background image

 

 

 

SIZING

Need to choose 10/20 CFM mode when installing.

 

Ventilation Capacity Requirements  

(CSA-F326)

10 CFM

Single Bedroom

Living room

Family room

20 CFM

Master Bedroom

Large Basement room

Spot Ventilation

Need to choose 20/40 CFM mode when installing.

ASHRAE 62.2 2010

 

1 Bedroom

2 Bedrooms

3 Bedrooms

20 CFM

500 sq ft.

N/A

N/A

40 CFM

2500 sq ft.

1750 sq ft.

1000 sq ft.

Whole House Ventilation (IAQ)

Sizing example 1 (based on ASHRAE 62.2):

TWO BEDROOMS at 1600 SQ. FT. 

    

Master Bedroom (7.5 CFM x 2) =   15 CFM

Second Bedroom  

=  

7.5 CFM

1600 SQ. FT. x .01  

=  

16 CFM

_________________________________________________

Total  

 

38.5 CFM

Use WhisperComfort set at 40 CFM   

Sizing example 2 (based on ASHRAE 62.2):

FOUR BEDROOMS at 2200 SQ. FT. 

    

Master Bedroom (7.5 CFM x 2)  

=   15 CFM

Other 3 Bedrooms (7.5 CFM each)   =   22.5 CFM

2200 SQ. FT. x .01  

=   22 CFM

________________________________________________

Total  

 

59.5 CFM

Use 2 WhisperComfort or 1 WhisperComfort and  
1 WhisperGreen

®

*  

* WhisperGreen

®

 are Panasonic exhaust fans with variable speed DC motor and 

built-in controls. Ideal for both bathroom intermittent ventilation and whole house 
continuous run ventilation.

Отзывы: