8
EX-Z12□, EX-Z12F□
<Parallel deviation diagram (typical)>
200
0
100
0
50
50
100
100
Operation distance ℓ(mm)
Center
Left
Right
(L2)
(ℓ2)
Sensing distance L
(mm)
In case using at sensing distance (L2) 200mm, the
operation point (ℓ2) is approx. 30.5mm according
to the diagram at left.
The installation interval is
Approx. 30.5mm X 2 = approx. 61mm
Thus, install the product to approx. 61mm or more
away.
<Installation interval>
200mm
61mm
61mm
EX-Z13□, EX-Z13F□
<Parallel deviation diagram (typical)>
800
400
600
0
200
0
50
50
100
100
Operation distance ℓ(mm)
Center
Left
Right
(L3)
(ℓ3)
Sensing distance L
(mm)
In case using at sensing distance (L3) 500mm, the
operation point (ℓ3) is approx. 81.9mm according
to the diagram at left.
The installation interval is
Approx. 81.9mm X 2 = approx. 163.8mm
Thus, install the product to approx. 163.8mm or
more away.
<Installation interval>
500mm
163.8mm
163.8mm