INSTALLATION INSTRUCTIONS

CAUTION

5

Do not place pets and plants 

directly exposed to supply air outlet 

or exhaust air outlet.

Otherwise, it may cause discomfort to 

pets and dry out plants.

Heat-insulate the outdoor duct

 (including the indoor side, if 

necessary) to prevent condensation. 

When the ceiling is subject to high 

temperature and high humidity, 

install a ventilator on the ceiling. 

Do not install the product in an 

environment where the indoor 

temperature is significantly lower 

than the outdoor temperature.

If heat insulation is not adequate, 

condensate may enter the property 

causing damage.

Otherwise, it may cause fire and electric 

leakage.

Otherwise, it may cause condensation, 

electric shock and malfunction.

INSTALLATION AND OPERATING REQUIREMENTS

It must operate with filter.

If filter is not used, heat exchange core will 

be clogged with dirt and dust. The 

performance of the product will be 

affected, and the product may no longer 

operate.

Turn on/off the switch correctly.

If repeatedly turning on or off the 

switch, it will affect the product 

operations and damage the relay 

in the product.

To avoid accidents, the product 

shall be installed at least 2.3 m 

above the ground level.

(1) Excessive bending

(2) Multiple bends.

(3) Reduction in diameter of connecting 

      duct

Please avoid the following duct installation

.

It may cause the unexpected operation.

Ceiling board

ERV

The ground

2.3 m

Do not use the

Normal ventilation

during winter.

Condensation will be produced inside the 

supply air outlet if operation mode 

Normal ventilation

is used in a heated 

room during winter.

Содержание FV-15ZY1

Страница 1: ...carefully read USE AND MAINTENANCE INSTRUCTIONS P 16 17 of this instructions before operation Please retain this booklet for future reference Model No INSTALLATION AND OPERATING INSTRUCTIONS Energy Re...

Страница 2: ...f the supply cord is damaged it must be replaced by manufacturer or its service agent or a similarly qualified person in order to avoid a hazard SAFETY INSTRUCTIONS Please observe strictly 2 Otherwise...

Страница 3: ...duct it may cause the fire Otherwise it may cause poisoning or result in a fire due to internal corrosion or deterioration of the product Do not install the product or the room air inlet in places suc...

Страница 4: ...ise the operation of rotation part will cause the personal injury ERV Otherwise dew may be generated inside the product causing electric shock or water dripping and thus leading to property damage Do...

Страница 5: ...lectric shock and malfunction INSTALLATION AND OPERATING REQUIREMENTS It must operate with filter If filter is not used heat exchange core will be clogged with dirt and dust The performance of the pro...

Страница 6: ...unit Be careful of frost and dew 1 Energy saving ventilation Thanks to efficient recovery of thermal energy lost during Ventilation load incurred by outside air you can save an air conditioning fee 2...

Страница 7: ...uctions The following accessories are provided with the product in the package When you unpack check if the accessories are all included If not please contact your dealer Drawing No Name and Purpose Q...

Страница 8: ...ART NAMES AND DIMENSIONS Applicable duct diameter D E F FV 1HZY1 1224 1141 1127 1004 808 202 245 300 663 185 5 121 168 250 1224 1368 1127 1231 808 202 G 122 122 245 300 860 185 5 121 168 250 FV 2KZY1...

Страница 9: ...maintenance 2 During reverse installation the position of the inspection opening should also meet the dimensional relationship shown in Figure 2 A B 450 450 550 100 Figure 1 Figure 2 Above 25 mm Above...

Страница 10: ...port Support Room air duct Room air duct Pipe hood Pipe hood EA OA Outside air OA Outside air Exhaust air EA Exhaust air Supply air Supply air Room air RA SA SA Room air RA Figure 1 Figure 3 Backdraft...

Страница 11: ...pipe contacting with the metal structure Otherwise it may cause electric shock or fire WARNING When the product is used in an environment exposed to many insects or with street lights around the outsi...

Страница 12: ...n the terminal block twist together the copper strands of each core pass the wires through the corresponding wire plug and wire clip insert them into the wiring part of the terminal block and ensure t...

Страница 13: ...5 mm2 to connect the terminal SW1 COM to the volt free contact Perform wiring according to the local laws and regulations When interlocking with air conditioner Connect the FV 1HZY1 and FV 2KZY1 mode...

Страница 14: ...245 24 5 147 130 500 47 300 105 450 38 270 83 400 30 240 64 350 23 210 150 650 54 390 122 585 44 351 96 520 34 5 312 74 455 26 5 273 150 800 54 480 122 720 44 432 96 640 34 5 384 74 560 26 5 336 150 1...

Страница 15: ...OW TO INSTALL WARNING FV 1HZY1 FV 2KZY1 FV 65ZY1 FV 80ZY1 FV 1KZY1 FV 15ZY1 FV 25ZY1 FV 35ZY1 FV 50ZY1 Figure 8 Fix the screws removed in step P 12 onto the cover of the electrical equipment box again...

Страница 16: ...er regularly TEST RUN In case of any abnormality please immediately turn the dedicated circuit breaker to OFF and confirm the wiring again Situation Analysis Description The product does not start imm...

Страница 17: ...causing injury Please shut off the all pole switch before maintenance Otherwise it may cause electric shock and injury Do not incline the product during disassembly The accumulated water inside the p...

Страница 18: ...iency may decrease depending on the operating environment and time When cleaning the outdoor filters if you observe that the side to which the arrows of the outdoor filters point become black please r...

Страница 19: ...e butterfly bolts that secure the inspection cover Figure 1 Rotate the inspection cover along the direction indicated by arrow A Then slide and remove the inspection cover along the direction indicate...

Страница 20: ...leaner Vacuum cleaner Do not clean the outdoor filters by washing them with water Otherwise it may damage the outdoor filters and degrade their performance CAUTION Please pay attention to the installa...

Страница 21: ...RAM Connect wires indicated by dashed lines Please use the switch with rated current above 10 A Second Unit Power source and all pole switch to be supplied to on and after second unit Second Unit Powe...

Страница 22: ...tch in the mode off Is there a power failure Is the filter clogged with dust Please turn on the all pole switch After the power supply recovers press the switch to try running Please conduct maintenan...

Страница 23: ...s due to the impact of ambient sound the noise value will be greater than the target value The noise rises by about 1 dB A under reverse installation The air volume in normal ventilation mode is basic...

Страница 24: ...the dealer to purchase Filter Remote control Model No FV SWGR1 Model No Outdoor Filter FV 15ZY1 FV 25ZY1 FV 50ZY1 FV 35ZY1 FV FP15ZY1 FV FP25ZY1 FV FP50ZY1 FV FP35ZY1 FV 65ZY1 FV FP65ZY1 FV 80ZY1 FV F...

Отзывы: