страница 177: ...ting the Stored Scan Data Using the KX TD7680 Using the KX TD7690 Press 1 9 and POWER for more than 2 seconds 0 to 9 or for all data Scan Data No 1 9 To the Desired Scan Data No 2 Press 1 9 and POWER for more than 2 seconds 0 to 9 or for all data Scan Data No 1 9 To the Desired Scan Data No 2 ...

Страница 178: ...the proper measurement results exit the Radio Signal Test mode before connecting the CS to the Hybrid IP PBX 1 Keep pressing POWER button on the PS until the PS is turned OFF 2 Disconnect the AC adaptor or battery box from the CS and stop supplying electricity 3 Switch all DIP switches on the CS from ON to OFF 1 2 3 4 5 6 OFF ON ...

Страница 179: ...cessory and User supplied Items for the CS Accessory included Screws 2 Washers 2 User supplied not included RJ11 connector Note For details about CSIF card refer to 2 5 1 CSIF4 and CSIF8 Card Signal Name Signal Name Pin No 1 2 3 4 D1 POWH POWL D2 D1 POWH POWL D2 Pin No 1 2 3 4 5 6 7 8 CSIF card RJ45 CS RJ11 Cable Maximum Distance ø 0 4 mm Under 444 m ø 0 5 mm Under 694 m ø 0 6 mm Under 1000 m CAT ...

Страница 180: ...ied Items for the CS Accessory included Screws 2 Washers 2 User supplied not included RJ11 connector Note For details about DHLC card or DLC card refer to 2 5 2 DHLC8 Card 2 5 3 DLC8 Card or 2 5 4 DLC16 Card Signal Name D1 D2 DHLC DLC card Amphenol Cable Maximum Distance ø 0 4 mm Under 222 m ø 0 5 mm Under 347 m ø 0 6 mm Under 500 m CAT 5 Under 347 m Signal Name Pin No 1 2 3 4 D1 D2 CS RJ11 DHLC8 ...

Страница 181: ...0 Installation Manual 181 Connecting the CS 1 Connect the cable from the CSIF DHLC DLC card to the CS 2 Pass the cable through the groove of the CS in any direction depending on your preference Modular To CSIF DHLC DLC card To CSIF DHLC DLC card TO MAIN UNIT PABX ...

Страница 182: ...o 2 3 2 PT Programming and 3 3 PT Programming in the Feature Guide Entering the System Programming Mode PT Administrator Level PS Using the KX TD7680 PS Using the KX TD7690 Note means default value throughout this section 1234 System Password for Administrator for PT Programming Programming No 3 digits PROGRAM PAUSE System Setting Menu Select SYSTEM SET Press POWER for 2 seconds Select PS PROGRAM ...

Страница 183: ...en the PS has already been registered to another Hybrid IP PBX One PS can be registered to a maximum of 4 different Hybrid IP PBXs Using the KX TD7680 Using the KX TD7690 690 001 to 128 PS No 1 to 4 digits END ENTER ENTER To the PS operation below Extn No Press POWER for 2 seconds Press S3 for 2 seconds C Tone Press S2 repeatedly to select the desired language F2 F3 Press POWER for 2 seconds Press...

Страница 184: ...ord will be required for PS system setting Using the KX TD7680 Using the KX TD7690 Choose Enable Disable Select SYSTEM LOCK C Tone 4 digits 4 digits ENABLE DISABLE System Lock Password System Lock Password S1 Choose Enable Disable SEL ENTR S1 S1 S1 S1 CHNG SEL ENTR Select SYSTEM LOCK C Tone System Lock Password System Lock Password 4 digits 4 digits ENABLE DISABLE ...

Страница 185: ... 1234 for both the Hybrid IP PBX and PS Therefore the PS can be registered to the Hybrid IP PBX without setting the PIN The PIN for PS registration will only be used when registering the PS to the Hybrid IP PBX Therefore even when there is more than 1 Hybrid IP PBX with the same PIN near the PS the PS will not be linked to a different Hybrid IP PBX during normal operation after registration Settin...

Страница 186: ...the KX TD7690 Testing the Operation Walk around the service area while having a conversation using a registered PS If noise is frequent or conversations disconnect relocate the CSs or install an additional CS 691 001 to 128 PS No ENTER ENTER END To the PS operation below If Rejected or Time out is displayed CLEAR YES Press YES Press CLEAR Select the desired item Select DELETE SYSTEM Select YES C T...

Страница 187: ...lace the reference for wall mounting on the following page on the wall to mark the 2 screw positions 2 Install the 2 screws and washers included into the wall Notes Make sure that the screw heads are at the same distance from the wall Install the screws perpendicular to the wall 3 Hook the CS on the screw heads ...

Страница 188: ...ation Manual Reference for Wall Mounting Please copy this page and use as a reference for wall mounting Note When you print out this page the distance on the paper output may deviate slightly from the measurement indicated above Install a screw here Install a screw here 71 mm ...

Страница 189: ...X TDA200 supports a maximum of 16 doorphones KX T30865 with a DPH4 card or German type with a DPH2 card and a maximum of 16 door openers Notes KX T30865 is a Panasonic doorphone German type doorphones and door openers are user supplied Maximum Cabling Distance Current Limit for door opener 24 V DC 30 V AC 1 A maximum Installing the Doorphone KX T30865 1 Loosen the screw to separate the doorphone i...

Страница 190: ...ch the 2 halves and re insert the screw Connection Use 8 pin and 10 pin terminal blocks included with the card for connection 1 While pressing down on the hole at the top of the terminal block using a screwdriver insert the wire into the side hole as shown below Repeat this procedure for other doorphones and door openers Refer to 2 6 2 DPH4 Card and 2 6 3 DPH2 Card for pin assignments when a doorp...

Страница 191: ...0 Connection of Doorphones and Door Openers KX TDA100 KX TDA200 Installation Manual 191 2 Attach the terminal blocks to the connectors of the DPH4 DPH2 card on the Hybrid IP PBX To doorphones door openers ...

Страница 192: ...usic Jacks are SELV ports and should only be connected to approved SELV devices or in Australia via the Line Isolation Unit with the Telecommunications Compliance Label Note When the Hybrid IP PBX and external music sources are not connected to the same earth hum noise may be induced into Background Music and Music on Hold BGM Music on Hold Pager Amplifier Speaker PC Printer PC Cable Maximum Dista...

Страница 193: ...ogramming SMDR diagnostics and external system database storage save load functions Note Use an RS 232C cross cable for connection between the Hybrid IP PBX and PC Pin Assignments Connection Charts For connecting a printer PC with a 9 pin RS 232C connector No Signal Name Function Circuit Type EIA CCITT 2 RD RXD Receive Data BB 104 3 4 SD TXD ER DTR Transmit Data Data Terminal Ready BA CD 103 108 2...

Страница 194: ... for all interface signals Data Set Ready DSR input An ON condition of circuit DR DSR indicates the printer or the PC is ready Circuit DR DSR ON does not indicate that communication has been established with the printer or the PC Request To Send RTS output This lead is held ON whenever DR DSR is ON Clear To Send CTS input An ON condition of circuit CS CTS indicates that the printer or the PC is re...

Страница 195: ...g diagnostics and external system database storage save load functions The Server PC is used for connecting PCs on a LAN to provide third party call control CTI The CTI connection uses the CSTA Phase 3 or TAPI 2 1 protocol Note The operating system of the PC or Server PC required for third party call control depends on your CTI application software For details refer to the manual for your CTI appl...

Страница 196: ...rd and Extension Card Power Failure Connection connects a specific SLT and a trunk in the event of power failure The following analogue trunk and extension cards can be used for Power Failure Connections Analogue trunk cards LCOT16 4 PFT ports LCOT8 2 PFT port and LCOT4 2 PFT port Extension cards MSLC16 4 PFT ports SLC16 4 PFT ports DHLC8 2 PFT port and SLC8 2 PFT port To 1 analogue trunk card con...

Страница 197: ... RJ11 Connector Pin Assignments for Extension Card PFT Ports 1 and 2 PFT Ports 3 and 4 for MSLC16 SLC16 card only No Signal Name Function 1 R2 Ring port 2 2 R1 Ring port 1 3 T1 Tip port 1 4 T2 Tip port 2 No Signal Name Function 1 R4 Ring port 4 2 R3 Ring port 3 3 T3 Tip port 3 4 T4 Tip port 4 No Signal Name Function 1 T2 Tip port 2 2 T1 Tip port 1 3 R1 Ring port 1 4 R2 Ring port 2 No Signal Name F...

Страница 198: ...ser supplied Items Accessory included none User supplied not included RJ45 connectors Switch Settings RJ45 Connector LINE 1 Pin Assignments Switch Type Usage and Status Definition PFT Setting DIP Set all DIP switches to ON positions to use LINE 1 and LINE 2 as a PFT port LINE 1 Power Failure LINE NT1 LINE 2 Power Failure EXTN extension No Signal Name Level V Function 1 2 Reserved 3 TX1 Transmit da...

Страница 199: ...s KX TDA100 KX TDA200 Installation Manual 199 RJ45 Connector LINE 2 Pin Assignments No Signal Name Level V Function 1 2 Reserved 3 RX2 Receive data 2 4 TX1 Transmit data 1 5 TX2 Transmit data 2 6 RX1 Receive data 1 7 8 Reserved 8 1 ...

Страница 200: ...brid IP PBX and if you unplug the Hybrid IP PBX do not perform the following procedures to start the Hybrid IP PBX again Otherwise your programmed data is cleared To restart the Hybrid IP PBX refer to 4 1 4 Using the Reset Button The Hybrid IP PBX will continue to be powered even if the power switch is turned OFF The power supply cord is used as the main disconnect device ensure that the socket ou...

Страница 201: ...nal service cards except for the IP GW card will be initialised to the default values The DPTs should show the time as 01 00 The data of the IP GW card will not be initialised Notes Use only the AC power cord included with the Hybrid IP PBX for the PSU Use only the supplied AC power cord for the purpose of applying the EMC standard if the Hybrid IP PBX is connected Germany only LED Indications Ind...

Страница 202: ...al Confirming the Trunk Connection After initialisation programme the Hybrid IP PBX and establish trunk connection and then use a PT to confirm it To confirm dial 3 7 trunk number 3 digits or press S CO button You will hear a dial tone if the trunk is available and connected ...

Страница 203: ...Installation Manual 203 Section 3 Guide for the KX TDA Maintenance Console KX TDA100 KX TDA200 Explains the installation procedure structure and basic information of the KX TDA Maintenance Console ...

Страница 204: ...rogramming reference for the Hybrid IP PBX To programme and administer the Hybrid IP PBX by PC you need to install the KX TDA Maintenance Console onto the PC This manual describes overview and installation of the KX TDA Maintenance Console only KX TDA Maintenance Console 1 1 The contents and design of the software are subject to change without notice Menu Bar Programme Menu ...

Страница 205: ...nterface Connection Note For pin assignments and maximum cabling distance refer to 2 11 1 Connection of Peripherals LAN Connection via CTI LINK Card Note For pin assignments and maximum cabling distance refer to 2 6 6 CTI LINK Card PC USB Port To USB Port To COM Port RS 232C Port PC PC Switching Hub To network port RJ45 ...

Страница 206: ...ion should be disabled Error Correction is not necessary Notes Use an RS 232C straight cable for connection between the Hybrid IP PBX and external modem An AT command for initialisation enabling automatic answer etc can only be programmed by KX TDA Maintenance Console AT F0E0V1X1S10 30S12 50 is stored as the default value For more information about the AT command refer to the external modem s inst...

Страница 207: ...stem password 1 Please inform the customer of the importance of the password and the possible dangers 2 Please maintain the secrecy of the password This will avoid unauthorised access and possible dial through fraud 3 Please change the password periodically 4 We strongly recommend that a password of 10 digits is used for maximum protection against hackers 5 If the system password is forgotten you ...

Страница 208: ...id IP PBX The date and time set on the PC will be used System Password for installer for PC programming Operator extension numbers Operator extensions for all time modes day lunch break night can be assigned Flexible Numbering type to pattern 1 or pattern 2 If pattern 1 with is selected must prefix all feature numbers except access numbers when an extension user wants to use a feature Operator cal...

Страница 209: ...nce Console with the Installer Level Programmer Code Note There are 2 other Programmer Codes with limited authorisation Administrator Level default 1111 and User Level default none 4 Click Connect USB from the menu bar 5 Type the system password for installer default 1234 then click OK to log in 6 When country area data do not match a Click OK to replace the country area data of the Hybrid IP PBX ...

Страница 210: ... the KX TDA Maintenance Console so that the PBX starts automatically saving the system data 2 When the PBX is initialised not all data is taken from the SD Memory Card The data for present status of extension FWD DND buttons is taken from battery backup memory in the PBX 3 The PC will not perform any shutdown operation or enter the power saving system standby mode while the KX TDA Maintenance Cons...

Страница 211: ... Diagnosis File Transfer PC to PBX SD Card Reset by the Command Window Help File Transfer PBX SD Card to PC SD Card File View and Load SD Card File Delete Message File Transfer PC to PBX Message File Transfer PBX to PC Error Log T1 E1 Signaling Bit Monitor T1 E1 Line Trace ISDN Qsig Protocol Trace Digital Trunk Error Report CS Information PS Information Timed Update System Reset ...

Страница 212: ...ch feature and related PT programming refer to the on line help at each screen 1 Start the KX TDA Maintenance Console refer to Starting the KX TDA Maintenance Console and Assigning the Basic Items Quick Setup in 3 3 1 Installing and Starting the KX TDA Maintenance Console 2 To check the slot condition of the Hybrid IP PBX a Double click Configuration b Double click Slot 3 To check the PS status a ...

Страница 213: ...eature and related PT programming refer to the on line help at each screen 1 Start the KX TDA Maintenance Console refer to Starting the KX TDA Maintenance Console and Assigning the Basic Items Quick Setup in 3 3 1 Installing and Starting the KX TDA Maintenance Console 2 To diagnose a card Click Utility Diagnosis from the menu bar 3 a Click Status of the desired card and change its status to OUS b ...

Страница 214: ...is installed Message File Transfer PBX to PC The message files for Outgoing Messages in the MSG cards mounted on the OPB3 card are transferred to the PC Available only when at least 1 MSG card is installed Error Log The error log is displayed for details refer to 4 1 5 Troubleshooting by Error Log T1 E1 Signaling Bit Monitor Monitors the sent and received signalling bits on T1 E1 line T1 E1 Line T...

Страница 215: ...al 215 System Reset Reset by the Command Resets the connected Hybrid IP PBX It is the same as pushing the Reset Button with the System Initialise Switch in the NORMAL position After using this command you have to restart the KX TDA Maintenance Console and connect to the Hybrid IP PBX again ...

Страница 216: ...3 3 Installation of the KX TDA Maintenance Console KX TDA100 KX TDA200 216 Installation Manual ...

Страница 217: ...Installation Manual 217 Section 4 Troubleshooting KX TDA100 KX TDA200 This section provides information on the Hybrid IP PBX and telephone troubleshooting ...

Страница 218: ... the appropriate type Improper operation Press the Reset Button refer to 4 1 4 Using the Reset Button Noise on external paging Induced noise on the wire between the Hybrid IP PBX and the amplifier Use a shielded cable as the connection wire between the Hybrid IP PBX and amplifier A short shielded cable is recommended Distorted external music Excessive input level from external music source Decreas...

Страница 219: ...res are for T R and the outer 2 wires are for D1 D2 D1 T R D2 D1 T R D2 Hybrid IP PBX Hybrid IP PBX Hybrid IP PBX Extension CAUSE The T R is connected to the D1 D2 SOLUTION Use the correct cord the inner 2 wires are for T R D1 T R D2 T R Extension CAUSE The T is connected to the R SOLUTION Reverse the connections of the T R D1 T R D2 T R Extension Can you dial an extension Continued on the next pa...

Страница 220: ...rid IP PBX CAUSE Trunk is connected to the T2 T1 Trunk is connected to the T2 R1 SOLUTION Reconnect the trunk to the T1 R1 or T2 R2 of the telephone jack using 2 conductor wiring T2 R1 T1 R2 Trunk Hybrid IP PBX Hybrid IP PBX Trunk T2 R1 T1 R2 Continued from the previous page Can you dial out on a trunk No ...

Страница 221: ...ure extensions connected to ports 1 to 4 of MSLC16 SLC16 and ports 1 to 2 of DHLC8 SLC8 cards do not operate A DPT or APT is connected to the extension port The dialling mode tone or pulse is incorrect Disconnect the DPT or APT and connect an SLT Set the Tone Pulse switch to the other position Originating an outside call call transfer or conference cannot be performed The corresponding CO button d...

Страница 222: ...KX TCA255 KX TD7590 or 2 9 5 Site Survey Access system of the PS is not properly set Change the access system setting of the PS to the appropriate system or automatic Noise is frequent while using the PS Conversations disconnect while using the PS Call handover is not working PS is out of CS coverage area Locate the CS properly refer to 2 8 5 Site Survey Using the KX TCA255 KX TD7590 or 2 9 5 Site...

Страница 223: ...ou must press the Reset Button with caution because all data stored in memory will be cleared by the following operation 1 pressing the Reset Button and then 2 setting the System Initialise Switch to the NORMAL position while the RUN indicator is flashing within approximately 10 s Operation 1 If the Hybrid IP PBX does not operate properly a Make sure that the System Initialise Switch is set to the...

Страница 224: ...does not work a Unplug the Hybrid IP PBX b Set the System Initialise Switch to the SYSTEM INITIALIZE position c Plug in the Hybrid IP PBX after 5 min d Press the Reset Button e Set the System Initialise Switch to the NORMAL position while the RUN indicator is flashing within approximately 10 s ...

Страница 225: ... Hybrid IP PBX Maintenance Example KX TDA Maintenance Console Example Station Message Detail Recording SMDR Description Item Description 1 Date Date of the error detection 2 Time Time of the error detection 3 Level Major Alarm MJ ALM Errors that affect the whole system operation or result in system failure Minor Alarm MN ALM Errors that affect certain part of system operation 4 Error Code Three di...

Страница 226: ...to 11 00 MPR slot 01 to 10 Free slot 11 Option slot YY Physical port number 01 to 16 For OPB3 card sub slot number port number will be displayed Sub slot 1 11 to 14 Sub slot 2 21 to 24 Sub slot 3 31 to 34 Note When there is no parameter for slot and physical port number XX and YY will be displayed as 00 Example Sub code for MPR card 10000 6 Error Message Error description maximum 36 characters Ite...

Страница 227: ...ared from the KX TDA Maintenance Console LPR Optional Service Card with Local Processor Initial Self Diagnosis Error Code Error Message PROBABLE CAUSE SOLUTION 211 Speech path loop back check error Optional service card malfunction DHLC DLC SLC CSIF LCOT T1 E1 BRI PRI OPB3 E M IP GW DID See if the corresponding optional service card is installed properly Pull out and re insert the corresponding op...

Страница 228: ...rouble with UPS Bad connection or breaking of AC cord Power supply circuit PSU back board malfunction Check the power supply system See if the AC cord is connected properly Check the AC cord Replace the AC cord be sure to turn off the Hybrid IP PBX when replacing Replace the PSU be sure to turn off the Hybrid IP PBX when replacing Replace the back board be sure to turn off the Hybrid IP PBX when r...

Страница 229: ...s error SD Memory Card malfunction Bad connection of SD Memory Card MPR card malfunction Press the Reset Button Reprogramme the Hybrid IP PBX Replace the SD Memory Card Replace the MPR card be sure to turn off the Hybrid IP PBX when replacing 021 SD Memory Card disconnected SD Memory Card not installed Bad connection of SD Memory Card SD Memory Card malfunction MPR card malfunction 022 Not enough ...

Страница 230: ...of SD Memory Card SD Memory Card malfunction MPR card malfunction Press the Reset Button Reprogramme the Hybrid IP PBX Replace the SD Memory Card Replace the MPR card be sure to turn off the Hybrid IP PBX when replacing 032 System initialization file not found 033 Card initialization file not found 034 LCD file not found 035 System data file access error 036 System initialization file access error...

Страница 231: ...stalled properly Optional service card malfunction Back board malfunction See if the corresponding optional service card is installed properly Pull out and re insert the corresponding optional service card Press the Reset Button Replace the corresponding optional service card Replace the back board be sure to turn off the Hybrid IP PBX when replacing 231 LPR alive check error Optional service card...

Страница 232: ...een the CS and CSIF card or DHLC DLC card failed Data link between the network and PRI BRI card failed Data link between the network and IP GW card failed Check the connection between the CS and CSIF card or DHLC DLC card Check the connection between the network and PRI BRI card Check the connection between the network and IP GW card 306 E1 Channel Block failure Network digital trunk malfunction O...

Страница 233: ...Check the Gatekeeper setting 323 IP GW SDRAM Failure Detection of IP GW SDRAM error Replace the corresponding optional service card 324 IP GW DPRAM Failure Detection of IP GW DPRAM error Replace the corresponding optional service card 325 IP GW LAN Chip Failure Detection of IP GW LAN Chip failure Replace the corresponding optional service card Collect the log data of IP GW refer to the documentati...

Страница 234: ...roper card is selected as the new clock master card 393 LAN Carrier detected IP GW card connected to the LAN This information is logged when synchronisation of LAN is established 394 IP GW Core Data Link established IP GW Core Data Link established This information is logged when IP GW Core Data Link is recovered 395 IP GW Gatekeeper Error Cleared Connection to the Gatekeeper is recovered This inf...

Страница 235: ...Installation Manual 235 Section 5 System Outline KX TDA30 This section provides general information on the Hybrid IP PBX including the system capacity and specifications ...

Страница 236: ...s are waiting in the queue the calls are handled by the Queuing Time Table which can be assigned for each time mode day lunch break night Log in Log out Incoming call distribution group members can join Log in or leave Log out the groups manually While logged in a member extension can have a preprogrammed time period automatically for refusing calls after completing the last call Wrap up VIP Call ...

Страница 237: ... telephone to act as an independent extension with its own extension number Digital XDP A DPT can be connected to another DPT which is connected to a DPT port or a Super Hybrid Port of the PBX Similar to XDP mode each DPT acts as an independent extension with its own extension number Portable Station PS Features PSs e g KX TD7690 can be connected to this Hybrid IP PBX It is possible to use the Hyb...

Страница 238: ...ic System Construction KX TDA30 5 2 1 Main Unit The main unit is equipped with 4 Super Hybrid Ports For system expansion optional service cards can be installed and an additional AC adaptor can also be connected Construction of Main Unit Main Board Front Cover Cable Cover ...

Страница 239: ... Hold MOH Pager Speaker Batteries Voice Processing System KX T7636 KX T7633 Remote PC PC Printer Router Private IP Network Trunk Telephone Company Lines Analogue BRI Hybrid IP PBX SLT CS PS Wireless Phone Fax Machine PC USB KX T7600 DPT KX T7600 DPT APT DSS Console DSS Console DPT ISDN Telephone Amplifier Server PC PC PC SLT DPT ...

Страница 240: ...runk Digital Trunk ISDN BRI Line Digital Trunk DLC8 KX TDA3172 DLC4 KX TDA3171 SLC8 KX TDA3174 SLC4 KX TDA3173 DPH4 KX TDA3161 DPH2 KX TDA3162 ECHO8 KX TDA3166 EXT CID KX TDA3168 MEC KX TDA3105 MSG2 KX TDA3191 IP GW4 KX TDA3480 DID4 KX TDA3182 LCOT2 KX TDA3183 BRI2 KX TDA3280 BRI1 KX TDA3283 Telephone Company SLT Wireless Phone Fax Machine Hybrid IP PBX DPT APT DPT DSS Console Voice Processing Sys...

Страница 241: ...ital Extension Card DLC4 4 port digital extension card for DPTs DSS consoles a Voice Processing System VPS and PT interface CSs 1 KX TDA3172 8 Port Digital Extension Card DLC8 8 port digital extension card for DPTs DSS consoles a VPS and PT interface CSs 2 KX TDA3173 4 Port Single Line Telephone Extension Card SLC4 4 port extension card for SLTs 1 KX TDA3174 8 Port Single Line Telephone Extension ...

Страница 242: ...ate Interface card with 1 power failure transfer PFT port EURO ISDN ETSI compliant 3 KX TDA3283 1 Port BRI Card BRI1 1 port ISDN Basic Rate Interface card EURO ISDN ETSI compliant 3 KX TDA3480 4 Channel VoIP Gateway Card IP GW4 4 channel VoIP gateway card VoIP H 323 V 2 ITU T G 729a G 723 1 and G 711 compliant 1 KX A236 Additional AC Adaptor AC adaptor and AC cord for system expansion 1 Model No M...

Страница 243: ...l Pulse DP 10 pps 20 pps Tone DTMF Dialling Connectors Trunk RJ45 RJ11 2 wire each trunk port Extension RJ45 RJ11 4 wire each extension port Paging Output 1 conductor jack External MOH Music on Hold Output 1 conductor jack Mode Conversion DP DTMF DTMF DP Ring Frequency 20 Hz 25 Hz selectable Trunk Loop Limit 1600 maximum Operating Environment Temperature 0 C to 40 C Humidity 10 to 90 non condensin...

Страница 244: ...ection Cable SLT 1 pair wire T R DPT 1 pair wire D1 D2 or 2 pair wire T R D1 D2 APT 2 pair wire T R D1 D2 PT interface CS 1 pair wire D1 D2 DSS Console and Add on Key Module 1 pair wire D1 D2 Dimension 275 mm W 376 mm H 117 mm D Weight when fully mounted Under 3 5 kg ...

Страница 245: ...llel or eXtra Device Port connection of a PT and an SLT 3 by Digital eXtra Device Port connection of two DPTs and an SLT Ring Voltage 75 Vrms at 20 Hz 25 Hz depending on the Ringing Load Trunk Loop Limit 1600 maximum Hookswitch Flash Recall Timing Range 24 ms to 2032 ms BRI Cards Internal ISDN Mode Supply Voltage 40 V Power Supply 4 5 W per 1 line 5 W per 2 lines Power Supply Method Phantom Power ...

Страница 246: ... conditions A total of more than 4 APTs and DPTs except KX T7600 series KX T7560 KX T7565 are connected More than 4 CSs are connected For how to connect an AC adaptor or additional AC adaptor refer to 6 12 1 Starting the Hybrid IP PBX Line Type Maximum Number Trunk Line 12 VoIP Line 4 Terminal Equipment Type Without an Additional AC Adaptor With an Additional AC Adaptor SLT 24 24 KX T7600 series D...

Страница 247: ...figures can be supported Equipment Type Load Figure SLT 0 PT KX T7600 series DPT and KX T7560 KX T7565 DPT 0 Other types of DPT 4 APT 4 CS 4 ISDN Telephone 1 1 1 If the connected ISDN telephone has an external power source its load figure is 0 Connected AC Adaptor Maximum Supplied AC Adaptor only 32 Supplied AC Adaptor and Additional AC Adaptor 96 1 1 If the load figure exceeds 96 it cannot be sup...

Страница 248: ...5 4 Specifications KX TDA30 248 Installation Manual ...

Страница 249: ...s the procedures to install the Hybrid IP PBX Detailed instructions for planning the installation site installing the optional service cards and cabling of peripheral equipment are provided Further information on system expansion and peripheral equipment installation is included ...

Страница 250: ...huric gases produced in areas where there are thermal springs etc may damage the equipment or contacts 3 Places in which shocks or vibrations are frequent or strong 4 Dusty places or places where water or oil may come into contact with the unit 5 Near high frequency generating devices such as sewing machines or electric welders 6 On or near computers telexes or other office equipment as well as mi...

Страница 251: ...uring wiring After the wiring is completed turn the power switch on 6 Mis wiring may cause the Hybrid IP PBX to operate improperly 7 If an extension does not operate properly disconnect the telephone from the extension line and then connect again or turn the power to the Hybrid IP PBX off and on again 8 The Hybrid IP PBX is equipped with a 3 wire earthing type plug This is a safety feature If you ...

Страница 252: ...llation of the Hybrid IP PBX KX TDA30 6 2 1 Unpacking Unpack the box and check the items below Main Unit 1 AC Cord 1 AC Adaptor 1 Screws for Wall Mounting 5 Washers for Wall Mounting 5 Mini Plug for pager and music source 2 SD Memory Card 1 Main Strap 1 Optional Card Label Sheet 1 ...

Страница 253: ...TDA30 Installation Manual 253 6 2 2 Names and Locations SD Memory Card Slot Cover Reset Button MOH port Pager port Super Hybrid Ports RS 232C port USB port System Initialise Switch DC IN 2 DC IN 1 Earth Terminal Battery Connector Power Switch ...

Страница 254: ...he Covers Opening the Covers 1 Pull the slide button to the right and holding it slide the cable cover upwards Then turn the cable cover slightly to remove it 2 Remove the three screws 3 Holding the protrusions on both sides of the front cover swing the cover open Slide Button Cable Cover Screw ...

Страница 255: ...f you prefer you can remove the front cover Removing the Front Cover Holding the front cover open at about a 45 angle remove the front cover by pushing it in the direction of the arrow as shown below Attaching the Front Cover Fit the front cover to the main unit as shown below and then close the front cover ...

Страница 256: ...ual Closing the Covers 1 Close the front cover then tighten the three screws 2 Attach the rear hooks on the cable cover to the main unit then swing the cable cover closed so that the front hooks fit in place 3 Slide the cable cover down until it locks Screw Cable Cover ...

Страница 257: ...P PBX and all the customer data The SD Memory Card must be inserted before start up Do not remove the SD Memory Card during the operation of the Hybrid IP PBX Removing the SD Memory Card during operation may cause damage to the SD Memory Card or result in loss of data LED Indications Note If you need to remove the SD Memory Card Indication Colour Description SD ACCESS Green SD memory card status O...

Страница 258: ...ser of electrocution in the case of lightning strike The earthing wire of the AC cable has an effect against the external noise and lightning strikes but it may not be enough to protect the Hybrid IP PBX A permanent connection between earth and the earth terminal of the Hybrid IP PBX must be made 1 Loosen the screw 2 Insert an earthing wire user supplied 3 Tighten the screw 4 Connect the earthing ...

Страница 259: ...tery charge may not be maintained Make sure that the type and capacity of the 3 backup batteries are identical The Back up Battery Cable should not be exposed to direct sunlight Keep the Back up Battery Cable and the backup batteries away from heating appliances and fire Place the backup batteries in ventilated place For details about the backup batteries refer to the manual intended for the batte...

Страница 260: ...he optional service card 1 Slots 10 and 11 accept only cards which do not have external ports Therefore these slots do not have removable cover plates 2 Slot 01 contains the pre installed Super Hybrid Ports No optional service card can be installed Card Slot Number Type Max 02 03 04 05 06 07 08 09 10 11 LCOT4 3 LCOT2 3 DID4 3 BRI2 3 BRI1 3 DLC4 1 1 SLC4 IP GW4 1 DLC8 2 2 SLC8 DPH4 1 3 DPH2 ECHO8 1...

Страница 261: ...1 Options Any card that exceeds the capacity of the Hybrid IP PBX will be ignored When the Hybrid IP PBX starts up with an invalid configuration some cards will be ignored Installing Optional Service Cards 1 Before installing the optional service cards cut and remove the appropriate dummy cover plates from the main unit CAUTION For safety reasons smooth the cut edges after removing the dummy cover...

Страница 262: ...in place lower the rear end so that the hole of the card fits over the extension bolt CAUTION When installing the optional service cards do not put pressure on any parts of the main board Doing so may result in damage to the Hybrid IP PBX 3 Insert the new extension bolt included with the card into the hole on the card and tighten it to secure the card 1 2 Extension Bolt Optional Service Card Exten...

Страница 263: ...orresponding card 5 Connect a cable to an appropriate port of the card For details about pin assignments refer to the appropriate section in 6 3 Installation of the Trunk Cards KX TDA30 and 6 4 Installation of the Extension Cards KX TDA30 Note Make sure to connect cables after installing the card in the Hybrid IP PBX not before Optional Card Label ...

Страница 264: ...64 Installation Manual 6 Repeat the procedure for other cards A When installing a card in Slot 07 make sure to detach the LED holder first After installing the card reattach the LED holder To detach the LED holder To attach the LED holder LED holder ...

Страница 265: ...6 2 Installation of the Hybrid IP PBX KX TDA30 Installation Manual 265 B When installing a card in Slot 11 tighten the card using the screw included with the card instead of the extension bolt Screw ...

Страница 266: ... PBX KX TDA30 266 Installation Manual Handling of the Cables 1 Attach the strap included with the card to one of the connected cables 2 Bind all the connected cables together using the strap 3 Repeat the procedure for other cards Strap ...

Страница 267: ...6 2 Installation of the Hybrid IP PBX KX TDA30 Installation Manual 267 4 Attach the main strap included with the Hybrid IP PBX to any of the 5 rails depending on your preference 2 1 Main Strap ...

Страница 268: ... and then close the cable cover For how to close the cable cover refer to 6 2 3 Opening Closing the Covers Notes For safety reasons do not stretch bend or pinch the cables If you prefer you can cut the other side of the cable cover and run the cables through that opening For safety reasons smooth the cut edges Main Strap Cable Cover ...

Страница 269: ...nal Service Cards 1 Loosen and remove the extension bolt 2 Holding the protrusions of the card pull the card in the direction of the arrows CAUTION When removing the optional service cards do not put pressure on any parts of the main board Doing so may result in damage to the Hybrid IP PBX ...

Страница 270: ... TDA3180NE LCOT2 KX TDA3183 BRI2 KX TDA3280 BRI1 KX TDA3283 IP GW4 KX TDA3480 Super Hybrid Ports Main Board 1 Twisted pair cable DPH4 KX TDA3161 DLC4 KX TDA3171 DLC8 KX TDA3172 SLC4 KX TDA3173 SLC8 KX TDA3174 LCOT4 KX TDA3180 DID4 KX TDA3182 Super Hybrid Ports Main Board 2 DPH4 KX TDA3161 DPH2 KX TDA3162 Main Board Main Board Main Board Pager port MOH port RJ45 1 8 RJ11 4 1 10 pin Terminal Block 8...

Страница 271: ...lation Manual 271 1 The KX TDA30E the KX TDA30NE and the KX TDA30GR have the Super Hybrid Ports with RJ45 connectors 2 Other models of the KX TDA30 other than the KX TDA30E the KX TDA30NE and the KX TDA30GR have the Super Hybrid Ports with RJ11 connectors ...

Страница 272: ...e sure that the screw heads are at the same distance from the wall Install the screws perpendicular to the wall 3 Hook the main unit on the screw heads Notes Do not block the openings of the cabinet Allow space of at least 20 cm above and 10 cm at the sides of the cabinet Make sure that the wall behind the cabinet is flat and free of obstacles so that the openings on the back of the cabinet will n...

Страница 273: ...ny metal laths wire laths or metal plates in the wall 1 Place the reference for wall mounting on the last page of this manual on the wall to mark the 3 screw positions 2 Install three anchor plugs user supplied in the wall 3 Install the screws included in the wall 4 Hook the main unit on the screw heads 250 mm 130 mm Hammer 29 mm Anchor Plug 6 4 mm Drive the screw to this position ...

Страница 274: ... block the openings of the cabinet Allow space of at least 20 cm above and 10 cm at the sides of the cabinet Make sure that the wall behind the cabinet is flat and free of obstacles so that the openings on the back of the cabinet will not be blocked Be careful not to drop the cabinet ...

Страница 275: ...on the following page on the wall to mark the 2 screw positions 2 Install the screws and washers included in the wall Notes Make sure that the screw heads are at the same distance from the wall Install the screws perpendicular to the wall 3 Hook the AC adaptor on the screw heads Note Be careful not to drop the AC adaptor 110 mm Washer Drive the screw to this position ...

Страница 276: ...s wire laths or metal plates in the wall 1 Place the reference for wall mounting on the following page on the wall to mark the 2 screw positions 2 Install two anchor plugs user supplied in the wall 3 Install the screws included in the wall 4 Hook the AC adaptor on the screw heads Note Be careful not to drop the AC adaptor 110 mm Hammer 29 mm Anchor Plug 6 4 mm Drive the screw to this position ...

Страница 277: ...277 Reference for Wall Mounting Please copy this page and use as a reference for wall mounting Note When you print out this page the distance on the paper output may deviate slightly from the measurement indicated above Install a screw here Install a screw here 110 mm ...

Страница 278: ...iring the installation of lightning protection A lightning strike to a telephone cable which is 10 m above ground can be as high as 200 000 V The Hybrid IP PBX must be installed with lightning protectors In addition earthing connection to earth is very important for the protection of the user Be sure to comply with applicable local regulations e g law guidelines Recommended Lightning Protectors KX...

Страница 279: ...protect the wire Note The lightning protector for an extension and CS is different from that for trunks Installation of an Earth Rod 1 Installation location of the earth rod Near the protector CS SLT PT Main Building Trunk Trunk Extn Extn Extn Extension Line Earth Another Building Extn Extn Lightning Protectors Terminal Board Lightning Protector SLT PT Hybrid IP PBX CS Trunk Hybrid IP PBX Earthing...

Страница 280: ...uctions None 3 Composition of the earth rod Metal 4 Depth of the earth rod More than 50 cm 5 Cross sectional area of the earthing wire More than 1 3 mm2 Notes The above figures are recommendations only The length of earth rod and the required depth depend on the composition of the soil ...

Страница 281: ...tems Accessory included Extension Bolt 1 Strap 1 User supplied not included RJ45 connector or RJ11 connector Notice The connector type may be RJ45 or RJ11 depending on the country area Notes To confirm the trunk connection refer to Confirming the Trunk Connection in 6 12 1 Starting the Hybrid IP PBX For details about power failure transfer refer to 6 11 1 Power Failure Connections Pin Assignments ...

Страница 282: ...6 3 Installation of the Trunk Cards KX TDA30 282 Installation Manual RJ11 Connector Signal Name Function R Ring T Tip Reserved 4 1 T R ...

Страница 283: ...ry included Extension Bolt 1 Strap 1 User supplied not included RJ45 connector Notes To confirm the trunk connection refer to Confirming the Trunk Connection in 6 12 1 Starting the Hybrid IP PBX For details about power failure transfer refer to 6 11 1 Power Failure Connections Pin Assignments RJ45 Connector Signal Name Function R Ring T Tip Reserved To trunk RJ45 PFT Port 1 PFT Port 2 9 16 1 8 T R...

Страница 284: ...ory and User supplied Items Accessory included Extension Bolt 1 Strap 1 User supplied not included RJ11 connector Note To confirm the trunk connection refer to Confirming the Trunk Connection in 6 12 1 Starting the Hybrid IP PBX Pin Assignments RJ11 Connector Signal Name Function R Ring T Tip Reserved To trunk RJ11 4 1 T R ...

Страница 285: ...ard Function 4 port Caller ID signal type FSK FSK with Call Waiting Caller ID Visual Caller ID DTMF To be mounted on the LCOT4 card Accessory and User supplied Items Accessory included none User supplied not included none Note If you need to remove the CID4 Card CID4 Card LCOT4 Card ...

Страница 286: ...ion connection by setting the A B switch or using the connector with appropriate pin assignments For details about power failure transfer refer to 6 11 1 Power Failure Connections To confirm the trunk connection refer to Confirming the Trunk Connection in 6 12 1 Starting the Hybrid IP PBX Notice If the connected ISDN terminal has no external power source make sure that the power is supplied from t...

Страница 287: ...eceive data 1 TX2 Transmit data 2 Reserved Signal Name Level V Function RX2 Receive data 2 TX1 Transmit data 1 TX2 Transmit data 2 RX1 Receive data 1 Reserved Indication Colour Description LINE 1 Green LINE 1 status indication Refer to LINE LED Pattern below for details LINE 2 Green LINE 2 status indication Refer to LINE LED Pattern below for details L1 L2 Master Clock LED Pattern OFF OFF OFF ON O...

Страница 288: ...istance of S0 Bus Connection The maximum distance of the extension cable that connects the Hybrid IP PBX and the ISDN terminal equipment TE is shown below ON ON OFF ON OFF ON ON ON ON L1 L2 Master Clock LED Pattern 1 s 1 s 1 s CAT 5 Under 1000 m TE Point to Point Expansion Point to Multipoint Point to Multipoint TE 1 TE 8 TE 8 TE 1 CAT 5 Under 150 m CAT 5 Under 500 m CAT 5 Under 50 m ...

Страница 289: ...n be used for either trunk or extension connection by setting the A B switch or using the connector with appropriate pin assignments To confirm the trunk connection refer to Confirming the Trunk Connection in 6 12 1 Starting the Hybrid IP PBX Notice If the connected ISDN terminal has no external power source make sure that the power is supplied from the BRI1 card by programming the Hybrid IP PBX a...

Страница 290: ...it data 1 RX2 Receive data 2 RX1 Receive data 1 TX2 Transmit data 2 Reserved Signal Name Level V Function RX2 Receive data 2 TX1 Transmit data 1 TX2 Transmit data 2 RX1 Receive data 1 Reserved Indication Colour Description LINE 1 Green LINE 1 status indication Refer to LINE LED Pattern below for details L1 L2 Master Clock LED Pattern OFF OFF OFF ON OFF OFF ON ON OFF 1 8 TX1 RX2 RX1 TX2 RX2 TX1 TX2...

Страница 291: ...bling Distance of S0 Bus Connection The maximum distance of the extension cable that connects the Hybrid IP PBX and the ISDN terminal equipment TE is shown below ON OFF ON ON ON ON L1 L2 Master Clock LED Pattern 1 s 1 s CAT 5 Under 1000 m TE Point to Point Expansion Point to Multipoint Point to Multipoint TE 1 TE 8 TE 8 TE 1 CAT 5 Under 150 m CAT 5 Under 500 m CAT 5 Under 50 m ...

Страница 292: ...f the cable to be connected to this optional service card is 100 m For programming instructions and other information about the IP GW4 card refer to the documentation for the IP GW4 card To confirm the trunk connection refer to Confirming the Trunk Connection in 6 12 1 Starting the Hybrid IP PBX Pin Assignments RJ45 Connector 10BASE T 100BASE TX Signal Name Input I Output O Function TPO O Transmit...

Страница 293: ...dication ON On line mode OFF Off line mode Flashing Maintenance mode Note If the LINK indicator is OFF the ONLINE indicator will also be OFF ALARM Red Alarm indication ON Alarm OFF Normal LINK Green Link status indication ON Normal Connection OFF Connection Error DATA Green Data transmission indication ON Data transmitting OFF No data transmitted ...

Страница 294: ...Accessory and User supplied Items Accessory included Extension Bolt 1 Strap 1 User supplied not included RJ45 connector or RJ11 connector Notice The connector type may be RJ45 or RJ11 depending on the country area Note For details about connecting the CS refer to 6 8 7 Connecting a Cell Station to the Hybrid IP PBX Pin Assignments RJ45 Connector Signal Name Function D1 Data port High D2 Data port ...

Страница 295: ...6 4 Installation of the Extension Cards KX TDA30 Installation Manual 295 RJ11 Connector Signal Name Function D1 Data port High D2 Data port Low Reserved 4 1 D2 D1 ...

Страница 296: ...tems Accessory included Extension Bolt 1 Strap 1 User supplied not included RJ45 connector or RJ11 connector Notice The connector type may be RJ45 or RJ11 depending on the country area Pin Assignments RJ45 Connector RJ11 Connector Signal Name Function T Tip R Ring Reserved Signal Name Function T Tip R Ring Reserved To extension RJ45 9 16 1 8 R T R T 4 1 R T ...

Страница 297: ...uded Extension Bolt 1 Strap 1 User supplied not included RJ45 connector or RJ11 connector Notice The connector type may be RJ45 or RJ11 depending on the country area Note For details about connecting the CS refer to 6 8 7 Connecting a Cell Station to the Hybrid IP PBX Pin Assignments RJ45 Connector Signal Name Function D1 Data port High D2 Data port Low Reserved To extension RJ45 9 16 1 8 D2 D1 D2...

Страница 298: ...6 4 Installation of the Extension Cards KX TDA30 298 Installation Manual RJ11 Connector Signal Name Function D1 Data port High D2 Data port Low Reserved 4 1 D2 D1 ...

Страница 299: ...sory included Extension Bolt 1 Strap 1 User supplied not included RJ45 connector or RJ11 connector Notice The connector type may be RJ45 or RJ11 depending on the country area Pin Assignments RJ45 Connector RJ11 Connector Signal Name Function T Tip R Ring Reserved Signal Name Function T Tip R Ring Reserved To extension RJ45 9 16 1 8 R T R T 25 32 17 24 R T R T 4 1 R T ...

Страница 300: ... type may be RJ45 or RJ11 depending on the country area Shown above is a card having the RJ45 connectors Note For details about connection to doorphones and door openers refer to 6 9 1 Connection of Doorphones and Door Openers Accessory included Extension Bolt 1 Strap 1 8 pin terminal block 1 10 pin terminal block 1 Telephone Line Cord 2 Terminal Box 1 for DPH4 card with RJ45 connectors or 2 for D...

Страница 301: ... Doorphone 3 transmit com3 Doorphone 3 receive com4 Doorphone 4 receive Reserved Signal Name Function DP2 Doorphone 2 transmit DP1 Doorphone 1 transmit com1 Doorphone 1 receive com2 Doorphone 2 receive DP4 Doorphone 4 transmit DP3 Doorphone 3 transmit com3 Doorphone 3 receive com4 Doorphone 4 receive Signal Name Function Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved 1 8 D...

Страница 302: ...al 10 pin Terminal Block Signal Name Function OP1b Door opener 1 OP1a Door opener 1 com OP2b Door opener 2 OP2a Door opener 2 com OP3b Door opener 3 OP3a Door opener 3 com OP4b Door opener 4 OP4a Door opener 4 com Reserved 1 10 OP1b OP1a OP2b OP2a OP3b OP3a OP4b OP4a ...

Страница 303: ...nd User supplied Items User supplied not included Copper wire Note For details about connection to doorphones and door openers refer to 6 9 1 Connection of Doorphones and Door Openers Accessory included Extension Bolt 1 Strap 1 8 pin terminal block 1 10 pin terminal block 1 Telephone Line Cord 2 Terminal Box 1 To doorphones door openers 8 pin 10 pin RJ45 Telephone Line Cord ...

Страница 304: ...l button com DC1b Doorphone control 1 DC1a Doorphone control 1 com OP2b Door opener 2 OP2a Door opener 2 com Path_2b Doorphone 2 transmit Path_2a Doorphone 2 receive Call_2b Doorphone 2 call button Call_2a Doorphone 2 call button com DC2b Doorphone control 2 DC2a Doorphone control 2 com Signal Name Function Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved 1 8 9 16 OP1b OP1a ...

Страница 305: ...6 5 Installation of the Other Cards KX TDA30 Installation Manual 305 10 pin Terminal Block Signal Name Function Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved 1 10 ...

Страница 306: ...ng conferences Accessory and User supplied Items Accessory included Extension Bolt 1 Screw 1 User supplied not included none Note To establish a conference call involving 6 to 8 parties install an ECHO8 card and enable the echo cancellation for conference using the KX TDA30 Maintenance Console refer to 7 3 3 Hybrid IP PBX Configuration ...

Страница 307: ...tion of the Other Cards KX TDA30 Installation Manual 307 6 5 4 MSG2 Card Function 2 channel message card Accessory and User supplied Items Accessory included Extension Bolt 1 Screw 1 User supplied not included none ...

Страница 308: ...Other Cards KX TDA30 308 Installation Manual 6 5 5 EXT CID Card Function Sends Caller ID signals to extension ports Accessory and User supplied Items Accessory included Extension Bolt 1 Screw 1 User supplied not included none ...

Страница 309: ...ble the number of DPTs using Digital XDP connection To be installed in the MEC slot Accessory and User supplied Items Accessory included none User supplied not included none CAUTION Make sure to insert the MEC card between the guide rails until it locks into the MEC slot Push the card firmly into place until you hear a clicking sound MEC Card MEC Slot ...

Страница 310: ...6 5 Installation of the Other Cards KX TDA30 310 Installation Manual Removing the MEC Card Pull open the guide rails using a flathead screwdriver and while holding them open remove the MEC card ...

Страница 311: ...n with the Hybrid IP PBX V90 support To be installed in the RMT slot Accessory and User supplied Items Accessory included none User supplied not included none CAUTION Make sure to insert the RMT card between the guide rails until it locks into the RMT slot Push the card firmly into place until you hear a clicking sound RMT Slot RMT Card ...

Страница 312: ...6 5 Installation of the Other Cards KX TDA30 312 Installation Manual Removing the RMT Card Pull open the guide rails using a flathead screwdriver and while holding them open remove the RMT card ...

Страница 313: ...d SLC4 SLC8 Cards DLC4 DLC8 Cards Cable Maximum Distance ø 0 4 mm Under 500 m ø 0 5 mm Under 720 m ø 0 6 mm Under 830 m CAT 5 Under 720 m Cable Maximum Distance ø 0 4 mm Under 140 m ø 0 5 mm Under 229 m ø 0 6 mm Under 360 m CAT 5 Under 229 m Cable Maximum Distance ø 0 4 mm Under 698 m ø 0 5 mm Under 1128 m ø 0 6 mm Under 1798 m CAT 5 Under 1128 m Other PT and DSS Console SLT KX T7600 Series Cable ...

Страница 314: ...an be selected through system programming If the XDP mode is enabled through system programming parallel connection is not possible Refer to 1 10 9 Parallelled Telephone and 2 1 1 Extension Port Configuration in the Feature Guide for further information Using a Modular T Adaptor To a Super Hybrid Port 4 conductor wiring cord Connect pins T R D1 and D2 2 conductor wiring cord Connect pins T and R S...

Страница 315: ...65 To a Super Hybrid Port DPT To a Super Hybrid Port To SLT 2 conductor wiring cord Connect pins T and R 4 conductor wiring cord Connect pins T R D1 and D2 SLT TO MAIN UNIT PABX TO TEL To a Super Hybrid Port DPT SLT To a Super Hybrid Port To SLT 2 conductor wiring cord Connect pins T and R 4 conductor wiring cord Connect pins T R D1 and D2 TO TEL TO EMSS or TO MAIN UNIT ...

Страница 316: ...tion is not possible Refer to 1 10 9 Parallelled Telephone and 2 1 1 Extension Port Configuration in the Feature Guide for further information With KX T7600 Series DPT except KX T7600E Series Using a Modular T Adaptor To DLC4 DLC8 card To a Super Hybrid Port for connection of SLT 4 conductor wiring cord Connect pins D1 and D2 Slave DPT SLT Master DPT Modular T Adaptor 4 conductor wiring cord Conne...

Страница 317: ...onnect pins T and R 4 conductor wiring cord Connect pins T R D1 and D2 Slave DPT Master DPT To SLT TO MAIN UNIT PABX TO TEL TO TEL TO MAIN UNIT PABX Cable Maximum Distance ø 0 4 mm Under 30 m ø 0 5 mm Under 50 m ø 0 6 mm Under 60 m CAT 5 Under 50 m Back View of DPTs To DLC4 DLC8 card To a Super Hybrid Port for connection of SLT To DLC4 DLC8 card To a Super Hybrid Port for connection of SLT ...

Страница 318: ... 4 conductor wiring cord Connect pins D1 and D2 2 conductor wiring cord Connect pins T and R Slave DPT Master DPT TO MAIN UNIT PABX TO DIGITAL TO MAIN UNIT PABX Cable Maximum Distance ø 0 4 mm Under 30 m ø 0 5 mm Under 50 m ø 0 6 mm Under 60 m CAT 5 Under 50 m Back View of DPTs To DLC4 DLC8 card To a Super Hybrid Port for connection of SLT To DLC4 DLC8 card To a Super Hybrid Port for connection of...

Страница 319: ...ring cord Connect pins T and R 4 conductor wiring cord Connect pins T R D1 and D2 Slave DPT Master DPT To SLT TO MAIN UNIT PABX TO TEL TO DIGITAL TO MAIN UNIT PABX Cable Maximum Distance ø 0 4 mm Under 30 m ø 0 5 mm Under 50 m ø 0 6 mm Under 60 m CAT 5 Under 50 m Back View of DPTs To DLC4 DLC8 card To a Super Hybrid Port for connection of SLT To DLC4 DLC8 card To a Super Hybrid Port for connection...

Страница 320: ... D2 2 conductor wiring cord Connect pins T and R 4 conductor wiring cord Connect pins T R D1 and D2 TO DIGITAL TO MAIN UNIT PABX TO TEL Back View of DPTs Cable Maximum Distance ø 0 4 mm Under 30 m ø 0 5 mm Under 50 m ø 0 6 mm Under 60 m CAT 5 Under 50 m To DLC4 DLC8 card To a Super Hybrid Port for connection of SLT To DLC4 DLC8 card To a Super Hybrid Port for connection of SLT ...

Страница 321: ...1 must be connected to the KX T7633 T7636 DPT Note The operating system of the PC required for first party call control depends on your CTI application software For details refer to the manual for your CTI application software Notes Maximum length of the USB cable is 3 m USB Modules must not be connected to DPTs in the Digital XDP connection In a Digital XDP connection the PC cannot be used If a U...

Страница 322: ...to the PS Operating Instructions RF Specification CAUTION The CS should be kept free of dust moisture high temperature more than 40 C low temperature less than 0 C vibration and should not be exposed to direct sunlight Item Description Radio Access Method Multi Carrier TDMA TDD Frequency Band 1880 MHz to 1900 MHz 1 1 The number may vary depending on the country area In Taiwan it is 1880 MHz to 189...

Страница 323: ... conversation The distance may vary depending on the environment Equipment Distance CS and office equipment such as a computer telex fax machine etc or microwaves More than 2 m CS and PS More than 1 m Each PS More than 0 5 m Hybrid IP PBX and CS More than 2 m Too many CSs in a small area can cause problems due to conflicts over which signal channels each CS can use Ideally CSs should be a minimum ...

Страница 324: ...d Install each CS temporarily as planned Notes Install at least 2 m above the floor Keep the antennas in the upright position 3 Conduct the site survey Refer to 6 7 5 Site Survey Using the KX TCA255 KX TD7590 a Test the radio signal strength using the PS Confirm that the radio signal strength level is 12 near the CS Using the KX TCA255 Using the KX TD7590 b By walking away from the CS with the PS ...

Страница 325: ...lying power b Turn off the PS 5 Connect the CS and PS to the Hybrid IP PBX and test the operation Refer to 6 7 7 Connecting a Cell Station to the Hybrid IP PBX a Connect the CSs to the Hybrid IP PBX b Register the PSs to the Hybrid IP PBX c Walk around the service area while having a conversation using a registered PS If noise is frequent or conversations disconnect relocate the CSs or install an ...

Страница 326: ...stration below shows the special transmitting patterns of radio waves 1 Radio waves are reflected by objects such as those made of metal 2 Radio waves are diffracted by objects such as metallic columns 3 Radio waves penetrate objects like those made of glass Relationships Between Radio Waves and Building Structure and Materials The CS coverage area is affected more by the building materials and th...

Страница 327: ...sistant film Radio waves are weakened considerably when they penetrate windows Floor Ferroconcrete Radio waves can penetrate them but the more iron there is the more radio waves are reflected Partition Steel Radio waves are reflected and rarely penetrate them Plywood Glass Radio waves usually penetrate them Column Ferroconcrete Radio waves can penetrate them but the more iron there is the more rad...

Страница 328: ...rmation on the map 2 Examine the service area demanded by the user on the map referring to the following example a Draw the coverage area around a CS Extend the coverage area to 30 m to 60 m in one direction depending on the materials of the building structures and obstacles in the installation site Note that a CS cannot be installed outside a building Gray Zone Conversation will be intermittent C...

Страница 329: ...ves away from a CS and there are no CSs available for handover the PS may go out of range and the call could be lost Example Installing in a Room Separated by Walls Things to take note of The room is separated by walls The room is surrounded by concrete walls CS installation plan The coverage area of each CS will not extend as much it does where there is no obstacle because the radio signals will ...

Страница 330: ...the CS Assigning the CS ID Number to the PS Using the KX TCA255 Note To clear the CS ID number assigned to the PS follow the procedure below Press 1 9 and POWER for more than 2 seconds 0 to 7 0 to 9 and A to F CS No CS ID No 1 9 9 2 ABC To enter letters A C E B D F To the initial display To the Desired CS No 3 DEF 4 GHI 0 1 5 JKL 2 ABC Press 1 9 and POWER for more than 2 seconds 0 to 7 CS No 1 9 9...

Страница 331: ...procedure below Press 1 9 and POWER for more than 5 seconds 0 to 7 0 to 9 and A to F CS No CS ID No 1 9 9 2 ABC To enter letters F1 F2 F3 INT OK A C E B D F To the initial display To the Desired CS No Press 1 9 and POWER for more than 5 seconds 0 to 7 CS No 1 9 9 3 DEF To the Desired CS No OR To clear one by one To clear all at once To the initial display ...

Страница 332: ...To see the radio signal strength of more than 1 CS a channel number must be set for each CS If more than 1 CS is in Radio Signal Test mode each CS must have a unique channel number Channel Number Switch Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 9 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 DIP Switch 1 2 3 4 5 6 OFF ON Radio...

Страница 333: ...te for users in the United Kingdom 240 V AC must not be used on a building site Instead of an AC adaptor connect a battery box to the CS 4 Install the CS temporarily for the site survey Install the CS at least 2 m above the floor keeping the antennas in the upright position To AC Adaptor KX A11 KX TCA1 Battery Box PSZZTD142CE Power Supply Adaptor PSZZ1TDA0142 Modular Telephone Cord ...

Страница 334: ...ys 0 through 9 1 Enter the Radio Signal Test mode Using the KX TCA255 Using the KX TD7590 Notes 1 Channel number 2 Slot number 3 When a slot is synchronised SYNC is displayed 4 Radio signal strength level 5 Frame error 0000 to 9999 Frame counter 0000 to 9999 Frame error indicates the number of errors out of 10 000 radio signal receptions An increased number of frame errors indicates greater radio ...

Страница 335: ...away from the CS and identify the CS coverage area within which the radio signal strength level is greater than 3 Draw the area on the map 3 Repeat the steps 1 and 2 for other CSs and relocate the CSs when necessary a Overlap adjacent CS coverage areas where the radio signal strength level is 8 by 5 m to 10 m Channel no 0 PS PS PS CH0 L 03 CH0 L 12 Radio Signal Strength Levels CH0 L 08 Out of rang...

Страница 336: ...manded by the user Notes If a channel is set the results of measurement for the 24 slots on the channel are saved each time If the same channel is set the new results override the previous ones Therefore a measurement of 10 channels 24 slots in total can be made If correct results cannot be obtained e g there are many error counters change the location of the CS and repeat the site survey to selec...

Страница 337: ...ar the scan data Using the KX TCA255 Using the KX TD7590 Press 1 9 and POWER for more than 2 seconds 0 to 9 Log No 1 9 1 Previous or Next 0 to 9 Channel No To go to other slots To go to specific channel A a Press 1 9 and POWER for more than 5 seconds 0 to 9 Log No 1 9 1 Previous or Next 0 to 9 Channel No To go to other slots To go to specific channel Press 1 9 and POWER for more than 2 seconds 1 9...

Страница 338: ...per measurement results exit the Radio Signal Test mode before connecting the CS to the Hybrid IP PBX 1 Keep pressing POWER button on the PS until the PS is turned OFF 2 Disconnect the AC adaptor or battery box from the CS and stop supplying electricity 3 Switch all DIP switches on the CS from ON to OFF 1 2 3 4 5 6 OFF ON ...

Страница 339: ... included RJ45 connector or RJ11 connector Note For details about DLC4 card or DLC8 card refer to 6 4 1 DLC4 Card or 6 4 3 DLC8 Card Signal Name Signal Name Pin No 1 2 3 4 D1 D2 D1 D2 Pin No 1 2 3 4 A Super Hybrid Port or DLC4 DLC8 card RJ11 CS RJ11 Signal Name Signal Name Pin No 1 2 3 4 D1 D2 D2 Pin No 1 2 3 4 D1 5 6 7 8 A Super Hybrid Port or DLC4 DLC8 card RJ45 CS RJ11 Cable Maximum Distance ø ...

Страница 340: ...g the CS 1 Connect the cable from a Super Hybrid Port or the DLC4 DLC8 card to the CS 2 Pass the cable through the groove of the CS in any direction depending on your preference Modular To a Super Hybrid Port or DLC4 DLC8 card To a Super Hybrid Port or DLC4 DLC8 card TO MAIN UNIT PABX ...

Страница 341: ... 3 3 PT Programming in the Feature Guide Entering the Hybrid IP PBX System Programming Mode Using a PT Administrator Level Note means default value PS Registration One PS can be registered to a maximum of 4 different Hybrid IP PBXs Using the KX TCA155 KX TCA255 1234 System Password for Administrator for PT Programming Programming No 3 digits PROGRAM PAUSE 690 001 to 028 PS No 1 to 4 digits END ENT...

Страница 342: ...em Lock Password Press POWER for 5 seconds 4 digits 4 digits ENABLE F SELECT SELECT SELECT OK OK To set system lock F DISABLE OR To register for the first time To re register Select INITIAL SETTING SELECT Select PS PROGRAM SELECT Select DECT SYS SETTING SELECT 4 digits If required OK System Lock Password Select REGISTRATION 4 digits PIN for PS Registration OK C Tone Select Setting Handset Select R...

Страница 343: ...tration will only be used when registering the PS to the Hybrid IP PBX Therefore even when there is more than 1 Hybrid IP PBX with the same PIN near the PS the PS will not be linked to a different Hybrid IP PBX during normal operation after registration Setting the PIN for Hybrid IP PBX Changing the Display Language of the PS Using the KX TCA155 KX TCA255 Using the KX TD7590 Using the KX TD7580 69...

Страница 344: ...ration below If Rejected or Time out is displayed CLEAR YES Press YES Press CLEAR 4 digits Handset PIN Select Setting Handset Select Registration Select Base 1 4 Press POWER for 2 seconds C Tone Select YES Select Cancel Base Select the desired item F 0 Select DECT SYS SETTING SELECT 4 digits If required OK System Lock Password Select CANCEL DECT SYS SELECT SELECT Select YES C Tone Press POWER for ...

Страница 345: ...tations KX TDA30 Installation Manual 345 Testing the Operation Walk around the service area while having a conversation using a registered PS If noise is frequent or conversations disconnect relocate the CSs or install an additional CS ...

Страница 346: ...e reference for wall mounting on the following page on the wall to mark the 2 screw positions 2 Install the 2 screws and washers included into the wall Notes Make sure that the screw heads are at the same distance from the wall Install the screws perpendicular to the wall 3 Hook the CS on the screw heads ...

Страница 347: ...l 347 Reference for Wall Mounting Please copy this page and use as a reference for wall mounting Note When you print out this page the distance on the paper output may deviate slightly from the measurement indicated above Install a screw here Install a screw here 71 mm ...

Страница 348: ...nt The CS should not be placed on a metal object Systems using 2 4 GHz ISM Industrial Scientific and Medical band may interfere with the KX TDA wireless system Examples of such systems are cordless telephones wireless LAN Home RF microwave ovens and other ISM devices These systems may cause minor noise Keeping some distance between the equipment listed below may prevent interference The distance m...

Страница 349: ...s planned Notes Install at least 2 m above the floor Keep the antennas in the upright position 3 Conduct the site survey Refer to 6 8 5 Site Survey a Test the radio signal strength using the PS Confirm that the radio signal strength level is 12 near the CS Using the KX TD7680 Using the KX TD7690 b By walking away from the CS with the PS check the radio signal strength The radio signal strength wea...

Страница 350: ...brid IP PBX and test the operation Refer to 6 8 7 Connecting a Cell Station to the Hybrid IP PBX a Connect the CSs to the Hybrid IP PBX b Register the PSs to the Hybrid IP PBX c Walk around the service area while having a conversation using a registered PS If noise is frequent or conversations disconnect relocate the CSs or install an additional CS 6 Mount the CS on the wall Refer to 6 8 8 Wall Mo...

Страница 351: ...lustration below shows the special transmitting patterns of radio waves 1 Radio waves are reflected by objects such as those made of metal 2 Radio waves are diffracted by objects such as metallic columns 3 Radio waves penetrate objects like those made of glass Relationships Between Radio Waves and Building Structure and Materials The CS coverage area is affected more by the building materials and ...

Страница 352: ...resistant film Radio waves are weakened considerably when they penetrate windows Floor Ferroconcrete Radio waves can penetrate them but the more iron there is the more radio waves are reflected Partition Steel Radio waves are reflected and rarely penetrate them Plywood Glass Radio waves usually penetrate them Column Ferroconcrete Radio waves can penetrate them but the more iron there is the more r...

Страница 353: ... map 2 Examine the service area demanded by the user on the map referring to the following example a Draw the coverage area around a CS Extend the coverage area to 30 m to 60 m in one direction depending on the materials of the building structures and obstacles in the installation site Note that a CS cannot be installed outside a building Gray Zone Conversation will be intermittent Coverage Area R...

Страница 354: ...t If the signal from the CS fades due to the structure of the building there may be some handover delay The user will hear a range warning before handover in this case This also applies in the case of interference from 2 4 GHz apparatus Example Installing in a Room Separated by Walls Things to take note of The room is separated by walls The room is surrounded by concrete walls CS installation plan...

Страница 355: ... CS number switches as desired Notes To see the radio signal strength of more than 1 CS a CS number must be set for each CS If more than 1 CS is in Radio Signal Test mode each CS must have a unique CS number CS Number Switch CS no 1 CS no 2 CS no 3 CS no 4 CS no 5 CS no 6 CS no 7 CS no 8 CS no 9 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 DIP Switch 1 2 3 4 5 6 OFF ON R...

Страница 356: ... an AC adaptor or battery box to the CS using a power supply adaptor 4 Install the CS temporarily for the site survey Install the CS at least 2 m above the floor keeping the antennas in the upright position To AC Adaptor KX A11 KX TCA1 Battery Box PSZZTD142CE Power Supply Adaptor PSZZ1TDA0142 Modular Telephone Cord ...

Страница 357: ...e site survey is only in English 1 Enter the Radio Signal Test mode Using the KX TD7680 Using the KX TD7690 Notes 1 CS number and radio signal strength level 2 Scan data test result number Empty memory space will be indicated by a number stored memory space will be indicated by a Display example Press 1 9 and POWER for more than 2 seconds SEARCHING CS NO 1 LEVEL 12 1 SAVE 0123456789 2 1 to 9 CS No...

Страница 358: ...ay from the CS and identify the CS coverage area within which the radio signal strength level is greater than 3 Draw the area on the map 3 Repeat the steps 1 and 2 for other CSs and relocate the CSs when necessary a Overlap adjacent CS coverage areas where the radio signal strength level is 8 by 5 m to 10 m CS no 1 PS PS PS CS NO 1 LEVEL 3 CS NO 1 LEVEL 12 Radio Signal Strength Levels CS NO 1 LEVE...

Страница 359: ...ng to the Stored Scan Data Using the KX TD7680 Using the KX TD7690 CS no 1 CS no 2 CS no 3 CS no 4 Press 1 9 and POWER for more than 2 seconds 0 to 9 Scan Data No 1 9 1 Display example When there is scan data When there is no scan data NO 1 CS No 2 LEVEL 9 NO 0 NOT SAVED To the Desired Scan Data No Press 1 9 and POWER for more than 2 seconds 0 to 9 Scan Data No 1 9 1 Display example When there is ...

Страница 360: ...the Stored Scan Data Using the KX TD7680 Using the KX TD7690 Press 1 9 and POWER for more than 2 seconds 0 to 9 or for all data Scan Data No 1 9 To the Desired Scan Data No 2 Press 1 9 and POWER for more than 2 seconds 0 to 9 or for all data Scan Data No 1 9 To the Desired Scan Data No 2 ...

Страница 361: ...oper measurement results exit the Radio Signal Test mode before connecting the CS to the Hybrid IP PBX 1 Keep pressing POWER button on the PS until the PS is turned OFF 2 Disconnect the AC adaptor or battery box from the CS and stop supplying electricity 3 Switch all DIP switches on the CS from ON to OFF 1 2 3 4 5 6 OFF ON ...

Страница 362: ...ot included RJ45 connector or RJ11 connector Note For details about DLC4 card or DLC8 card refer to 6 4 1 DLC4 Card or 6 4 3 DLC8 Card Signal Name Signal Name Pin No 1 2 3 4 D1 D2 D1 D2 Pin No 1 2 3 4 A Super Hybrid Port or DLC4 DLC8 card RJ11 CS RJ11 Signal Name Signal Name Pin No 1 2 3 4 D1 D2 D2 Pin No 1 2 3 4 D1 5 6 7 8 A Super Hybrid Port or DLC4 DLC8 card RJ45 CS RJ11 Cable Maximum Distance ...

Страница 363: ...ng the CS 1 Connect the cable from a Super Hybrid Port or the DLC4 DLC8 card to the CS 2 Pass the cable through the groove of the CS in any direction depending on your preference Modular To a Super Hybrid Port or DLC4 DLC8 card To a Super Hybrid Port or DLC4 DLC8 card TO MAIN UNIT PABX ...

Страница 364: ...ture Guide Entering the System Programming Mode PT Administrator Level PS Using the KX TD7680 PS Using the KX TD7690 Note means default value throughout this section PS Registration 1234 System Password for Administrator for PT Programming Programming No 3 digits PROGRAM PAUSE System Setting Menu Select SYSTEM SET Press POWER for 2 seconds Select PS PROGRAM 4 digits System Lock Password If require...

Страница 365: ... 4 different Hybrid IP PBXs Using the KX TD7680 Using the KX TD7690 Setting the System Lock When a system lock has been set the system lock password will be required for PS system setting Using the KX TD7680 Press POWER for 2 seconds Press S3 for 2 seconds C Tone Press S2 repeatedly to select the desired language F2 F3 Press POWER for 2 seconds Press S3 for 2 seconds C Tone Press S2 repeatedly to ...

Страница 366: ...o the Hybrid IP PBX without setting the PIN The PIN for PS registration will only be used when registering the PS to the Hybrid IP PBX Therefore even when there is more than 1 Hybrid IP PBX with the same PIN near the PS the PS will not be linked to a different Hybrid IP PBX during normal operation after registration Setting the PIN for Hybrid IP PBX Setting the PIN for PS Using the KX TD7680 Using...

Страница 367: ...X TD7690 Testing the Operation Walk around the service area while having a conversation using a registered PS If noise is frequent or conversations disconnect relocate the CSs or install an additional CS 691 001 to 028 PS No ENTER ENTER END To the PS operation below If Rejected or Time out is displayed CLEAR YES Press YES Press CLEAR Select the desired item Select DELETE SYSTEM Select YES C Tone S...

Страница 368: ...the reference for wall mounting on the following page on the wall to mark the 2 screw positions 2 Install the 2 screws and washers included into the wall Notes Make sure that the screw heads are at the same distance from the wall Install the screws perpendicular to the wall 3 Hook the CS on the screw heads ...

Страница 369: ...ual 369 Reference for Wall Mounting Please copy this page and use as a reference for wall mounting Note When you print out this page the distance on the paper output may deviate slightly from the measurement indicated above Install a screw here Install a screw here 71 mm ...

Страница 370: ...orphones German type and 2 door openers can be connected to the Hybrid IP PBX with a DPH2 card Notes KX T30865 is a Panasonic doorphone German type doorphones and door openers are user supplied Maximum Cabling Distance Current Limit for door opener 24 V DC 30 V AC 1 A maximum Installing the Doorphone KX T30865 1 Loosen the screw to separate the doorphone into 2 halves Doorphone Door Opener Cable M...

Страница 371: ... 2 screws Note Two kinds of screws are included with KX T30865 Please choose the appropriate kind for your wall type 3 Connect the wires to the screws located in the front cover 4 Re attach the 2 halves and re insert the screw when a doorphone plate has been fixed to the wall when you wish to install the doorphone directly to the wall Screw To terminal box To terminal box ...

Страница 372: ...r into the openings and levering the cover open Follow the order indicated by the numbers 1 to 4 2 Connect the wires of doorphones to the terminal box For details about pin assignments for the DPH4 card refer to 6 5 1 DPH4 Card Terminal Box included with the card DP2 Reserved com2 Reserved Reserved Reserved DP1 com1 DP4 Reserved Reserved com4 Reserved Reserved DP3 com3 To doorphones Pin Assignment...

Страница 373: ...orphones and Door Openers KX TDA30 Installation Manual 373 3 Cut and remove the appropriate parts from the cover depending on your preference 4 Make sure to run the connected wires through the opening Then close the cover ...

Страница 374: ...rphones and Door Openers KX TDA30 374 Installation Manual 5 Connect the terminal box to the DPH4 card in the Hybrid IP PBX using the telephone line cords included with the card Telephone Line Cord To DPH4 card To doorphones ...

Страница 375: ...d for pin assignments 2 Connect the wires of doorphones 1 and 3 to the red and green screws on the terminal box 3 Connect the wires of doorphones 2 and 4 to the yellow and black screws on the terminal box Panasonic Panasonic Panasonic Panasonic Yellow Red Black Telephone Line Cord Telephone Line Cord Green Doorphone 3 Doorphone 4 Doorphone 1 Doorphone 2 To DPH4 card Terminal Box included with the ...

Страница 376: ...openings and levering the cover open Follow the order indicated by the numbers 1 to 4 2 Connect the wires of door openers and doorphones to the terminal box For details about pin assignments for the DPH2 card refer to 6 5 2 DPH2 Card Terminal Box included with the card Path_1b OP1b Call_1a DC1a OP1a DC1b Path_1a Call_1b Path_2b OP2a OP2b Call_2a DC2a DC2b Path_2a Call_2b Pin Assignments for Termin...

Страница 377: ...of Doorphones and Door Openers KX TDA30 Installation Manual 377 3 Cut and remove the appropriate parts from the cover depending on your preference 4 Make sure to run the connected wires through it Then close the cover ...

Страница 378: ... and Door Openers KX TDA30 378 Installation Manual 5 Connect the terminal box to the DPH2 card in the Hybrid IP PBX using the telephone line cords included with the card To doorphones door openers Telephone Line Cord To DPH2 card ...

Страница 379: ...the card for connection 1 While pressing down on the hole at the top of the terminal block using a screwdriver insert the wire into the side hole as shown below Repeat this procedure for other door openers Refer to 6 5 1 DPH4 Card for pin assignments 2 Attach the terminal block to the connector of the DPH4 card in the Hybrid IP PBX Door Opener To door openers ...

Страница 380: ...usic Jack is an SELV port and should only be connected to an approved SELV device or in Australia via the Line Isolation Unit with the Telecommunications Compliance Label Note When the Hybrid IP PBX and external music sources are not connected to the same earth hum noise may be induced into Background Music and Music on Hold PC Printer PC BGM Music on Hold Pager Amplifier Speaker Maximum Distance ...

Страница 381: ...mming SMDR diagnostics and external system database storage save load functions Note Use an RS 232C cross cable for connection between the Hybrid IP PBX and PC Pin Assignments Connection Charts For connecting a printer PC with a 9 pin RS 232C connector No Signal Name Function Circuit Type EIA CCITT 2 RD RXD Receive Data BB 104 3 4 SD TXD ER DTR Transmit Data Data Terminal Ready BA CD 103 108 2 5 6...

Страница 382: ...all interface signals Data Set Ready DSR input An ON condition of circuit DR DSR indicates the printer or the PC is ready Circuit DR DSR ON does not indicate that communication has been established with the printer or the PC Request To Send RTS output This lead is held ON whenever DR DSR is ON Clear To Send CTS input An ON condition of circuit CS CTS indicates that the printer or the PC is ready t...

Страница 383: ...gnostics and external system database storage save load functions The Server PC is used for connecting PCs on a LAN to provide third party call control CTI The CTI connection uses the CSTA Phase 3 or TAPI 2 1 protocol Note The operating system of the PC or Server PC required for third party call control depends on your CTI application software For details refer to the manual for your CTI applicati...

Страница 384: ...the event of power failure SLTs connected to Ports 1 and 2 of the Super Hybrid Ports on the Main Board are automatically connected to PFT ports 1 and 2 of the first LCOT2 LCOT4 card installed in the least slot number Note Even when the power returns the conversation established during power failure will be maintained Using BRI2 Card LINE 1 and LINE 2 of the BRI2 card can be used for Power Failure ...

Страница 385: ...Set all DIP switches to ON positions to use LINE 1 and LINE 2 as a PFT port LINE 1 Power Failure LINE NT1 LINE 2 Power Failure EXTN extension Signal Name Level V Function TX1 Transmit data 1 RX2 Receive data 2 RX1 Receive data 1 TX2 Transmit data 2 Reserved Signal Name Level V Function RX2 Receive data 2 TX1 Transmit data 1 TX2 Transmit data 2 RX1 Receive data 1 Reserved 1 8 TX1 RX2 RX1 TX2 RX2 TX...

Страница 386: ...id IP PBX and if you unplug the Hybrid IP PBX do not perform the following procedures to start the Hybrid IP PBX again Otherwise your programmed data is cleared To restart the Hybrid IP PBX refer to 8 1 4 Using the Reset Button The Hybrid IP PBX will continue to be powered even if the power switch is turned OFF The power supply cord is used as the main disconnect device ensure that the socket outl...

Страница 387: ...upplied with the Hybrid IP PBX must be connected to DC IN 1 If an AC adaptor is connected only to DC IN 2 the Hybrid IP PBX will not start If you need to connect an additional AC adaptor plug the DC connector of the additional AC adaptor into DC IN 2 AC Adaptor DC Connector DC IN 1 2 1 DC Connector Additional AC Adaptor DC IN 2 AC Adaptor 1 2 ...

Страница 388: ...le the RUN indicator is flashing within about 10 s return the System Initialise Switch to the NORMAL position Depending on the configuration initialisation takes about 1 min to 3 min If successfully executed the RUN indicator will stop flashing and be kept lit All data will be cleared and the Hybrid IP PBX as well as all optional service cards except for the IP GW4 card will be initialised to the ...

Страница 389: ... For safety reasons make sure to turn off the power switch before unplugging the Hybrid IP PBX To unplug follow the reverse steps to plug it in Indication Colour Description RUN Green PBX status indication OFF Power Off includes normal reset ON Power On and running on line Flashing 60 times per minute Starting up Flashing 120 times per minute Starting up or resetting with the System Initialise Swi...

Страница 390: ...6 12 Starting the Hybrid IP PBX KX TDA30 390 Installation Manual ...

Страница 391: ...Installation Manual 391 Section 7 Guide for the KX TDA30 Maintenance Console KX TDA30 Explains the installation procedure structure and basic information of the KX TDA30 Maintenance Console ...

Страница 392: ...ference for the Hybrid IP PBX To programme and administer the Hybrid IP PBX by PC you need to install the KX TDA30 Maintenance Console onto the PC This manual describes overview and installation of the KX TDA30 Maintenance Console only KX TDA30 Maintenance Console 1 1 The contents and design of the software are subject to change without notice Menu Bar Programme Menu ...

Страница 393: ...ation Manual 393 7 2 Connection KX TDA30 7 2 1 Connection Serial Interface Connection Note For pin assignments and maximum cabling distance refer to 6 10 1 Connection of Peripherals PC PC To USB Port To COM Port USB Port RS 232C Port ...

Страница 394: ...uld be disabled Error Correction is not necessary Notes Use an RS 232C straight cable for connection between the Hybrid IP PBX and external modem An AT command for initialisation enabling automatic answer etc can only be programmed by KX TDA30 Maintenance Console AT F0E0V1X1S10 30S12 50 is stored as the default value For more information about the AT command refer to the external modem s instructi...

Страница 395: ...lease inform the customer of the importance of the password and the possible dangers 2 Please maintain the secrecy of the password This will avoid unauthorised access and possible dial through fraud 3 Please change the password periodically 4 We strongly recommend that a password of 10 digits is used for maximum protection against hackers 5 If the system password is forgotten you can examine the b...

Страница 396: ...X The date and time set on the PC will be used System Password for installer for PC programming Operator extension numbers Operator extensions for all time modes day lunch break night can be assigned Flexible Numbering type to pattern 1 or pattern 2 If pattern 1 with is selected must prefix all feature numbers except access numbers when an extension user wants to use a feature Operator call and Id...

Страница 397: ...ole with the Installer Level Programmer Code Note There are 2 other Programmer Codes with limited authorisation Administrator Level default 1111 and User Level default none 4 Click Connect USB from the menu bar 5 Type the system password for installer default 1234 then click OK to log in 6 When country area data do not match a Click OK to replace the country area data of the Hybrid IP PBX Replacem...

Страница 398: ...30 Maintenance Console so that the PBX starts automatically saving the system data 2 When the PBX is initialised not all data is taken from the SD Memory Card The data for present status of extension FWD DND buttons is taken from battery backup memory in the PBX 3 The PC will not perform any shutdown operation or enter the power saving system standby mode while the KX TDA30 Maintenance Console is ...

Страница 399: ...Menu Bar File Connect Tool Utility Diagnosis File Transfer PC to PBX SD Card File Transfer PBX SD Card to PC SD Card File View and Load SD Card File Delete Message File Transfer PC to PBX Message File Transfer PBX to PC Error Log ISDN Qsig Protocol Trace CS Information PS Information System Reset Reset by the Command Window Help ...

Страница 400: ...and related PT programming refer to the on line help at each screen 1 Start the KX TDA30 Maintenance Console refer to Starting the KX TDA30 Maintenance Console and Assigning the Basic Items Quick Setup in 7 3 1 Installing and Starting the KX TDA30 Maintenance Console 2 To check the slot condition of the Hybrid IP PBX a Double click Configuration b Double click Slot 3 To check the PS status a Doubl...

Страница 401: ...elated PT programming refer to the on line help at each screen 1 Start the KX TDA 30 Maintenance Console refer to Starting the KX TDA30 Maintenance Console and Assigning the Basic Items Quick Setup in 7 3 1 Installing and Starting the KX TDA30 Maintenance Console 2 To diagnose a card Click Utility Diagnosis from the menu bar 3 a Click Status of the desired card and change its status to OUS b Click...

Страница 402: ...iles for Outgoing Messages in the PC are transferred to all MSG cards Available only when at least 1 MSG card is installed Message File Transfer PBX to PC The message files for Outgoing Messages in the MSG cards are transferred to the PC Available only when at least 1 MSG card is installed Error Log The error log is displayed for details refer to 8 1 5 Troubleshooting by Error Log ISDN Qsig Protoc...

Страница 403: ...Installation Manual 403 Section 8 Troubleshooting KX TDA30 This section provides information on the Hybrid IP PBX and telephone troubleshooting ...

Страница 404: ...d AC adaptor only Connect an additional AC adaptor Improper operation Press the Reset Button refer to 8 1 4 Using the Reset Button Noise on external paging Induced noise on the wire between the Hybrid IP PBX and the amplifier Use a shielded cable as the connection wire between the Hybrid IP PBX and amplifier A short shielded cable is recommended Distorted external music Excessive input level from ...

Страница 405: ...e for T R and the outer 2 wires are for D1 D2 D1 T R D2 D1 T R D2 Hybrid IP PBX Hybrid IP PBX Hybrid IP PBX Extension CAUSE The T R is connected to the D1 D2 SOLUTION Use the correct cord the inner 2 wires are for T R D1 T R D2 T R Extension CAUSE The T is connected to the R SOLUTION Reverse the connections of the T R D1 T R D2 T R Extension Can you dial an extension Continued on the next page No ...

Страница 406: ... PBX CAUSE Trunk is connected to the T2 T1 Trunk is connected to the T2 R1 SOLUTION Reconnect the trunk to the T1 R1 or T2 R2 of the telephone jack using 2 conductor wiring T2 R1 T1 R2 Trunk Hybrid IP PBX Hybrid IP PBX Trunk T2 R1 T1 R2 Continued from the previous page Can you dial out on a trunk No ...

Страница 407: ...switch to the other position Originating an outside call call transfer or conference cannot be performed The corresponding CO button does not exist on the PT Programme the CO button Refer to 1 19 2 Flexible Buttons in the Feature Guide Cannot register the PS Wrong Personal Identification Number PIN is registered to the PS Register the PIN set to the Hybrid IP PBX into the PS CS is not connected pr...

Страница 408: ... is out of CS coverage area Locate the CS properly refer to 6 7 5 Site Survey Using the KX TCA255 KX TD7590 or 6 8 5 Site Survey PS stays out of service when the CS status is changed from Out of Service to In Service It may take about 10 s for CS to start up after the status has been changed to In Service Wait until the CS starts up PROBLEM PROBABLE CAUSE SOLUTION ...

Страница 409: ... you must press the Reset Button with caution because all data stored in memory will be cleared by the following operation 1 pressing the Reset Button and then 2 setting the System Initialise Switch to the NORMAL position while the RUN indicator is flashing within approximately 10 s Operation 1 If the Hybrid IP PBX does not operate properly a Make sure that the System Initialise Switch is set to t...

Страница 410: ...not work a Unplug the Hybrid IP PBX b Set the System Initialise Switch to the SYSTEM INITIALIZE position c Plug in the Hybrid IP PBX after 5 min d Press the Reset Button e Set the System Initialise Switch to the NORMAL position while the RUN indicator is flashing within approximately 10 s ...

Страница 411: ...id IP PBX Maintenance Example KX TDA30 Maintenance Console Example Station Message Detail Recording SMDR Description Item Description 1 Date Date of the error detection 2 Time Time of the error detection 3 Level Major Alarm MJ ALM Errors that affect the whole system operation or result in system failure Minor Alarm MN ALM Errors that affect certain part of system operation 4 Error Code Three digit...

Страница 412: ...onal service cards YY Physical port number 01 to 16 For optional service cards that are installed in Slots 08 to 11 sub slot number port number will be displayed Sub slot 1 11 to 14 Note When there is no parameter for slot and physical port number XX and YY will be displayed as 00 Example Sub code for MPR 10000 6 Error Message Error description maximum 36 characters Item Description ...

Страница 413: ...ial Self Diagnosis System Start up and On line Operation Error Code Error Message PROBABLE CAUSE SOLUTION 212 Echo canceller access error Optional service card malfunction ECHO See if the corresponding optional service card is installed properly Pull out and re insert the corresponding optional service card Press the Reset Button Replace the corresponding optional service card 215 Framer IC access...

Страница 414: ...nnected properly Check the AC cord Replace the AC cord be sure to turn off the Hybrid IP PBX when replacing Replace the Main Board be sure to turn off the Hybrid IP PBX when replacing Remove the optional service cards and restart the Hybrid IP PBX 012 MPR RAM battery low Battery out Main Board MPR malfunction Replace the Main Board be sure to turn off the Hybrid IP PBX when replacing 013 Additiona...

Страница 415: ...n Press the Reset Button Reprogramme the Hybrid IP PBX Replace the SD Memory Card Replace the Main Board be sure to turn off the Hybrid IP PBX when replacing 021 SD Memory Card disconnected SD Memory Card not installed Bad connection of SD Memory Card SD Memory Card malfunction Main Board malfunction 022 Not enough free space on SD card Not enough memory space available to save the system data or ...

Страница 416: ...mory Card SD Memory Card malfunction Main Board malfunction Press the Reset Button Reprogramme the Hybrid IP PBX Replace the SD Memory Card Replace the Main Board be sure to turn off the Hybrid IP PBX when replacing 032 System initialization file not found 033 Card initialization file not found 034 LCD file not found 035 System data file access error 036 System initialization file access error 037...

Страница 417: ...ng optional service card is installed properly Replace the corresponding optional service card 305 Data Link failure Data link between the CS and Hybrid IP PBX failed Data link between the network and BRI IP GW card failed Check the connection between the CS and Hybrid IP PBX Check the connection between the network and BRI IP GW card 307 LAN No Carrier IP GW card not connected to the LAN Check th...

Страница 418: ... GW is stopped from a remote maintenance PC This information is logged when IP GW is stopped from a remote maintenance PC 370 IP GW Rebooted by Maintenance Console IP GW is rebooted from a remote maintenance PC This information is logged when IP GW is rebooted from a remote maintenance PC 371 IP GW Rebooted Optional service card malfunction IP GW Check whether the software version of the IP GW car...

Страница 419: ...ekeeper is recovered This information is logged when connection to the Gatekeeper is recovered 396 IP GW Run IP GW is started from a remote maintenance PC This information is logged when IP GW is started from a remote maintenance PC 510 SMDR disconnect RS 232C cable not connected Breaking of RS 232C cable Printer terminal equipment malfunction Check the RS 232C cable Check the terminal equipment E...

Страница 420: ...8 1 Troubleshooting KX TDA30 420 Installation Manual ...

Страница 421: ...Installation Manual 421 Index ...

Страница 422: ...ion Card KX TDA3174 241 299 A About the Other Manuals 11 AC Adaptor Capability 247 AC Adaptor Selection 247 Additional AC Adaptor KX A236 242 After Site Survey 152 178 338 361 Amphenol Connector Pin Assignment Chart 58 Attaching a Ferrite Core 55 B Backup Batteries Connection 47 259 Basic Shelf 24 Basic System Construction KX TDA100 KX TDA200 24 Basic System Construction KX TDA30 238 Before Instal...

Страница 423: ... Type Power Supply Unit 29 42 KX TDA0144 4 Cell Station Interface Card 27 104 KX TDA0144 8 Cell Station Interface Card 27 104 KX TDA0161 4 Port Doorphone Card 27 118 KX TDA0162 2 Port Doorphone Card German Type 27 120 KX TDA0166 16 Channel Echo Canceller Card 27 123 KX TDA0170 8 Port Digital Hybrid Extension Card 27 106 KX TDA0171 8 Port Digital Extension Card 27 109 KX TDA0172 16 Port Digital Ext...

Страница 424: ...8 Remote Card KX TDA0196 28 72 Remote Card KX TDA3196 242 311 Removing Attaching the Front Cover 255 RF Specification 136 322 RMT Card 72 311 S Safety Installation Instructions 36 250 Safety Instructions 42 SAFETY REQUIREMENTS 6 SD Memory Card 69 257 Site Planning 140 168 326 351 Site Survey 174 357 Site Survey Using the KX TCA255 KX TD7590 148 334 SLC16 and MSLC16 Cards 115 SLC4 Card 296 SLC8 Car...

Страница 425: ...vice Port 129 315 Using the Reset Button 223 409 V Voice Mail Features 22 236 W Wall Mounting AC Adaptor 275 Wall Mounting CS 162 187 346 368 Wall Mounting KX TDA100 61 Wall Mounting KX TDA200 59 Wall Mounting KX TDA30 272 Wiring Precautions 36 250 ...

Страница 426: ...Index 426 Installation Manual ...

Страница 427: ...250 mm 240 mm 65 mm 130 mm 120 mm Reference for Wall Mounting Install a screw here Install a screw here Install a screw here ...

Страница 428: ...ted by Panasonic Communications Co Ltd PCC You may print out this manual solely for internal use with this model Except above you may not reproduce this manual in any form in whole or part without the prior written consent of PCC 2003 Panasonic Communications Co Ltd All Rights Reserved PSQX2633WA KK0103AH3034 Version 0 02 ...

Отзывы: