(4) Insert the red, black(110V) / blue(220V), yellow, orange, Violet (110V)
/brown (220V) between the guide post of air flow assembly and
align heater insulator slot at lead wire position as shown in fingure 5.
(5) Set air outlet grill and outlet ring to heater block by align rib of air outlet
ring with slot of front housing as shown in Figure 6.
(6) Put heater block into front housing by align heater base board with
air outlet ring.
(7) Assembly housing cover and back housing
with front housing, install swivel ring and
drive tapping screw size 2.6x6 as shown in Figure 7.
(8) Install handle B, by make sure align all
lead wire at right hand side of screw bush
as shown in Figure 8.
<For Taiwan>
<For Korea>
<For Other>
Heater insulator
Figure 5
Figure 7
Screw size 2.6x6
Figure 8
Figure 6