Ref. No. 2G
Procedure 2A
→
→
→
→
2B
→
→
→
→
2C
→
→
→
→
2D
→
→
→
→
2E
→
→
→
→
2F
→
→
→
→
2G
Attachment of the Housing.
1. Place the driving block onto the housing A and place the spring
for release lever and the hook release lever.
2. Place the switch assembly, operation panel, click spring and F/R
selector handle onto the housing A.
NOTE :
Make sure that the lead wires are pressed fit firmly.
3. Close the housing A and B with pushing the radiating plate on the
direction of the arrow and tighten 8 housing screws.
NOTE :
Confirm to set the radiating plate properly. If the radiating plate
lean toward the motor brush side, the housing B can not be
closed.
4. Place the H/L change handle into the rail properly.
5. Insert the belt hook into the housing and tighten with hook bolt.