![Panasonic HIT Double Photovoltaic modules Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/panasonic/hit-double-photovoltaic-modules/hit-double-photovoltaic-modules_general-installation-manual_278223006.webp)
General Installation Manual
© Apr 2012, SANYO Electric Co., Ltd. All Rights Reserved
6
Bolt (Stainless steel)
#8, #10, M5.
Length
(not less than 1.024”(26 mm)
not more than 1.26”(32 mm))
Ground wire (#12AWG)
(wound around the bolt)
Cup washer (Terminal cup)
(Stainless steel or *brass)
Flat washer (Stainless steel)
Spring washer (Stainless steel)
Grounding hole
(0.205” diameter
(5.2 mm))
Star washer (Stainless steel)
Flat washer (Stainless steel)
Frame (Shorter side)
Nut (Stainless steel)
Glass
Figure 4.1
Grounding method using cup washer
*Flat washer (Stainless steel)
*
If using a brass cup washer, a flat washer must be inserted between the cup washer and module frame, and the flat
washer diameter must be greater than the cup washer diameter.
Glass
Figure 3-1. Configuration of Junction Box for VBHBxxxDA03
negative ( - )
positive ( + )
Connector
MC
TM
Plug
Connector
MC
TM
Plug
Cable
Cable