53
5.3.2. Reboot
Select "System Tools" and then "Reboot" to open the screen shown in Figure 5-30.
On this screen, you can reboot this switch.
Figure 5-30 Reboot
Screen Description
Note:
There is no response during the reboot process. Reload the settings after
reboot is completed.
Reboot Option
Displays the reboot method. The factory default setting is "Normal".
Normal
Normal reboot is executed.
Factory Default
All settings are reset to factory default.
Factory Default
Except IP
All settings except the IP address are reset to factory
default.
Reboot Timer
Displays the time between execution of the reboot command and actual
reboot. The factory default setting is 0 seconds.