background image

Troubleshooting

22

If you find any problem, please take the following steps to check.

 LED

The POWER LED (Power) is not lit.

  Check if the power cord is disconnected. Please confirm that the power cord is 

securely connected to the power port.

  Is the Ethernet Switch being used at a temperature between 0 and 50

°

C?

    Use the Ethernet Switch in its operating temperature range.
    Note: If used at a temperature out of the operating temperature range, the    
       protection equipment becomes activated and Ethernet Switch power stops.

The Port LED is not lit in Status mode.

  Is the cable correctly connected to the target port?

  Is the cable appropriate to use?

  Is the terminal connected to the relevant port conforming with 10BASE-T, 

100BASE-TX, or 1000BASE-T standard?

  Auto-negotiation may have failed.

  Check the port settings of this Ethernet Switch or the terminal settings.

  Is the correct Port LED display mode selected using the LED display switch 

button?

The Port LED (left) lights in orange.

  Loop is occurring. By removing the loop, orange LED will be turned off.

LOOP HISTORY LED Blinks in green.

  This is to notify that there is a port in which a loop is occurring, or has been 

removed within 3 days.

 Communication is slow.

  Are the communication speed and mode settings correct?

  If the proper communication mode signal cannot be obtained, apply 

half-duplex mode.

  Please reconfirm auto-negotiation setting.
  Do not set forced full-duplex for the equipment that the Ethernet Switch is 

connected to.

  Is not the utilization ratio of the network to which this Ethernet Switch is 

connected too high?

  Try separating this Ethernet Switch from the network.

Содержание GA-ML24TCPoE+

Страница 1: ... customers are not covered by the warranty C0620 20222 Printed in Japan GA ML24TCPoE Model No PN262492 TH PN262492 MY PN262492 ID PN262492 SG The instruction manuals Menu Version CLI Version Web Version latest firmware and SDN application ZEQUO assist Plus can be downloaded from the following URL https panasonic co jp ew pewnw english datadownload index html 2 12 7 Higashi Shimbashi Minato ku Toky...

Страница 2: ...res 1 2 Specifications 1 3 Accessories 1 4 Basic operation 2 Part Names and Functions 2 1 LED display change 2 2 PoE power supply function 3 Installation and Configuration 3 1 Grounding Cable Connection 3 2 Mounting to rack 3 3 Configuration of IP address Basic Troubleshooting 3 7 8 8 9 11 11 12 15 17 18 18 19 20 22 ...

Страница 3: ...ead to fire electric shock and or equipment failure Do not damage the power cord Do not bend too tightly stretch twist bundle with other cord pinch put under a heavy object and or heat it Damaged power cord could lead to fire short and or electric shock Do not unplug nor plug in the power plug with wet hands Deviation could lead to electrical shock and or equipment failure Do not insert or drop fo...

Страница 4: ...et which is connected to the ground If the outlet is not connected to a ground connect the ground cable to the ground terminal screw Connect the power cord firmly to the power port Otherwise this might cause electrical shocks and malfunctions Unplug the power cord if the STATUS ECO LED Status ECO mode or FAN LED Fan sensor blinks in orange system fault Deviation such as keep connecting for a long ...

Страница 5: ...reful in regards to environmental restrictions whereby the Ethernet Switch can be used Please isolate the business power lines and communication lines Isolate distribution lines and other distribution lines and low current power lines optical fiber cables metallic water conduits and gas conduits etc Noise may be generated in the communication lines which might cause communication glitches Do not c...

Страница 6: ...air cable leading to malfunction If you connect such a device it is strongly recommended that you install a surge protective device SPD on the twisted pair port side of this Ethernet Switch A lightning surge current voltage may be conducted to this Ethernet Switch through the power supply or ground wire connected to the power port leading to malfunction If a lightning surge current voltage may flo...

Страница 7: ...e spilled liquid water Dusty Possible static charge such as carpet Under direct sunlight Possible condensation High low temperature exceeding the specifications environment Strong vibration and or strong shock Failure to satisfy the conditions above may result in a fire electric shock equipment failure and or malfunction Such events are not covered by the warranty If it is used beyond the operatin...

Страница 8: ... configuration changes and verifications of the Ethernet Switch Remotely configure the PoE settings for each port Ports 1 to 24 The connection status for each port is detected by the power saving mode and it can suppress the power consumption to required volumes when not linked up Factory default deactivated Rapid Spanning Tree Protocol is supported allowing to build a system with redundancy The I...

Страница 9: ...sion Link Aggregation IEEE802 3ad Configurable up to 14 groups Max 8 ports per group VLAN IEEE802 1Q tagging VLAN protocol compatible Max 256 groups including the default VLAN Port based VLAN Internet Mansion function QoS IEEE802 1p compatible Supports 8 priority queues Management method ZEQUO assist Plus SNMP v1 v2c v3 Telnet SSH v2 Console WEB control screen Power supply function Ports 1 to 24 s...

Страница 10: ...Switch power will be shut off Others STP RSTP MSTP Supports the IEEE802 1X authentication MAC based port based MAC authentication WEB authentication Triple authentication STEP authentication IEEE802 1X supplicant Port monitoring Ring protocol IGMP snooping Loop detection shutoff function Storm control DSCP mapping function Login RADIUS function DHCP client function PoE scheduler function PoE auto ...

Страница 11: ...OWER LED Power lights in green STATUS ECO LED Status ECO mode lights in orange and self diagnosis of hardware is executed On completion of self diagnosis POWER LED Power STATUS ECO LED Status ECO mode TEMP LED Temperature sensor and FAN LED Fan sensor light in green and the Ethernet Switch starts operation as a Ethernet Switch As this Ethernet Switch succeeds in communicating with a terminal conne...

Страница 12: ...erminal screw 10 100 1000BASE T ports ports 1 28 Ports 1 to 24 can supply PoE power confirming with IEEE802 3at af Devices such as 10 100 1000BASE T terminal hub repeater bridge and Ethernet Switch can be connected to this port Install the device so that the length of twisted pair cable CAT5e or above becomes 100m or less SFP extension slot ports 25 28 Install SFP module It becomes exclusive usage...

Страница 13: ...ort s power supply is exceeding the upper limit or the total power supply of the Ethernet Switch is exceeding 96 W TEMP LED Temperature sensor Green Light The system is normally operating Orange Blink The temperature exceeded the set threshold of the internal temperature sensor Set threshold of the internal temperature sensor 57 C factory default FAN Fan sensor LED Green Light The system is normal...

Страница 14: ...lex or no device is connected Green Light Orange Blink Off LOOP HISTORY Green Light Loop has been detected within the last 3 days Off No loop detection history It is shut off via the loop detection and shutoff function storm control or the BPDU guard PoE are being supplied power Power is not being supplied or the PoE receiving equipment are not connected Also it is set in the ECO mode Single port ...

Страница 15: ...tically returns to a Base mode Status mode or ECO mode The Base mode is maintained even after the power is turned OFF Indication on the front panel and LED lamps You can display the following items using the LED display switch button Display for the connection with a connected terminal Status mode Display for the 1000 Mbps transmission rate GIGA mode Display for the full duplex or half duplex tran...

Страница 16: ...ode The Base mode is maintained even after the power is turned OFF LED lamps for each mode and LED lamps for ports 1 to 28 correspond as shown in Table 1 see page 14 Turns on the port LED with a orange light when a loop occurs in the corresponding port The Loop shutoff mode has the following 2 types of modes Block mode factory default When loops are detected the port statuses are automatically blo...

Страница 17: ...total power supply of the Ethernet Switch is exceeding 96 W 1 When configured IEEE802 3at factory default Exceeds 15 4 W when configured IEEE802 3af When the requested power supply for the Ethernet Switch is exceeded and it gets overloaded the power supply to the low priority ports is stopped and the port LEDs right of the ports whose power supply have been stopped blink in orange The priority set...

Страница 18: ... cable must be no less than 18 AWG and the length is 50 cm 3 The ground installed screw shall comply with 3 5mm minimum in nominal thread diameter and engage at least two complete threads into metal chassis with appropriate fixing hardware like washer 4 The grounding cable shall not be removed during normal operation servicing or maintenance 5 Installation steps Step 1 Ensure the detachable power ...

Страница 19: ...xing the mount brackets and the Ethernet Switch Fix the mount brackets to the four holes on each side of the Ethernet Switch using the screws Then securely install the Ethernet Switch on the rack using the four provided screws for mounting on a 19 inch rack or screws provided with the rack ...

Страница 20: ...n 3 enable configure config interface vlan 1 config if ip address 192 168 1 254 255 255 255 0 5 Enter the following command to save the setting config if exit config exit copy running config startup config 6 Since the following screen is displayed enter Y and the settings will be saved Screen 4 Confirm that the settings have been normally saved Screen 5 7 After configuring start with the terminals...

Страница 21: ... ML24TCPoE config if ip address 192 168 1 254 255 255 255 0 GA ML24TCPoE config if GA ML24TCPoE Product Number PN262492 Firmware Version x x x xx MAC Address 00 50 40 xx xx xx Serial Number xxxxxxxxxxx UserName manager Password GA ML24TCPoE enable GA ML24TCPoE configure GA ML24TCPoE config interface vlan 1 GA ML24TCPoE config if ip address 192 168 1 254 255 255 255 0 GA ML24TCPoE config if exit GA...

Страница 22: ... T 100BASE TX or 1000BASE T standard Auto negotiation may have failed Check the port settings of this Ethernet Switch or the terminal settings Is the correct Port LED display mode selected using the LED display switch button The Port LED left lights in orange Loop is occurring By removing the loop orange LED will be turned off LOOP HISTORY LED Blinks in green This is to notify that there is a port...

Страница 23: ...ly may not be possible depending on the installation environment In such cases use a UTP cable Is a CAT5e or better straight cable RJ45 8 8 used Is the cable connected to the port 1 24 that supports PoE power supply Ensure that either the port alone or the entire equipment is not overloaded Is the Powered Device connected to the port compliant with the IEEE802 3at standard or IEEE802 3af standard ...