2-E
NGLISH
Replacing the lamp unit
NOTE:
B
If the lamp usage time has passed 2 000 hours (when LAMP POWER has
been set to “NORMAL”), the projector will switch to standby mode after
approximately 10 minutes of operation. The steps
*
to
-
on the following
pages should thus be completed within 10 minutes.
B
If the LCD projector is operating, turn off the power by the following procedure
and wait for the lamp unit to cool down before carrying out replacement.
(1) Hold down the POWER button for at least 0.5 seconds or press the
POWER button twice to turn off the power.
(The power indicator lamp will illuminate orange.)
(2) Wait until the cooling fan stops and the power indicator lamp switches
to red.
(3) Turn off the MAIN POWER switch and disconnect the power cord plug
from the wall outlet.
Precautions with regard to safety
Warning
The lamp unit should only be replaced by a qualified technician.
When replacing the lamp, allow it to cool for at least one hour before
handling it.
B
The lamp cover gets very hot, and contact with it can cause burns.
Notes on replacing the lamp unit
B
The light generating lamp is made of glass, so dropping it or allowing it to
hit hard objects may cause it to burst. Be careful when handling the lamp.
B
Dispose of the removed the old lamp with the same care that would be
taken with a fluorescent light.
B
A Phillips screwdriver is necessary for removing the lamp unit.
B
Grip the handle when you remove the lamp unit.
Some parts of the lamp unit are sharpened and
may cause injury.
NOTICE:
For USA only
Hg-LAMP CONTAINS MERCURY, Manage in Accord with Disposal Laws,
See: www.lamprecycle.org or 1-888-411-1996
p05-12(LAX100)en̲fr 07.4.9 23:29 ページ 2