EP1285
ORDER NO.0808U08C1
-
42
-
7.
CHECKING
7.1. Checking the Controller and the Massage mechanism block
Massage block stops instantly if any abnormal phenomena like motor locking happen at the test mode, however the Controller
test mode continues.
Controller test mode
1. Start the Massage mechanism block test mode and make all the LEDs of the Controller light, and check if the P sound is
heard twice.
2. Check if each LEDs light when each Buttons are pushed.
Data transmission between the Main PCB and the Controller can be checked by the test mode of the Controller. If there is
something wrong with the data transmission, LEDs do not light. It is assumed that the Controller cord connection is not proper.