THRESHOLD VALUE FINE ADJUSTMENT MODE

10

 

9 When MODE indicator / ADJ (yellow) lights up, the set threshold value 

„

Step

Digital display

Description

1

{Press MODE key to light up MODE indicator / ADJ (yellow).

2

{Turn Jog switch to “+” side, to increase the threshold 

value.

{Turn Jog switch to “–” side, to decrease the threshold 

value.

3

{When Jog switch is pressed, the changed threshold 

"

4

{When MODE key is pressed 3 times, or for 1 sec., or 

more, the sensor returns to RUN mode and the incident 
light intensity is shown in the digital display (red).

{MODE indicator / RUN (green) lights up.
{The setting is complete.

Note: The adjustable area is limited as shown below. In order to adjust the threshold outside 

„  „

(100)

Threshold
value

Leak detection side

110

70

Light amount (%)

(100)

Threshold
value

Light amount (%)

Adjustable area

Adjustable area

130

90

Liquied present detection side

Adjustable area in Liquied (F9) mode: 90 to 130%

Adjustable area in Leak (F7) mode: 70 to 110%

DIGITAL DISPLAY SETTING MODE

11

 

9 When MODE indicator / DISP (yellow) lights up, the digital display (red) 

can be switched to the light-up mode, eco mode or inverse mode.

Step

Digital display

Description

1

{Press MODE key to light up MODE indicator / DISP 

(yellow).

2

{When Jog switch is turned to “+” side or “–” side, the 

mode in the digital display changes.

 :  This is the light-up mode in the digital display 

(red).

 

The digital display (red) always lights up.

 $ %      `     &

operation has not been done for 8 sec., or more, 

 “ 

z@&>^

is turned off.

 

When a key operation is done after the digital dis-
play is turned off or when the collective teaching 
is carried out, the digital display (red) lights up.

 :  This is the inverse mode of the digital display 

(red).

 

In the normal display condition, the display 
changes to the inverse display and in the inverse 
condition, the display changes to the normal dis-
play.

3

{When Jog switch is pressed, the set display blinks 3 

 

4

{When MODE key is pressed twice or for 1 sec., or more, 

the sensor returns to RUN mode and the incident light 
intensity is displayed in the digital display (red).

{MODE indicator / RUN (green) lights up.
{The setting is complete.

Note: The initial setting at the time of factory shipment is the light-up mode “ 

.”

FORCED OUTPUT MODE

12

 

9 When MODE indicator / OUT (yellow) lights up, the output can be com-

pulsory changed to ON or OFF regardless of the incident light intensity.

Step

Digital display

Description

1

{Press MODE key to light up MODE indicator / OUT (yellow).

(Present output state is displayed.)

2

{When Jog switch is turned to “+” side or “–” side, the 

output is compulsory changed to ON or OFF.

{          

   

{When the output is compulsory changed to ON, the op-

eration indicator (orange) lights up.

3

{Press MODE key to return the sensor to Step 1.

4

{When MODE key is pressed, the sensor returns to RUN 

mode and the incident light intensity is displayed in the 
digital display (red).

{MODE indicator / RUN (green) lights up.

SENSITIVITY SELECTION FUNCTION

13

 

9 If Jog switch is pressed for 3 sec., or more, when MODE indicator / ADJ 

>& ^&=  & -
sitivity, or set to automatic sensitivity.

Note: The initial setting at the time of factory shipment is the automatic sensitivity setting
 “ 

.”

Step

Digital display

Description

1

{Press MODE key to light up MODE indicator / ADJ (yellow).

2

{Press Jog switch for 3 sec. or more. 

(The sensor goes into the sensitivity setting condition.)

{MODE indicator / RUN (green) blinks.

3

{When turning Jog switch to “+” side or “–” side, the digital 

display (red) and MODE indicator / RUN (green) blinks, 
and the sensitivity can be selected.

 :  Automatic sensitivity setting

 

After selecting the automatic sensitivity, the opti-
mum sensitivity is set by carrying out teaching.

 :  Low sensitivity setting
 :  High sensitivity setting

4

{When Jog switch is pressed, the setting display blinks 3 

 

'

{MODE indicator / TEACH (yellow) lights up and 

“ 

 ” 

or “ 

 ”

 is displayed in the digital display (red).

{After sensitivity selection, carry out the teaching.

For the setting method of teaching, refer to “

INDI-

VIDUAL TEACHING MODE

.”

=?@K,Q=WZ[\,.] &^

14

Note: The initial setting at the time of factory shipment is the without timer condition “ 

.”

 

9 The timer setting can be done by pressing the jog switch for 3 sec., or 

more, when Liquid (F9) mode “ 

 ” has been set and MODE indicator 

/ DISP (yellow) lights up. In case of Leak (F7) mode “ 

,” the display 

does not change to the timer function.
For the selection method of Leak (F7) mode / Liquid (F9) mode, refer to 

INDIVIDUAL TEACHING MODE

” or “

COLLECTIVE TEACHING 

MODE

.”

 

9 This product incorporates a delay timer which reduces the effect of air 

bubbles, etc.

 

Timer 
operation

Sensing 

condition

NO/NC
selection function

NC
(Normal close)

NC
(Normal close)

NO
(Normal open)

Normal

Delay timer

NO
(Normal open)

T

Liquied
present

Liquied 
absent

ON

OFF

ON

OFF

ON

OFF

ON

OFF

Timer period: T = 10ms, 100ms, 1,000ms

T

T

T

T

T

Step

Digital display

Description

1

{Confirm if the sensor is in Liquid (F9) mode “ 

 ” in

INDIVIDUAL TEACHING MODE

” or “

COLLEC-

TIVE TEACHING MODE

.”

2

{Press MODE key to light up MODE indicator / DISP (yellow).

3

{Press Jog switch for 3 sec., or more.

(The sensor goes into the timer setting condition.)

{MODE indicator / RUN (green) blinks.

4

{When Jog switch is turned to “+” side or “–” side, the 

digital display (red) and MODE indicator / RUN (green) 
blinks, and the timer period can be chosen.

 :  Without timer
 :  10ms timer
 :  100ms timer
 :  1,000ms timer

'

{When Jog switch is pressed, setting display blinks 3 

 

6

{The sensor returns to Step 2.

7

{When MODE key is pressed twice or for 1 sec., or more, 

the sensor returns to RUN mode and the incident light 
intensity is displayed in the digital display (red).

{MODE indicator / RUN (green) lights up.
{The setting is complete.

Содержание FX-301-F

Страница 1: ...f the quick connection cable align its release lever with the groove 2 Insert the connector till a click is felt CONNECTION 3 Note Take care that if the connector is pulled out without pressing the release lever the re lease lever may break Do not use a quick connection cable whose release lever has broken Further do not pull by holding the cable as this can cause a cable break 1 Pressing the rele...

Страница 2: ... display Description 1 Insert leak detection fiber or liquid detection 2 Press MODE key to light up MODE indicator ALL yellow Turn the jog switch to or side to set to either Leak F7 mode or Liquid F9 mode In case Liquid F9 mode is set the model indi cator green lights up 3 Press Jog switch in no leak condition with leak detection Then on the digital display moves from top left to top right and fro...

Страница 3: ...rn the sensor to Step 1 4 When MODE key is pressed the sensor returns to RUN mode and the incident light intensity is displayed in the digital display red MODE indicator RUN green lights up SENSITIVITY SELECTION FUNCTION 13 9 If Jog switch is pressed for 3 sec or more when MODE indicator ADJ sitivity or set to automatic sensitivity Note The initial setting at the time of factory shipment is the au...

Страница 4: ...mmercial switching regulator ensure that the frame ground F G terminal of the power supply is connected to an actual ground 9 In case noise generating equipment switching regulator inverter motor etc is used in the vicinity of this product connect the frame ground F G terminal of the equipment to an actual ground 9 _ ply is switched on 9 Make sure to use the optional quick connection cable for the...

Отзывы: