background image

file:///C|/U

.../Temp/Rar$EXa0.980/viewing/SGML_VIEW_DATA/ALL/H-PS45175PP/SVC/DSC1109054CE/doc/DSC1109054CE_cvr.xml[11/12/2018 3:58:01 PM]

Order No.DSC1109054CE

B26

Interchangeable Lens for Digital Camera

Model No.

H-PS45175PP

H-PS45175E

H-PS45175GK

Colour
Vol.1
(K)...............Black Type
(S)...............Silver Type

Содержание H-PS45175E

Страница 1: ..._VIEW_DATA ALL H PS45175PP SVC DSC1109054CE doc DSC1109054CE_cvr xml 11 12 2018 3 58 01 PM Order No DSC1109054CE B26 Interchangeable Lens for Digital Camera Model No H PS45175PP H PS45175E H PS45175GK Colour Vol 1 K Black Type S Silver Type ...

Страница 2: ... Temp Rar EXa0 980 viewing SGML_VIEW_DATA ALL H PS45175PP SVC DSC1109054CE doc DSC1109054CE_cvr xml 11 12 2018 3 58 01 PM Panasonic Corporation 2011 Unauthorized copying and distribution is a violation of law ...

Страница 3: ...ill be followed by supplement service manual 1 2 Important Notice 1 2 1 About LENS MAIN BLOCK UNIT Ref 212 1 This Service Manual does not contain the repair service information for LENS MAIN BLOCK UNIT Ref 212 because it requires special facilities and equipment 2 The LENS MAIN BLOCK UNIT Ref 212 performance must be confrmed 3 In case of the LENS MAIN BLOCK UNIT Ref 212 defects contact to the serv...

Страница 4: ... U l Temp Rar EXa0 980 viewing SGML_VIEW_DATA ALL H PS45175PP SVC DSC1109054CE doc DSC1109054CE_02 xml 11 12 2018 3 59 44 PM 2 Operating Guide 2 1 Before Use Information for Your Safety 2 2 Cautions For Use ...

Страница 5: ...9 44 PM 2 3 Components Note Change in the image by the focus operation may be more visible depending on the recording condition when the AF operates during the motion picture recording It is recommended to fx the focus by setting the camera to manual focus MF etc when the change of image is disturbing you 2 3 1 Accessories ...

Страница 6: ...file C U l Temp Rar EXa0 980 viewing SGML_VIEW_DATA ALL H PS45175PP SVC DSC1109054CE doc DSC1109054CE_02 xml 11 12 2018 3 59 44 PM 2 3 2 Attaching Detaching the Lens ...

Страница 7: ...re and Tools are used for Checking Servicing for this unit 3 2 Clean Box The repair quality is considered and it is recommended working in the environment of satisfed clean level less than class 10 000 Federal Standard 209D When remove the 1st lens frame it is indispensable NOTE Work in the environment of satisfed clean level less than class 10 000 Federal Standard 209D when remove the 1st lens fr...

Страница 8: ...ce manual for details 2 To minimize the possibilities risk of getting the dust dirt on the lens surface keep covering the lens unit with Lens caps front rear other than necessary cases 3 Do not touch the surface of the lens glasses with your fngers 4 Blow off the dust on the surface of the lens with a blower brush 5 Use lens cleaning KIT BK VFK1900BK NOTE 1 When tightening screws use a Torque driv...

Страница 9: ...054CE doc DSC1109054CE_04 xml 11 12 2018 4 02 41 PM 4 2 Disassembly Procedure 1 Remove the 3 screws showed in the following picture then remove SHADING FLAME UNIT B201 B202 B203 2 Remove the 4 screws showed in the following picture then remove L MOUNT UNIT B204 B205 B206 and B207 ...

Страница 10: ... 2018 4 02 41 PM 3 Remove MOUNT SPACER 4 Remove the 3 screws and 1 fex showed in the following picture then remove REAR FRAME UNIT and DUST PROOF RING B209 B210 B211 5 Remove the 5 fexes showed in the following picture then remove LENS PCB UNIT and MOUNT CONTACT UNIT 4 FLOATING RUBBER is attached on LENS PCB UNIT ...

Страница 11: ...n the following picture then remove MOUNT CONTACT UNIT from LENS PCB UNIT 4 3 Assembly Procedure 1 Insert the fex of MOUNT CONTACT UNIT into the connector of LENS PCB UNIT 2 Set LENS PCB UNIT on the LENS Body then Insert the 5 fexes into the connector of LENS PCB UNIT 3 Attach REAR FRAME UNIT on the LENS Body to set the mark of the two in the same direction ...

Страница 12: ...ml 11 12 2018 4 02 41 PM 4 Insert the fex of ZOOM SW UNIT into the connector of LENS PCB UNIT then set DUST PROOF RING in the REAR FRAME UNIT 5 Tighten the 3 screws in the order as shown in the fgure by using the torque driver with specifed torque Torque 7 1N cm 6 Insert the Mount Spacer into the Lens Body ...

Страница 13: ...into place 8 Set SHADING FLAME UNIT on L MOUNT UNIT then tighten the 3 screws in the order as shown in the fgure by using the torque driver with specifed torque Torque 10 1 2N cm 9 Tighten 3 screws in the order as shown in the fgure by using the torque driver with specifed torque then tighten a screw connecting L MOUNT UNIT and MOUNT CONTACT UNIT in the same way Torque B204 to B206 20 1 2N cm B207...

Страница 14: ...file C U l Temp Rar EXa0 980 viewing SGML_VIEW_DATA ALL H PS45175PP SVC DSC1109054CE doc DSC1109054CE_04 xml 11 12 2018 4 02 41 PM ...

Страница 15: ...the dust and or dirt gets on the outer side surface of the Lens glasses order the following procedures 1 Blow off the dust on the Lens glass surface with the Blower gently Do not Blow too strongly 2 Wipe out the dirt on the lens glass surface with Lens cleaning KIT VFK1900BK if necessary Consult the Instruction sheet which is included in the Lens cleaning KIT in details NOTE About rear side of len...

Страница 16: ...lens frame unit which was ftted as it was Therefore the 1st lens frame unit is not supplied as spare parts Also do not exchange the 1st lens unit taking from others 5 2 1 Disassembly procedure Important It must be performed inside of satisfed clean level Satisfed clean level Less than class 10 000 Federal Standard 209D 1 DECO RING 1 Decoration ring is sticked on the 1st lens frame unit 2 Put the s...

Страница 17: ...T B212 B214 Black 4mm 4 Removal of dusts dirt 1 Blow off the dust on the surface of the lens with a blower brush 2 Use lens cleaning KIT BK VFK1900BK if necessary 5 2 2 Assembly procedure Important When tightening the screw use a torque driver RFKZ0456 by ordering the screwing order with specifed torque described in each step 1 Set 1ST LENS FRAME UNIT on 2ND LENS FRAME UNIT with positioning the 3 ...

Страница 18: ...the 3 screws by using the torque driver with specifed torque Torque 7 1 2N cm 3 Attach FILTER RING UNIT on the Lens Body to set the mark of the two in the same direction 4 Tighten the 3 screws in the order as shown in the fgure by using the torque driver with specifed torque Torque 10 1 2N cm 5 Install DECO RING by referring the Phase marks ...

Страница 19: ... SVC DSC1109054CE doc DSC1109054CE_05 xml 11 12 2018 4 04 07 PM Use new one Do not use the one which is removed After installing the DECO RING press it with your fnger Ref The character LUMIX G of the DECO RING is near the mark at the side surface of FILTER RING UNIT ...

Страница 20: ...AppData Local Temp Rar EXa0 980 viewing SGML_VIEW_DATA ALL H PS45175PP SVC DSC1109054CE doc DSC1109054CE_06 xml 11 12 2018 4 04 40 PM 6 Exploded View 6 1 Frame Casing Section 6 2 Packing Parts and Accessories Section ...

Страница 21: ...file C U etabi AppData Local Temp Rar EXa0 980 viewing SGML_VIEW_DATA ALL H PS45175PP SVC DSC1109054CE doc DSC1109054CE_06 xml 11 12 2018 4 04 40 PM ...

Страница 22: ... VGQ0X18 SILVER RING 1 203 VMG2001 ZOOM RUBBER RING 1 204 VMG1847 DUST PROOF RING 1 205 VMG1855 FLOATING RUBBER 1 206 VMG1855 FLOATING RUBBER 1 207 VMG1855 FLOATING RUBBER 1 208 VMG1855 FLOATING RUBBER 1 209 VXQ2108 L MOUNT UNIT 1 210 VEJ2306 MOUNT CONTACT UNIT 1 211 VDW2276 SHADING FRAME 1 212 LENS MAIN BLOCK UNIT 1 Not Supplied B201 VHD2246 SCREW 1 B202 VHD2246 SCREW 1 B203 VHD2246 SCREW 1 B204 ...

Страница 23: ... LENS STORAGE BAG 1 104 VYC1066 LENS HOOD UNIT 1 105 VQT3R89 OPERATING INSTRUCTIONS ENGLISH CANADIAN FRENCH SPANISH 1 PP 105 VQT3R90 OPERATINGINSTRUCTIONS ENGLISH GERMAN FRENCH SPANISH ITALIAN CHINESE TRADITIONAL RUSSIAN 1 E 105 VQT3R91 OPERATING INSTRUCTIONS CHINESE SIMPLIFIED 1 GK 106 VQL2N81 OPERATING LABEL 1 PP E 107 VPF1230 POLYETHYLENE COVER 1 PP E 108 VPF1439 LENS BAG 1 109 VPF1328 BAG POLY...