Key-protect is a function which prevents any unintentional
change in the conditions which have been entered in each
setting mode by making the sensor not to respond to the key
operations.
KEY-PROTECT FUNCTION
9
Setting of key-protect
࣭
࣭
In the sensing mode, press key contin-
uously until appears. (4 sec. approx.)
Once is displayed, release the key.
Then the key-protect is set and the sensor
enters into the sensing mode again.
MODE
Since the key-protect information is
stored in an EEPROM, it is not erased
even if the power supply is switched off.
Please take care to remember if the
key-protect function has been set.
࣭
࣭
Release of key-protect
࣭
࣭
In the sensing mode, press key contin-
uously until appears. (4 sec. approx.)
Once is displayed, release the key.
Then the key-protect is canceled and the
sensor enters into the sensing mode again.
MODE
When the keys are to be operated, make
sure that key-protect is released.
CONVERSION TABLE FOR PRES-
SURE UNITS
10
kPa
1
7.50062
1.01972
10
2
9.86923
10
㸫
3
1.01972
10
㸫
2
9.80665
10
㸫
3
7.35559
10
㸫
2
1
9.67841
10
㸫
5
1
10
㸫
4
1.33322
10
㸫
1
1
1.35951
10
1.31579
10
㸫
3
1.35951
10
㸫
3
9.80665
10
7.35559
10
2
1
10
4
9.67841
10
㸫
1
1
1.01325
10
2
7.60000
10
2
1.03323
10
4
1
1.03323
mmHg
(Torr)
atm
kgf/cm
2
mmH
2
O
1kPa
1mmHg
(1Torr)
1atm
1kgf/cm
2
1mmH
2
O
DIMENSIONS (Unit: mm)
11
3 digit LED
display (Red)
M1 setting
indicator (Red)
Pressure unit indicator
(mmH
2
O) (Red)
M2 setting
indicator (Red)
Operation
indicator (Orange)
Increment key
Decrement key
Mode selection
key
Pressure unit indicator
(kPa) (Red)
40
40
5.5
Pressure Lo-port
Pressure Hi-port
ȭ
3.7 cable 2m long
42.3
30
17
ȭ
4.6
ȭ
4.6
2-M3 female
threads 6 deep
25
32.5 10.6
13.6
Į
ە
Upper and lower threshold value setting
[lower threshold value (M1)] and [upper threshold value (M2)] of
the comparative outputs are set.
Set to lower threshold value (M1) set mode
The lower threshold value (M1) and the upper threshold value
(M2) can be entered in under the following conditions.
M1 < M2
No vacuum values
Set to sensing mode
࣭
Press key.
MODE
࣭
࣭
The sensor returns to sensing mode after
lower threshold value (M1) and upper
threshold value (M2) have been set.
Since the values which have been set are
stored in an EEPROM, they are not erased
even if the power supply is switched off.
Enter lower threshold value (M1)
࣭
The registered lower threshold value (M1)
appears and blinks. The M1 setting indicator
(red) and the pressure unit indicator (red) also
blinks.
࣭
In the sensing mode, press key.
MODE
Enter upper threshold value (M2)
Set to upper threshold value (M2) set mode
࣭
If set value M1 is larger than the registered
upper threshold value (M2), the sum of the
M1 value plus 1 digit appears and blinks.
Otherwise, the registered upper threshold
value (M2) appears and blinks. The M2
setting indicator (red) and the pressure unit
indicator (red) also blinks.
࣭
In the lower threshold value (M1) set mode,
press key.
MODE
The upper threshold value (M2) can be set to a value of lower
threshold value (M1) + 1 digit, or more, only.
If the output mode has been set to the window comparator
mode ( ) in the initial setting mode, lower threshold value (M1)
and upper threshold value (M2) should be set with a difference
of 3 digits (0.03 kPa.D {3 mmH
2
O.D}) or more.
࣭
࣭
࣭
࣭
Enter using key and key.
If key is pressed once, the set value
increases by 1 digit and if key is pressed
once, the set value decreases by 1 digit.
Further, if key or key is pressed
continuously, the set value changes quickly.
࣭
If the set pressure range is exceeded, either
(upper limit exceeded) or (lower
limit exceeded) is displayed.
࣭
Using key and key, enter in a manner
similar to that for entering lower threshold
value (M1).
࣭
If the set pressure range is exceeded, either
(upper limit exceeded) or (lower
limit exceeded) is displayed.
ە
ە
The models listed under “
SPECIFICATIONS
”
come with CE Marking.
As for all other models, please contact our office.
Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
1
INTENDED PRODUCTS FOR CE MARKING