![Panasonic HG-F13A-A-N Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/panasonic/hg-f13a-a-n/hg-f13a-a-n_installation-instructions_3813957002.webp)
1.
After turning on the power supply, make sure that the following measurement dis-
play is displayed and then press and hold the UP key for three seconds or longer.
The display changes to the
Emitted beam spot check mode
.
Hold down for 3 seconds
<Measurement display> < Emitted beam spot check mode display>
2.
Spot beam is emitted from this product in a one second cycle. Check the spot
beam and adjust the beam axis while moving the sensor.
Spot beam
●
When the
Emitted beam spot check mode
is used, sensing objects cannot be measured.
●
By holding down the UP key for three seconds or longer while the
Emitted beam
spot check mode
is used, you can deactivate the
Emitted beam spot check mode
.
●
The display automatically returns to the measurement display when two minutes
elapses after the sensor is set to the
Emitted beam spot check mode
. Press
and hold the UP key for three seconds or longer again to continuously adjust the
beam axis to set to the
Emitted beam spot check mode
.
7
LIST OF SETTING ITEMS
●
The items that can be set with this product are as follows. For various setting methods, refer to the
HG-F1
Series User’s Manual (our website: https://industrial.panasonic.com/ac/e/dl_center/manual/ ).
Item
Function
Emitted beam spot check mode In this mode, you can readily check if laser spot beams are applied to the workpiece.
Teaching
This function is used to set a threshold value. You can select the teaching method in
the PRO mode sensing output setting.
Peak / bottom hold function
This function is used to display the peak value or bottom value in a certain period.
Zero setting
This function is used to force the current measured value to “zero” (reference value).
Key lock
This function is used to disable function key operation.
PRO mode
Response time setting
This setting is used to select the time from when the sensing state changes to when
the control output changes.
Output operation setting
This setting is used to set the control output state for the light-ON state or the dark-ON state.
Sensing output setting
This setting is used to select the operation mode for control output from the normal
sensing mode and the window comparator mode.
Analog output setting
This setting is used to select analog output from voltage output and current output.
Analog scaling
Set optional two points at the upper limit and the lower limit to perform two-point
correction before data is output in analog form.
Hysteresis setting
Set the hysteresis value.
Shift amount setting
Set a shift amount for performing teaching.
External input setting
This setting is used to select the external input operation from zero setting, teaching,
and beam emission stop.
Timer setting
This setting is used to select the timer operation from off delay, on delay, and one shot.
Timer time setting
Set the timer time.
Hold setting
Set the digital display, the control output, and the analog output operation when a
measurement error occurs.
ECO setting
The digital display can be set to go OFF when key operation is not performed for 30 seconds.
Reset setting
Setting is reset to the factory default state (initial value).
8
INSPECTION METHOD
Inspect the sensor regularly to maintain performance and enable optimum use.
The main inspection items are as follows:
●
Has any fastener for this product become loose?
● Have any input and output terminals become loose or come off?
●
Is there any crack in the cable?
● Is there any discrepancy in position between the beam spot and the specified place?
●
Is the supplied power within the rated voltage range (24 V DC ±10 %)?
● Is the operating ambient temperature within the specified range (-10 to +45 °C)?
● Is the operating ambient humidity within the specified range (35 to 85 % RH)?
●
Are the light emitting and receiving windows of this product contaminated with
dirt or foreign matter?
9
ERROR DISPLAY
●
In case of errors, take the following measures.
Error code
Description
Remedy
Er01
Abnormal, damaged, or end-of-life
internal memory
• Turn the power OFF and then ON, and enable the reset
setting in setting items (initialization of this product).
• If the sensor does not recover even after the above
action is taken, consult your Panasonic representative.
Er11
Control output load has short-circuited
and excessive current is flowing.
Turn OFF the power and check the load.
Er31
When the zero setting is enabled, the
measurement is not performed normally.
Check if the sensing distance to be set is within the speci-
fication range.
Er41
During teaching, the measurement is not
performed normally.
Check if the sensing distance to be set is within the spec-
ification range.
Er51
Abnormality in the beam emitting window
or beam receiving window
Turn the power OFF and then ON. If the sensor does not
recover even after being turned back on, consult your
Panasonic representative.
Er90
System error
The product could be faulty.
Please consult your Panasonic representative.
Er91
Er92
Er93
Er94
Er95
Er96
4
BEFORE USING THIS PRODUCT
Contents of Package
Sensor
1 pc.
FDA certificate / identification label
1 pc.
Installation Instructions Manual (English / Japanese, Chinese / Korean) 1 pc.each
General Information for Safety, Compliance, and Instructions
1 pc.
Optional Items
●
Simple mounting bracket
MS-HG-01
(optional)
Surrounding Environment
●
Operating ambient temperature: -10 to +45 °C (No icing allowed)
●
Operating ambient humidity: 35 to 85 % RH (No dew condensation allowed)
●
Operating ambient illuminance: Incandescent lamp: Light receiving surface illumi-
nance of 3,000 ℓx or less
●
Operating altitude: 2,000 m or less (Note)
●
Degree of pollution: 2
Note: Do not use or store this product in environments where ambient air is pressurized to an air
pressure higher than the atmospheric pressure at an altitude of 0 m.
5
DESCRIPTION OF PARTS
1
2
3
4
1
2
3
4
5
6
7
8
9
Name
1
Digital display (Red)
2
PRO indicator (Yellow)
3
Zero set indicator (Yellow)
4
Teaching indicator (Yellow)
5
Output operation indicator (Orange)
6
Laser emission indicator (Green)
7
TEACH key
8
UP key
9
DOWN key
Name
1
Beam emitting part (laser opening)
2
Beam receiving part
3
Mounting hole
4
Operation and display section
■ Sensor Unit
■ Operation and Display Section
6
MOUNTING AND WIRING
Mounting Method
●
When mounting this product, use M3 screws (prepare separately).
Use a tightening torque of 0.5 N∙m or less for mounting.
M3 (Length: 25 mm)
Screw with washer
(Mounting hole spacing)
18 mm
37 mm
●
When using multiple sensors, mount them so that emitted laser spot beams do
not directly enter the beam receiving parts of sensors other than the beam-emit-
ting sensor to avoid mutual interference. Also, mount them so that spot beams
projected onto the workpiece do not overlap with the spot beams of other sensors.
●
Do not mount the sensors closely side by side to prevent the temperature of the
sensors from rising to more than the specified point due to heat generation.
●
To prevent screws from loosening and falling, take a measure to prevent loos-
ening of screws, such as use of screw and washer assemblies, depending on
usage conditions.
●
Use the tightening torque of 0.5 N·m or less even when using the simple mount-
ing bracket
MS-HG-01
(optional).
Simple mounting bracket
MS-HG-01
(Optional)
Plate bracket
(Supplied with the
MS-HG-01
)
M3 (Length: 25 mm)
Screw with washer
(Supplied with the
MS-HG-01
)
Wiring Method
<When using the NPN output type>
HG-F13A-A-N
Analog
input device
24 V DC
±10 %
(Brown) +V
(Pink) External input
(Black) Control output
(Blue) 0 V
(Gray) Analog output
(Shield) Analog ground
External
input
+
-
Load
<When using the PNP output type>
HG-F13A-A-P
+
-
Analog
input device
24 V DC
±10 %
(Brown) +V
(Pink) External input
(Black) Control output
(Blue) 0 V
(Gray) Analog output
(Shield) Analog ground
External
input
Load
Note: Insulate unused terminals to avoid error input or short circuit.
How to Check Emitted Beam Spot
●
This product provides the
Emitted beam spot check mode
in which the place
irradiated with laser spot beams can be checked readily. When the product is in
this mode, the spot beam is brighter and flashed.
Follow the procedure below to set to the
Emitted beam spot check mode
and
adjust the workpiece position.
Panasonic Industry Co., Ltd.
Panasonic Industrial Devices SUNX Co., Ltd.
https://panasonic.net/id/pidsx/global
Please visit our website for inquiries and about our sales network.
Panasonic Industrial Devices SUNX Co., Ltd. 2022
September, 2022
PRINTED IN JAPAN