Fig. 8
Fig. 9
2 Long screws
(ST4.2X20)
Screw
(ST4.2X10)
II
Conduit
Junction box cover
Circular duct
Joist
Fan body
Adaptor
claws
INSTALLATION
JOIST MOUNTING-
CONTINUED
II
II
(
)
INSTALLATION
JOIST MOUNTING-
CONTINUED
II
II
(
)
7
Make sure that adaptor claws are properly inserted
into body slots.
IMPORTANT:
5. Insert the fan body into joists. (Fig. 8)
6. Secure the fan body to adaptor by using thumb
screw.
7. Secure
to joists by using
long screws (ST4.2X20) and secure it to fan body
by using screw
(ST4.2X10) in vertical direction.
(Fig. 9)
the suspension bracket
II
8. Follow step 5 to 9 of installation ( page 5~page6 )
to complete the installation work.
I
Joist
Receptacle
Thumb