- 8 -
Starting the control panel
1. Release the hold switch.
. To illuminate the control panel
1
Release the lock button
2
Press (Control panel is lit.)
●
The count display lamp and “UP” or
“DOWN” are illuminated.
Setting the count functions (Screw
count setting/Count system setting)
1. Press while the control panel is
illuminated.
Each time is pressed, the screw
count setting and count system set-
ting switch and flash.
●
Screw count setting
→ Count display lamp flashes.
●
Count system setting
→ “UP” or “DOWN” flashes.
. Screw count setting
Set the number of screws with
or
.
●
The range can be set within 0 – 99.
●
0 is not counted.
Count system setting
Press . “UP” or “DOWN” will begin
to flash. Next select
(“UP”) or
(“DOWN”).
●
Press and hold the (
) or ( )
buttons while setting the torque to
vary the value continuously.
< Count System “UP” >
●
Displays the count for the number
of screws driven.
(
Set number )
The settings are activated by pushing
.
●
When the set number of screws is
reached, the buzzer sounds and
the count value resets to zero.
< Count System “DOWN” >
●
Displays the count for the remain-
ing number of screws to be driven.
( Set number
)
●
When the set number of screws to
be driven is reached, the buzzer
sounds and the count value resets
to original set number.
3. The settings are activated by pushing
.
●
The previous setting will be cleared.
4. To prevent changes in the set values
due to operational errors.
ON
●
Turn the HOLD switch
to ON.
Convenient function settings (buzzer
sound setting/double tightening
counting prevention time setting)
1. Press for or more seconds while
the control panel is illuminated.
●
Count display lamp “F1” is illumi-
nated.
Each time
is pressed, the
buzzer sound setting and double
tightening counting prevention time
setting can be switched.
●
“Buzzer sound setting”
→ “F1” is illuminated.
●
“Double tightening counting pre-
vention time setting”
→ “F2” is illuminated.
. Buzzer sound setting
The buzzer sound can be selected
with when “F1” is illuminated.
Operation
Display
Sound Frequency
b3
High pitched sound
(Approx. 4 kHz)
b
Medium pitched
sound (Approx. 3
kHz)
b1
Low pitched sound
(Approx. kHz)
b0
No sound (OFF)
●
If is pressed, the buzzer sound
saved from the previous setting is
displayed.
Double tightening counting preven-
tion time setting
Press to illuminate “F” and select
the time with .
Содержание EY7411 - CORDLESS DRILL & DRIVER
Страница 17: ... 17 MEMO ...
Страница 116: ...No 1 EN GR FR IT ND ES DN SW NR FN EY971074116 2012 11 Printed in Japan ...