Panasonic HG-C1000L Series Скачать руководство пользователя страница 5

5

10

Peak / bottom hold function

The peak / bottom hold function is for displaying the peak value and the bot-

tom value. 

When the zero set function is executed while the peak / bottom hold func

-

tion is set to “Peak hold” or “Bottom hold”, the held measured value will be 

reset.

Press the TEACH 

key and UP key 

simultaneously for 3 

seconds.

Press the 

UP/DOWN key

Press the 

TEACH key

Confirmed

Select

or

or

or

(automatically 

set after 3 

seconds.)

Digital 

display

Description

Function

Hold function release

Releases the hold status, and outputs 

the current measured value

Peak hold

Holds maximum measured value

Bottom hold

Holds minimum measured value

11

Zero set function

The zero set function is the function to compulsory set the measured value 

to ‘zero’. 

The zero set indicator (yellow) will turn ON when the zero set is valid.

When the display setting is set to Offset, the zero set function cannot be 

set.

“Zero set” setting

Confirmed

Press the UP and 

DOWN key 

simultaneously for 3 

seconds.

Zero set release

Automatic

will be displayed 

during this period.

Press the UP and 

DOWN key 

simultaneously for 6 

seconds.

12

Key lock function

The key lock function is to prevent acceptance of key operations, so that 

the conditions in each setting mode are not changed accidentally.
When the key operation is performed after the key lock is set, 

 

 ”

 will be 

displayed on the digital display.

Key lock setting

Press the TEACH 

key and DOWN key 

simultaneously for 3 

seconds.

Automatic

Key lock release

Press the TEACH 

key and DOWN key 

simultaneously for 3 

seconds.

Automatic

13

PRO mode setting

Part description

1

2

3

4

No.

Item

1

PRO indicator (Yellow)

2

DOWN key (Select)

3

UP key (Select)

4

TEACH key (Confirmed)

Arrow description in figures

Arrow

Description

Press the TEACH key
Press UP key or DOWN key
Press DOWN key

Press the DOWN key for 3 seconds or more to switch to PRO MODE. The 

PRO indicator (yellow) will turn ON when the PRO MODE is active. To re-

turn to the measurement display, press the DOWN key again for 3 seconds 

or more.

Содержание HG-C1000L Series

Страница 1: ...ER RADIATION LASER APERTURE CLASS2 LASER PRODUCT IEC60825 1 2007 MAXIMUM OUTPUT 1mW PULSE DURATION 5ms max WAVELENGTH 655nm DO NOT STARE INTO BEAM An English warning label is attached to this product 4 Part description 5 6 7 8 9 1 2 3 4 No Item 1 Zero set indicator Yellow Lights when the zero set function is enabled 2 Teaching indicator Yellow Lights when teaching is in process 3 Output operation ...

Страница 2: ...tom hold function Setting Index84 Release Index2 Zero set function Save in nonvolatile memory Index2 Execute Index2 Release of nonvolatile memory Index2 Key lock function Setting Release Index12 Response Speed Setting 10ms 5ms 1 5ms Index66 Output operation setting Light ON Dark ON Index61_1 Hysteresis setting Hysteresis value Index61_3 Shift setting Mode Index74_1 Shift amount setting Shift amoun...

Страница 3: ... a 1 point teaching This mode is used for sensing within the threshold range When performing the 1 point teaching window comparator mode preset Window comparator mode 1 in the sensing output setting of the PRO mode For the setting method refer to section 13 PRO mode setting ON OFF OFF Sensing object Threshold 2_SL Reference surface Threshold 1_SL 1 Press the TEACH key twice when the sensing object...

Страница 4: ...nges in the measured values and to only detect sudden changes To use the Rising differential mode or Trailing differential mode preset Ris ing differential mode oder Trailing differential mode in the sensing output setting of the PRO mode For the setting method refer to section 13 PRO mode setting The threshold can be set by using the threshold value fine adjustment func tion see section 9 Thresho...

Страница 5: ...set setting Confirmed Press the UP and DOWN key simultaneously for 3 seconds Zero set release Automatic will be displayed during this period Press the UP and DOWN key simultaneously for 6 seconds 12 Key lock function The key lock function is to prevent acceptance of key operations so that the conditions in each setting mode are not changed accidentally When the key operation is performed after the...

Страница 6: ...ms 50ms 100ms 250ms 500ms 1 000ms 5 000ms Display The display of the measured value can be changed Normal Invert Offset Hold Set the control output and the analogue output operation when a measurement error occurs insufficient light intensity saturation of light intensity out of measurement range Hold OFF Hold ON ECO The digital display can be set to go OFF when key operation is not performed for ...

Страница 7: ...ulator ensure that the frame ground F G terminal of the power supply is connected to an actual ground If noise generating devices switching regulators inverter motors etc are used around the sensor mounting area make sure to connect the frame ground FG terminal of the device Do not use this product during the transient state when the power sup ply is turned ON The overall length of the cable can b...

Страница 8: ...urce current Leakage current max 0 1mA Output operation Selectable either Light ON or Dark ON Short circuit protection Incorporated auto reset Response time Switchable between high speed 1 5ms standard 5ms and high precision 10ms IO Link communication IO Link specification Ver1 1 Baud rate COM3 230 4kbps Process data length 4byte Degree of protection IP67 IEC Degree of pollution 2 Ambient temperat...

Отзывы: