● When rewriting during RUN is performed during the operation, the PWM output stops while a
program is being rewritten.
■
Example of program
The following sample shows the program for performing the PWM output with 10 kHz and the
duty ratio of 50% from CH0 (Y0).
● For details of the allocations of I/O and flags, refer to “Allocation of Memory Areas”.
REFERENCE
11.2.3 When Using PWM Output Function
9.1.4 [F173 PWMH] PWM Output Instruction (Control Code Specification)
The PWM output is performed according to the set parameters.
■
Instruction format
■
Operand
Operand
Settings
S
Starting address of the memory area storing the parameters of the PWM output.
S
Specify the control code. K0 to K30
9.1 PWM output function
WUME-FPXHPOSG-01
9-5