3. TROUBLESHOOTING GUIDE

Refer to WIRING CONNECTION DIAGRAM.

< TROUBLE > 

< CHECK > 

< REMEDY > 

OK 

<CHECK MOTOR HEATER ASSEMBLY> 

Check if there are odd objects between  

joints of thermo switch or not  

(Figure 3) 

Remove the odd objects  

between joints 

Found odd object 

No odd objects 

Replace the  

MOTOR HEATER ASSEMBLY

 

Figure 3 

Thermo Switch 

Hot air is not emitted  

<CHECK COOL SWITCH BUTTON> 

Check the conductivity between the terminal 1  

and 2 by push and hold  

the COOL SWITCH BUTTON  

(Figure 2) 

<CHECK TEMPERATURE SWITCH>

 

Check the conductivity between the terminal 2 

 

and 4 by setting  

the TEMPERATURE SWITCH to Position 2  

(Figure 1)

 

Replace the  

MAIN SWITCH 

NG 

OK 

Replace the  

COOL SWITCH BUTTON 

NG 

COOL SWITCH BUTTON

 

Lead Wire (Orange) 

Lead Wire (Blue and Red) 

For EH-NE81-84 only

 

Figure 2 

Figure 1 

Lead Wire (Black) 

Lead Wire (Brown) 

Lead Wire (Orange) 

Temperature Switch

 

OK 

Содержание EH-NE83

Страница 1: ...PAGE 1 Warning 2 2 Specifications 2 2 3 Troubleshooting Guide 3 3 4 Disassembly and Assembly Instructions 5 5 5 Wiring Connection Diagram 12 12 6 Schematic Diagram 15 13 7 Exploded View Replacement Parts List 16 15 Panasonic Corporation 2013 Unauthorized copying and distribution is a violation of law ...

Страница 2: ...ong Pb free solder will tend to splash when heated too high about 1100 F 600 Power source Power consumption II Hot Air volume without nozzle Air temperature without nozzle II Hot Dimensions Cord length Weight Supplied accessory 90 K in case of room temperature 30 C W 90mm x D 220mm x H 270mm without power cord and nozzle 2 Specifications AC 220 240 V 50 60 Hz Code L 605 615 655 685 1 7 m Approx 53...

Страница 3: ...h Hot air is not emitted CHECK COOL SWITCH BUTTON Check the conductivity between the terminal 1 and 2 by push and hold the COOL SWITCH BUTTON Figure 2 CHECK TEMPERATURE SWITCH Check the conductivity between the terminal 2 and 4 by setting the TEMPERATURE SWITCH to Position 2 Figure 1 Replace the MAIN SWITCH NG OK Replace the COOL SWITCH BUTTON NG COOL SWITCH BUTTON Lead Wire Orange Lead Wire Blue ...

Страница 4: ...f power cord CHECK MAIN SWITCH Check the conductivity between the terminal 1 and 4 by setting the MAIN SWITCH to Position 1 Figure 4 Replace the MAIN SWITCH Replace the MOTOR HEATER ASSEMBLY NG OK NG OK Replace the MOTOR HEATER ASSEMBLY Lead Wire Yellow Lead Wire Red Lead Wire Gray Lead Wire Orange For code 605 655 685 695 865 MAIN SWITCH Figure 4 ...

Страница 5: ...OUTLET RING and AIR OUTLET GRILL by rotating follow the direction below 2 Remove 3 TAPPING SCREWS by a cross slot screw driver then Remove AIR INLET RING 5 Take off HOUSING AB follow the figure below 3 Remove 2 TAPPING SCREWS at HOUSING A by flat blade screwdriver and 2 TORX SCREWS at HANDLE by Driver then remove HANDLE AB 6 Remove DISCHARGE COVER Counter clockwise rotation ...

Страница 6: ...sassembly and Assembly Instructions 4 1 Disassembly Instructions 7 remove Ion Holder from DISCHARGE COVER as figure below 8 Take off MOTOR HEATER ASSEMBLY and PLATE SPRING from HOUSING B Unclip this 2 ribs ...

Страница 7: ...4 2 Assembly Instructions 1 High voltage lead wire for Ion discharge must be fixing with Ribs from Heater holder as below picture ...

Страница 8: ...2 Install MAIN SWITCH PLATE AB and MAIN SWITCH HOLDER 3 Install Ion discharge in to DISCHARGE COVER Ribs of MAIN SWITCH HOLDER must fully lock with MAIN SWITCH 2 Ribs ...

Страница 9: ...4 Assemble MOTOR HEATER ASSEMBLY COOL SWITCH PLATE and PLATE SRPING into HOUSING B Lead wire to Heater block assembly must not on this area Position of component must be as below EH NE81 82 83 84 only ...

Страница 10: ...5 Assemble DISCHARGE COVER DESIGN COVER into HOUSING B 6 Assemble HOUSING A then tightening 2 TORX SCREWS 7 Assemble AIR INLET RING and 3 TAPPING SCREWS TAPPING SCREWS 2 6 10 TORX SCREWS 3 0 12 ...

Страница 11: ...8 Install a AIR OUTLET GRILL into AIR OUTLET RING Then install in to MAIN BODY with TAPPING SCREW 9 Install a FILTER FRAME ASSEMBLY clockwise rotation TAPPING SCREW 2 0 4 0 ...

Страница 12: ...5 Wiring Connection Diagram ...

Страница 13: ...Fixed Resistance R1 Fixed Resistance R2 Fixed Resistance R3 Power Cord Hi Voltage Circuit PCB Sensor Printed Circuit Board Diode Rectifier Main Switch O X X O I X X X X X X X X O O O X X O SW2 II O Specification Part name Symbol FCHW1 11 5 W m FCHW1 7 13 W m NCHW2 21 29 W m 80 5 C 15 A 250 V 142 C HV PCB Sensor PCB C1 C2 RHA RHB RHC RHD TH F1 R1 R2 R3 M 250VAC 15A 400 V 2A 250 V 10 A 0 22 µF 275 V...

Страница 14: ...7 EXPLODED VIEW REPLACEMENT PARTS LIST 7 1 Exploded View for EH NE83 All parts are supplied from PMFTH AP through PLAP 12 2 16 3 6 7 8 15 14 5 9 10 11 13 4 1 ...

Страница 15: ...CH PLATE AB BLACK 1 10 EHNE83MSW MAIN SWITCH 1 2PCS PACK INCLUDE 6 INSULATION TUBES 11 EHNE83MSHTW MAIN SWITCH HOLDER 1 12 EHNE83HS615W HOUSING AB ASSEMBLY 1 FOR K615 BLACK 12 EHNE83HS685W HOUSING AB ASSEMBLY 1 FOR K685 BLACK 13 EHNE83T3012W TORX SCREW 3 0 12 2 1 14 EHNE83T2004W TAPPING SCREW 2 0 4 0 1 15 EHNE83T2610W TAPPING SCREW 2 6 10 3 1 16 EHNE83AOGW AIR OUTLET GRILL 1 EHNE83S03W OPERATING I...

Отзывы: