26
HDD READ SEEK
Inspection
Inspecting seek time of HDD to inspect
performance.
At start
The [*] sign is added every 20
seconds while inspecting.
Two digits on the right side are the
progress level of the inspection
(The unit is %).
Example on the way of inspection:
When HDD is OK after inspection:
(NG is displayed when error is
excluding o )
(Transfer rate is calculated from the
AV scanning result, and when it is
less than 35Mbps, NG is displayed.)
$: [X] is displayed when seek time is
over 270msec., there is error or
transfer rate is NG.
Position at $ is space when
excluding those.
##: Number of data of over
100msec. and less than 270msec.
When it is over 100, [99] is
displayed.
When the number is less than 5, we
judge it normal.
Press [3] [1] in service mode.
* When canceling the inspection
mode while executing, do “forced
power-off”.
Method: Press [POWER] key more
than 10 seconds.
Item
FL Display
Key Operation
Mode Name
Description
(Remote controller key)
Содержание DMR-EH59GC
Страница 5: ...5 1 2 Caution for AC Cord For EH59GC only ...
Страница 14: ...14 ...
Страница 18: ...18 NOTE Use the replacement parts RMV0335 when the Sheet has not being stickability ...
Страница 35: ...35 9 2 P C B Positions ...
Страница 42: ...42 10 1 2 Checking and Repairing of RAM Digital P C B Module ...
Страница 43: ...43 10 1 3 Checking and Repairing of Main P C B ...
Страница 44: ...44 10 1 4 Checking and Repairing of HDD ...
Страница 90: ...90 14 1 6 Waveform Chart ...