FUNCTION SETTINGS
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
5-63
5-3-7 Scaling Upper Limit Value / Scaling Lower Limit Value (
/
)
When analog scaling is set to “FREE”, you can set the upper limit value and lower limit value of
scaling.
●
When scaling lower limit value < scaling upper limit value
20mA
4mA
Judgment value (JUDGE.V)
Analog current output
Lower limit value
(0.5mm)
Upper limit value
(5mm)
●
When scaling lower limit value > scaling upper limit value
20mA
4mA
Upper limit value
(0.5mm)
Lower limit value
(5mm)
Analog current output
Judgment value (JUDGE.V)
●
When scaling lower limit value = scaling upper limit value
20mA
4mA
Lower limit value = Upper limit value
(5mm)
Outputs 4mA.
Analog current output
Judgment value (JUDGE.V)