Panasonic FV-11VF2 Скачать руководство пользователя страница 5

GENERAL SAFETY INFORMATION CONTINUED

Circulating fan unit

Red

White

Black

Motor(C)

White

Thermal cut-off

o

o

(230 F (110 C))

Heater

(1400W)

Thermostat

o

o

(140 F (60C))

Fuse

(20A)

Ventilating fan unit

Red

White

Black

Motor(V)

Capacitor

B

la

c

k

W

h

it

e

W

h

it

e

B

la

c

k

Junction box

Green

Earth ground

Power Supply
AC120V 60Hz

S

w

it

c

h

(n

o

t

in

c

lu

d

e

d

)

S

w

it

c

h

(n

o

t

in

c

lu

d

e

d

)

WIRING DIAGRAM

WARNING:

To reduce the risk of fire, electric shock or injury to persons, observe the following:

Use this unit only in the manner intended by the manufacturer. If you have any questions, please contact 
the manufacturer.

Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction. Neither unauthorized modification, repair nor
disassembly is allowed.

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel
buming equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection Association (NFPA), and the
American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code
authorities.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Ducted fans must always be vented to the outdoors.

Solid state controls may cause harmonic distortion which can cause motor humming noise. To reduce the
risk of fire or electric shock, do not use this unit with any solid-state control device.

Never place a switch where it can be reached from a tub or shower.

Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for
installation in Canada only.)

Use only on 20 ampere branch circuit.

A.

B.

C.

D.

E.

F.

G.

I.

J.

H.

Before servicing or cleaning unit, switch power off at service panel and lock panel cabinet to prevent 
power from being switched on accidentally. If the panel cabinet cannot be locked, securely fasten a 
clearly visible warning label to the service panel.

PCB

O

N

O

F

F

O

N

O

F

F

Black

Power Supply
AC120V 60Hz

Circulating fan unit

Motor(C)

Earth ground

Junction box

Motor(V)

Ventilating fan unit

O

N

O

F

F

O

N

O

F

F

O

F

F

O

N

O

N

O

F

F

PCB

Red

White

Black

White

Black

Fuse

(20A)

Thermal cut-off

o

o

(230 F (110 C))

Heater

(1400W)

Thermostat

o

o

(140 F (60 C))

Lighting unit

Fluorescent lamp

Electronic

ballast

W

h

it

e

B

la

c

k

F

u

s

e

(3

.1

5

A

)

Red

White

Black

Capacitor

Night lamp

B

la

c

k

W

h

it

e

B

la

c

k

W

h

it

e

B

la

c

k

B

la

c

k

W

h

it

e

Green

S

w

it

c

h

(n

o

t

in

c

lu

d

e

d

)

Power Supply
AC120V 60Hz

Power Supply
AC120V 60Hz

Power Supply
AC120V 60Hz

S

w

it

c

h

(n

o

t

in

c

lu

d

e

d

)

S

w

it

c

h

(n

o

t

in

c

lu

d

e

d

)

Содержание FV-11VF2

Страница 1: ...III Maintenance Cleaning I Maintenance Replacement of lamp II Model No FV 11VH2 FV 11VHL2 Ventilating Fan Thank you very much for having purchased our Ventilating Fan FV 11VH2 FV 11VHL2 back cover back cover ...

Страница 2: ... the noise level The heater for this unit is a 1400 W sheathed heater A thermostatand thermal cut off switch have been added for safety in case of an abnormal temperature rise in the heater The lighting unit is an energy saving lighting device which uses two 18 W fluorescent lamps and produces almost the same illumination as a standard 100 W incandescent lamp FV 11VHL2 UNPACKING SUPPLIED ACCESSORI...

Страница 3: ...SIONS 2 1 8 54 8 14 357 8 18 1 8 460 2 1 2 62 11 7 8 301 13 1 4 337 8 7 5 8 195 5 128 7 11 1 4 285 5 18 1 8 460 7 3 4 196 1 25 16 407 19 1 2 497 19 1 2 497 16 407 11 1 4 285 5 5 128 7 7 3 4 196 7 5 8 195 2 1 2 62 11 7 8 301 ...

Страница 4: ... has a fluorescent lamp that contains mercury Disposal may be regulated in your community due to environmental considerations For disposal or recycling information please contact your local authorities or the Electronics Industries Alliance http www eiae org Vent 0 1 WG cfm 8 Make sure that all duct work is properly vented 9 DO NOT INSTALL THIS UNIT OVER ABATHTUB OR SHOWER ENCLOSURE 15 6 7 1 17 8 ...

Страница 5: ...s When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors Solid state controls may cause harmonic distortion which can cause motor humming noise To reduce the risk of fire or electric shock do not use this unit with any solid state control device Never place a switch where it can be reached from a tu...

Страница 6: ... ST4 2X20 2 Screw ST4 2X8 Suspension bracket Suspension bracket 2 Insert the suspension bracket into the fan body Select the suspension bracket as shown below Fig 1 Tape Fan body Warning label Fig 4 2 Joist 2 Long screws ST4 2X20 Screw ST4 2X12 Joists 16 inches and 19 2 inches horizontal joists Fig 4 1 16 inches and 19 2 inches horizontal joists refer to Fig 4 1 19 2 inches vertical joists and 24 ...

Страница 7: ...ent lamps and then install the night lamp Fig 8 Fluorescent lamp 1 2 5 8 3 1 9 17 3 8 441 Screw driver Fig 6 Junction box plate Black to black White to white White to white Black to black Black to black White to white Black to black Junction box Green to green Wire nut Fan body Joist 4 Long screws ST4 2X20 Slot Mounting spring Grille Switch labels Switch labels For Model FV 11VHL2 For Model FV 11V...

Страница 8: ...Suspension bracket C B Select the suspension bracket according to spacing A as shown below Spacing A on center joists 16 inches 19 2 inches horizontal joists 19 2 inches vertical joists B 13 1 4 15 1 2 336 394 14 3 4 16 3 4 374 425 16 1 2 18 3 4 419 476 1 Before installation remove warning lable and the tape that is securing the adapter and the damper Fig 1 Keep the distance C 1 2 inch 12 7 mm for...

Страница 9: ...ep 5 of installation page 7 to complete the installation work 1 Before installation remove warning lable and the tape that is securing the adapter and the damper Fig 1 INSTALLATION BETWEEN JOIST MOUNTING CONTINUED Fig 13 Fig 14 Fig 14 6 Follow step 5 of installation page 7 to complete the installation work Fig 13 Fig 14 Joist 2 Long screws ST4 2X20 4 Long screws ST4 2X20 Joist 2 Screw ST4 2X12 ...

Страница 10: ...17 Fig 18 Fig 19 Fig 20 Fig 17 Fig 18 Fig 19 Fig 20 o o 60 C 140 F MAINTENANCE CLEANING 2 1 Slot Mounting spring Grille Gloves Vacuum cleaner 1 5 Replace grille Do not allow any water to get into the motor ...

Страница 11: ...g 22 or the 4 W night lamp Fig 21 replace the grille Fig 17 of page 10 Fig 21 MAINTENANCE REPLACEMENT OF LAMP 2 Remove the 4 W night lamp Fig 21 Fluorescent lamp Fluorescent lamp 4 Be sure to remove the night lamp before removing fluorescent lamps Night lamp ...

Страница 12: ...ll flex joints In attic installation caulk box to drywall 2 3 ft straight run before elbow Caulk termination to duct Dryer hood type vent with backdraft flap s Properly insulate the area around the fan to PANASONIC CONSUMER ELECTRONICS COMPANY Division de Panasonic Corporation of North America PANASONIC CANADA INC 5770 Ambler Drive Mississauga ON L4W 2T3 www panasonic com www panasonic ca One Pana...

Отзывы: