background image

External dimensions (W 

a

a

D):

6-3/16 

a

7-9/16 

a

6-13/16-inches 

(156.5 

a

191.5 

a

173 (mm))

Weight:

4.84 lbs (2.2 kg)

Operating temperature range:

32°F to 104°F (0°C to 40°C)

Storage temperature range:

–4°F to 140°F (–20°C to +60°C)

Operating humidity:

10 to 85% (relative humidity)

Transfer block

Signal transfer rate:

360 Mbps (AJ-CA901 to AJ-BS901)

Transfer distance:

300 m with diameter 8.6 mm cable (Fujikura)

500 m with diameter 14.5 mm cable (Fujikura)

Video transfer rate:

Signals from camera to base station:
Y signal:

18 MHz sampling rate, 10-bit

R-Y signal:

9 MHz sampling rate, 10-bit

B-Y signal:

9 MHz sampling rate, 10-bit

Signals from base station to camera:
RET signal:

FM modulation

Prompt signal: FM modulation

Audio transfer rate:

Signals from camera to base station:
46.875 kHz sampling rate, 16-bit
Signals from base station to camera:
11.71875 kHz sampling rate, 16-bit

Intercom

Microphone selection:

Switchable between dynamic microphone and carbon microphone

I/O level:

4-line/2-line: 0 dBm (600 

, balanced)

RTS:

1 Vp-p (200 

)

PGM:

0 dB (600 

, balanced)

Format:

Selectable between 4-line, 2-line, and RTS

Lines:

Base station to camera: 2 lines (ENG, PGM)
Camera to base station: 1 line (ENG)

S/N ratio:

50 dB or more (base station to camera) (camera to base station)

Distortion:

1.0% or less

Frequency range:

100 Hz to 10 kHz (± 3 dB) (camera to base station)
100 Hz to 5 kHz (± 3 dB) (base station to camera)

Dynamic range:

12 dB or more

Video system

Teleprompt output (PROMPT):

1 Vp-p (1 Vp-p input to AJ-BS901)

RET output:

1 Vp-p (1 Vp-p input to AJ-BS901)

Input connectors

Intercom connector:

XLR 5-pin

External DC power supply input connector: XLR 4-pin
RET SW connector:

8-pin

Output connectors

Teleprompt (PROMPT) output connector: BNC VBS, 1 Vp-p, 75 

RET signal output connector:

BNC VBS, 1 Vp-p, 75 

External power supply output connector:

XLR 4-pin

PGM audio output connector:

XLR 3-pin

Weight and dimensions shown are approximate.
Specifications are subject to change without notice.

9

Specifications

Input:

100 V DC (supplied by AJ-BS901)
12V DC IN (11.5 V to 17.0 V DC)

Power consumption: BS Input 100 V : 450 mA

EXT Input 12 V : 3.2 A

Indicates safety information.

Содержание DVCPRO AJ-CA901

Страница 1: ... this product Before operating this product please read the instructions carefully and save this manual for future use Operating Instructions Digital Triax Camera Adapter Model No AJ P EN F0903H0 3 Printed in Japan VQT0F80 EN ...

Страница 2: ...th the limits for a class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference t...

Страница 3: ...hout these instructions as the unit The unit is installed in a DVCPRO50 AJ SDX900 camera recorder and used together with the AJ BS901 base station to configure a transmission system which uses a tri axial cable to enable the camera recorder to be operated as a system camera Use of non compressed wide band 360 Mbps serial component signals makes high picture quality transmission possible so that th...

Страница 4: ...d The screw will be completely disengaged from the thread Mounting the AJ CA901 with the screw in the closed position could damage the connectors 3 Screw the coin screw to the closed position while pressing down on it Coin screw Follow the steps below to attach the unit to the camera recorder Note Depending on the version of the software being used with the camera recorder it may be necessary to u...

Страница 5: ...e RET1 and RET2 selection as well as intercom PTT push to talk and CALL Rear panel 7 DC OUT DC power supply output jack This is a DC 12 V output jack A current up to 500 mA can be output from this jack 6 DC 12V IN external power supply input jack When the unit is operated using an external power supply the AJ B95 AC adapter sold separately connects to this jack It is also possible to connect an ex...

Страница 6: ...m line multiplexed on the intercom line It has two positions ON and OFF AJ Camera Adapter MIC LEVEL INCOM PGM ON OFF ON OFF PTT DIGITAL TRIAX 1 2 3 4 Left side 3 Triax connector This connector is used to connect to the base station AJ BS901 using a triax cable 1 Prompter video output PROMPT OUT The prompter video signal input to the base station AJ BS901 is output from this jack 2 Return video out...

Страница 7: ...umber PRC07 R8F Tajimi Musen A B C D E F G H 5 4 3 2 1 INCOM 1 GND 2 INCOM TALK H 3 GND 4 INCOM RECEIVE H 5 PGM RECEIVE C DC 12V OUT 1 GND 2 3 4 12V Matsushita part number VJS3290 Manufacturer part number HA16PRH 5S Hirose Denki Manufacturer part number HA16PRH 4S Hirose Denki 4 3 2 1 DC IN 1 GND 2 3 4 12V Matsushita part number VJP3429 Manufacturer part number HA16RX 4P SW1 Hirose Denki 1 2 3 4 S...

Страница 8: ...which was removed Screws 4 Dynamic microphone Carbon microphone Switch Proceed as follows to select the dynamic microphone or carbon microphone as the intercom microphone Before proceeding with the work be absolutely sure to turn off the power CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other...

Страница 9: ...evel 4 line 2 line 0 dBm 600 Ω balanced RTS 1 Vp p 200 Ω PGM 0 dB 600 Ω balanced Format Selectable between 4 line 2 line and RTS Lines Base station to camera 2 lines ENG PGM Camera to base station 1 line ENG S N ratio 50 dB or more base station to camera camera to base station Distortion 1 0 or less Frequency range 100 Hz to 10 kHz 3 dB camera to base station 100 Hz to 5 kHz 3 dB base station to c...

Страница 10: ...kville MD 20850 301 738 3840 Broadcast PARTS INFORMATION ORDERING 9 00 a m 5 00 p m EST 800 334 4881 24 Hr Fax 800 334 4880 Emergency after hour parts orders 800 334 4881 TECHNICAL SUPPORT Emergency 24 Hour Service 800 222 0741 Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 905 624 5010 Panasonic de Mexico S A de C V Av angel Urraza Num 1209 Col de Valle 03100 Mexico D F 52 1 9...

Отзывы: