Key-protect is a function which prevents any unintentional 
change in the conditions which have been entered in each 
setting mode by making the sensor not to respond to the key 
operations.

KEY-PROTECT FUNCTION

9

Setting of key-protect

In the sensing mode, press       key contin-
uously until         appears. (4 sec. approx.)
Once       is displayed, release the key. 
Then the key-protect is set and the sensor 
enters into the sensing mode again.

MODE

Since the key-protect information is 
stored in an EEPROM, it is not erased 
even if the power supply is switched off.
Please take care to remember if the 
key-protect function has been set.

Release of key-protect

In the sensing mode, press       key contin-
uously until         appears. (4 sec. approx.)
Once         is displayed, release the key.
Then the key-protect is canceled and the 
sensor enters into the sensing mode again.

MODE

When the keys are to be operated, make 
sure that key-protect is released.

CONVERSION TABLE FOR PRES-
SURE UNITS

10

kPa

1

7.50062

1.01972

™

10

2

9.86923

™

10

3

1.01972

™

10

2

9.80665

™

10

3

7.35559

™

10

2

1

9.67841

™

10

5

1

™

10

4

1.33322

™

10

1

1

1.35951

™

10

1.31579

™

10

3

1.35951

™

10

3

9.80665

™

10

7.35559

™

10

2

1

™

10

4

9.67841

™

10

1

1

1.01325

™

10

2

7.60000

™

10

2

1.03323

™

10

4

1

1.03323

mmHg

(Torr)

atm

kgf/cm

2

mmH

2

O

1kPa

1mmHg
(1Torr)

1atm

1kgf/cm

2

1mmH

2

O

DIMENSIONS (Unit: mm)

11

3 digit LED
display (Red)

M1 setting
indicator (Red)

Pressure unit indicator
(mmH

2

O) (Red)

M2 setting
indicator (Red)

Operation
indicator (Orange)

Increment key

Decrement key

Mode selection
key

Pressure unit indicator
(kPa) (Red)

40

40

5.5

Pressure Lo-port

Pressure Hi-port

ȭ

3.7 cable 2m long

42.3

30

17

ȭ

4.6

ȭ

4.6

2-M3 female
threads 6 deep

25

32.5 10.6

13.6

Į

ە

Upper and lower threshold value setting

[lower threshold value (M1)] and [upper threshold value (M2)] of 
the comparative outputs are set.

Set to lower threshold value (M1) set mode

The lower threshold value (M1) and the upper threshold value 
(M2) can be entered in under the following conditions.

M1 < M2
No vacuum values

Set to sensing mode

Press      key.

MODE

The sensor returns to sensing mode after 
lower threshold value (M1) and upper 
threshold value (M2) have been set.
Since the values which have been set are 
stored in an EEPROM, they are not erased 
even if the power supply is switched off.

Enter lower threshold value (M1)

The registered lower threshold value (M1)
appears and blinks. The M1 setting indicator 
(red) and the pressure unit indicator (red) also 
blinks.

In the sensing mode, press      key.

MODE

Enter upper threshold value (M2)

Set to upper threshold value (M2) set mode

If set value M1 is larger than the registered 
upper threshold value (M2), the sum of the 
M1 value plus 1 digit appears and blinks.
Otherwise, the registered upper threshold 
value (M2) appears and blinks. The M2 
setting indicator (red) and the pressure unit 
indicator (red) also blinks.

In the lower threshold value (M1) set mode, 
press      key.

MODE

The upper threshold value (M2) can be set to a value of lower 
threshold value (M1) + 1 digit, or more, only.
If the output mode has been set to the window comparator 
mode (   ) in the initial setting mode, lower threshold value (M1) 
and upper threshold value (M2) should be set with a difference 
of 3 digits (0.03 kPa.D {3 mmH

2

O.D}) or more.


Enter using      key and      key.
If      key is pressed once, the set value 
increases by 1 digit and if      key is pressed 
once, the set value decreases by 1 digit.
Further, if      key or      key is pressed 
continuously, the set value changes quickly.

If the set pressure range is exceeded, either

(upper limit exceeded) or      (lower

limit exceeded) is displayed.

Using     key and     key, enter in a manner 
similar to that for entering lower threshold 
value (M1).

If the set pressure range is exceeded, either

(upper limit exceeded) or      (lower

limit exceeded) is displayed.

ە

ە

The models listed under “

SPECIFICATIONS

” 

come with CE Marking.
As for all other models, please contact our office.

Contact for CE

Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany

1

INTENDED PRODUCTS FOR CE MARKING

12

http://panasonic.net/id/pidsx/global

PRINTED IN JAPAN

© Panasonic Industrial Devices SUNX Co., Ltd. 2015

Overseas Sales Division (Head Office) 

2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 
Phone: +81-568-33-7861  FAX: +81-568-33-8591

For sales network, please visit our website.

Содержание DP-M Series

Страница 1: ...re sensing device in the sensor may get damaged Please do not compress the tube If the tube is compressed pressure exceeding the rated value may be generated damaging the diaphragm pressure sensing device Pressure Hi port Fix tubes on ports securely Pressure Lo port Flexible tubes silicone tube etc TYGON tube size internal dia 4mm external dia 6mm made by SAINT GOBAIN Not good ە ە Apply higher pre...

Страница 2: ...or codes and key protection sign are displayed Pressure unit indicator mmH2O kPa Red յ The indicator of the selected unit lights up during the sensing mode Both indicators turns off during the initial setting mode and during an error occurrence The indicator of the selected unit blinks during the upper and lower threshold value setting mode ո ն The settable digit is shifted cyclically at every pre...

Страница 3: ... Set Output operation Output mode and Unit Measurement Commence measurement on completion of setting Į Upper and lower threshold value setting Enter lower threshold value M1 upper threshold value M2 If key protect has been set make be to release key protect before operating the keys Please refer to KEY PROTECT FUNCTION for the procedure 9 Set to sensing mode The sensor will automatically enter the...

Страница 4: ...sensing mode after lower threshold value M1 and upper threshold value M2 have been set Since the values which have been set are stored in an EEPROM they are not erased even if the power supply is switched off Enter lower threshold value M1 The registered lower threshold value M1 appears and blinks The M1 setting indicator red and the pressure unit indicator red also blinks In the sensing mode pres...

Отзывы: