9.3. Service Mode Table 1
The service modes can be activated by pressing various button combination on the player and remote control unit.
Player buttons
Remote control unit buttons
Application
Note
PAUSE
+
PLAY
0
Displaying the UHF display F_ _ _
Refer to section 9.2. Self-
Diagnosis Function (UHF
Display).
5
Jitter check, tilt adjustment
*Display shows xx_yyyzz
"xx" and "zz" shown to the right have nothing to do with the jitter
value. "xx" is the error counter, while "zz" is the focus drive value.
Refer to section 11.4. for Optical Pickup Tilt Adjustment
Procedure.
Refer to section 11.4.
Optical
Pickup
Tilt
Adjustment
6
Checking the region numbers and broadcast system
7
Checking the program version
Check the IC6301 FLASH
ROM program.
9
Lighting Confirmation Function of Display Tube
DISPLAY
Checking the laser drive current
Refer
to
section
8.5.
Optical
Pickup
Replacement Procedure.
PAUSE
Writing the laser drive current value after replacing the optical
pickup (do not use for anything other than optical pickup
replacement)
PAUSE
BWD-SKIP
PLAY
—
The user setting is returned to the state of the factory shipment. Refer
to
section
9.6.
Initializing
the
DVD
player.
9.4. DVD Self Diagnostic Function-Error Code
Error Code
Error Content
Additional error explanation
Defect 1
Defect 2
Defect 3
Defect 4
U, H error
U11
Focus error
H01
Tray loading error
H02
Spindle servo error
(Spindle servo, DSC SP motor, CLV servo error)
H03
Traverse servo error
H04
Tracking servo error
H05
Seek error
H06
Power error
Cannot switch off the power because of the panel
and system computer communication error
H07
Spindle
motor
drive
error
DSC related
F500
DSC error
DSC stops in the occurence of servo error (starup,
focus error, etc)
OPU
DV2
(IC3001)
DV2
(IC3001)
servo drive
F501
DSC not Ready
DSC-system
computer
communication
error
(Communication failure caused by idling of DSC)
DV2
(IC3001)
DV2
(IC3001)
F502
DSC Time out error
Similar disposal as F500
OPU
DV2
(IC3001)
DV2
(IC3001)
servo drive
F503
DSC
communication
Failure
Communication
error
(result
error
occured
although communication command was sent)
DV2
(IC3001)
DV2
(IC3001)
EEPROM
(IC6351)
F505
DSC Attention error
Similar disposal as F500
OPU
DV2
(IC3001)
DV2
(IC3001)
servo drive
F506
Invalid media
Disc
is
flipped
over,
TOC
unreadable,
incompatible disc
DISC
DV2
(IC3001)
DV2
(IC3001)
DV2
(IC3001)
ODC related
F600
Access
failure
to
management
information caused by
demodulation error
Operation stopped because navigation data is not
accessible caused by the demodulation defect
DV2
(IC3001)
DV2
(IC3001)
DV2
(IC3001)
F601
Indeterminate sector ID
requested
Operation stopped caused by the request to
access abnormal ID data
DV2
(IC3001)
DV2
(IC3001)
DV2
(IC3001)
F602
Access failure to LEAD-
IN
caused
by
demodulation error
LEAD IN data unreadable
F603
Access
failure
to
KEYDET
caused
by
demodulation error
Access failure to CSS data of disc
F610
ODC abnormality
No permission for command execution
DV2
(IC3001)
F611
6626
QCODE
don’t
read Error
Access failure to seek address in CD series
DV2
(IC3001)
20
DVD-LS90PP / DVD-LS93P
Содержание DVD-LS93P
Страница 8: ...8 DISASSEMBLY REASSEMBLY AND SERVICE POSITION 8 DVD LS90PP DVD LS93P ...
Страница 9: ...8 1 Disassembly 9 DVD LS90PP DVD LS93P ...
Страница 36: ...36 DVD LS90PP DVD LS93P ...
Страница 42: ...DVD LS90PP DVD LS93P 42 ...
Страница 56: ...DVD LS90PP DVD LS93P 56 ...
Страница 60: ...DVD LS90PP DVD LS93P 60 ...
Страница 61: ...18 EXPLODED VIEWS 18 1 Casing Parts Mechanism Section Exploded View 61 DVD LS90PP DVD LS93P ...
Страница 62: ...18 2 Mechanism Section Exploded View 62 DVD LS90PP DVD LS93P ...
Страница 63: ...18 3 Packing Accessories Exploded View 63 DVD LS90PP DVD LS93P ...